Description
SLC611D POWERCELL® PDX Load Cell
The SLC611D POWERCELL® is approved for use in various applications in Europe, Asia, America and almost everywhere else in the world. If an approval is required, the SLC611D POWERCELL® already complies.

Tank Weighing
The capacity range from 7.5t to 22.5t allows the weighing of tanks and silos. The stainless steel design, hermetic sealing and IP68/IP69K protection provides the best reliability in tank and hopper weighing applications.
Load Cells
POWERCELL® load cells have a rocker-pin design that automatically aligns load forces for accurate weighing. These hermetically sealed load cells are rated IP68/IP69K and can be used in all environments.
PowerMountTM Weigh Module
The optional METTLER TOLEDO PowerMountTM weigh module allows one to convert an existing system into a precise weighing system. It is ideal for applications such as tanks scales, belt scales and conveyor scales. Available in zinc plated steel or stainless steel.
Predictive Maintenance
SLC611D monitors single load cells for overload, zero drift, foundation problems, etc.; prompting action before system shuts down or measures incorrectly.
| Parameter | Unit of Measure | Specification | ||||||||||||||
| Trade Name | POWERCELL PDX | |||||||||||||||
| Model Number | SLC820 | |||||||||||||||
| Load Cell Type | Column Compression, Digital Weight Processor (DWP) | |||||||||||||||
| Part Number | 42904882 | 42904883 | 42904884 | 42904885 | 42904891 | 42904892 | 30290638 | 72238150 | 72238147 | 30220694 | 30314022 | |||||
| Rated Capacity (R.C.)1 | t (klb, nominal) | 20 (44.1) | 30 (66.2) | 50 (110.3) | 90 (198.5) | 200 (440) | 300 (660) | |||||||||
| Sensitivity at R.C. | d @ R.C. | 200,000 | 300,000 | 500,000 | 900,000 | 200,000 | 300,000 | |||||||||
| Communication | Controller Area Network (CAN), Encrypted | |||||||||||||||
| Communication Rate | kbit/sec | 125 | ||||||||||||||
| Effective System Update Rate | Hz | 83 (with 4 cells), 50 (with 6 cells), 25 (with 14 cells), 15 (with 24 cells) | ||||||||||||||
| Effective System Synchronous Update Rate | Hz | 40 (with 10 cells) | ||||||||||||||
| Weighing Performance | ||||||||||||||||
| Effect of Cable Length on System Accuracy | kg | 0 (Digital Signal) | ||||||||||||||
| Compensated2 | °C (°F) | -10 to +40 (+14 to +104) | ||||||||||||||
| Temperature Range | Operating3 | °C (°F) | -50 to +55 (-58 to +131) | |||||||||||||
| Safe Storage | °C (°F) | -40 to +80 (-40 to +176) | ||||||||||||||
| Warm-up Time from Cold Start | minutes | 15 | ||||||||||||||
| Class | C3/IIIL-M | C3/IIIL-M | C4/IIIL-M | C6 | C3/IIIL-M | C4/IIIL-M | C6 | C3/IIIL-M | C4/IIIL-M | C1 | C1 | |||||
| Metrology | Linearity4 | ppm R.C. | < 100 | < 100 | < 100 | < 67 | < 100 | < 100 | < 67 | < 100 | < 100 | < 140 | < 140 | |||
| Hysteresis4 | ppm R.C. | < 160 | < 160 | < 160 | < 110 | < 160 | < 160 | < 110 | < 160 | < 160 | < 220 | < 220 | ||||
| Span4 | ppm R.C./°C | < ±13.3 | < ±13.3 | < ±10.0 | < ±6.6 | < ±13.3 | < ±10.0 | < ±6.6 | < ±13.3 | < ±10.0 | < ±26.7 | < ±26.7 | ||||
| Temperature Effect on | Combined Error4 | ppm R.C. | < 300 | < 300 | < 300 | < 200 | < 300 | < 300 | < 200 | < 300 | < 300 | < 800 | < 800 | |||
| Creep at R.C. 10s to 30m | ppm R.C. | < ±150 | < ±150 | < ±125 | < ±83 | < ±150 | < ±125 | < ±83 | < ±150 | < ±125 | < ±500 | < ±500 | ||||
| Zero Return After 30 min at R.C. | ppm R.C. | < ±150 | < ±150 | < ±125 | < ±83 | < ±150 | < ±125 | < ±83 | < ±150 | < ±125 | < ±500 | < ±500 | ||||
| Barometric Pressure Effect on Zero Load Output | kg/kPa | < ±0.95 | < ±0.93 | < ±0.93 | < ±0.93 | < ±1.5 | < ±1.5 | < ±1.5 | < ±2.4 | < ±2.4 | < ±7.7 | < ±11.3 | ||||
| Zero Balance | %R.C. @ 20°C | < ±0.2 | ||||||||||||||
| Temperature Effect on Minimum Dead Load Output | kg/°C | < ±0.8*Vmin(OIML)/5°C | ||||||||||||||
| Humidity Effect, Continuous 100% RH | kg | 0 (Hermetic Seal) | ||||||||||||||
| Nonrepeatability | ppm R.C. | < ±50 | < ±200 | |||||||||||||
| Metrological Approvals | ||||||||||||||||
| Standard | OIML R60 | |||||||||||||||
| Number | T8426; TC7579; T2206; R60/2000-NL1-09:08 | |||||||||||||||
| Class | C3 | C3 | C4 | C6 | C3 | C4 | C6 | C3 | C4 | C1 | C1 | |||||
| nmax (OIML) | 3000 | 3000 | 4000 | 6000 | 3000 | 4000 | 6000 | 3000 | 4000 | 1000 | 1000 | |||||
| Y | kg/kg | 8000 | 11,111 | 12,500 | 20,000 | 11,111 | 12,500 | 20,000 | 11,111 | 14,286 | 10,000 | 30,000 | ||||
| Vmin (OIML) | kg | 2.5 | 2.7 | 2.4 | 1.5 | 4.5 | 4 | 2.5 | 8.1 | 6.3 | 20 | 30 | ||||
| European/OIML Approval5 | pLC | 0.8 | ||||||||||||||
| Humidity Symbol | CH (Hermetic Seal) | |||||||||||||||
| Min. Dead Load | kg | 50 | ||||||||||||||
| Standard | NIST Handbook 44 | |||||||||||||||
| Number | NTEP 08-090 | |||||||||||||||
| Class | III L-M | |||||||||||||||
| nmax (HB44) | 10,000 | 5000 | ||||||||||||||
| NTEP Approval5 | Vmin (HB44) | kg (lb, nominal) | 0.95 (2.1) | 1.0 (2.2) | 0.93 (2.0) | – | 1.7 (3.8) | 1.55 (3.4) | – | 3.2 (7.1) | 2.4 (5.3) | 7.7 (17) | 11.3 (25) | |||
| Min. Dead Load | kg (lb, nominal) | 50 (110.3) | ||||||||||||||
| 1 R.C. = Rated or full capacity as specified on the data plate. 2 Certified according to approval agency or notified body (third party). 3 Operating temperatures below -40°C/-40°F require the load cell to be continuously powered. 4 The combined error of span, linearity error, and hysteresis will not exceed 80% of the error limits for OIML R60. OIML R60 C3 error limits are typically 60% tighter than the HB44 10K III L-M allowable tolerance. 5 See certificate for complete information. |
||||||||||||||||
| Part Number | 42904882 | 42904883 | 42904884 | 42904885 | 42904891 | 42904892 | 30290638 | 72238150 | 72238147 | 30220694 | 30314022 | |||||
| Rated Capacity (R.C.) | t (klb, nominal) | 20 (44.1) |
30 (66.2) | 50 (110.3) | 90 (198.5) | 200 (440) |
300 (660) |
|||||||||
| Electrical | ||||||||||||||||
| Connectors | Quick-Connect with Bayonet Lock, 5 Pins, Stainless Steel, Glass-to-Metal Seal, Laser Welded | |||||||||||||||
| Cable | Exterior Braided Stainless Steel Armor, PVC Chemically Resistant Jacket, 9mm O.D., 5 Conductors, Triple Shielded and Dual Drain Wires | |||||||||||||||
| Cable Length, Cell to Cell (typical) | m (ft, nominal) | 2 to 14 (6.5 to 46) | ||||||||||||||
| Cable Length, Home Run (typical) | m (ft, nominal) | 10 to 300 by 10 increments (33 to 984 by 33 increments) | ||||||||||||||
| Supply Voltage by Terminal (Regulated in the Load Cell) | Typical | V DC | 12 or 24 | |||||||||||||
| Minimum/Maximum | V DC | 7.5 / 28 | ||||||||||||||
| Lightning Protection6 Max. Tested (SAE ARP5412) | A | > 80,000 | ||||||||||||||
| Surge Protective Device | Integral | |||||||||||||||
| Insulation Resistance at 50VDC | MΩ | ≥ 2000 | ||||||||||||||
| Breakdown Voltage | V AC | ≥ 500 | ||||||||||||||
| Mechanical | ||||||||||||||||
| Spring Element | 17-4 PH Stainless Steel (magnetic) | 420 Stainless Ste | ||||||||||||||
| Enclosure | Electropolished 304 Stainless Steel, 1mm Wall Thickness, Laser Welded | |||||||||||||||
| Material | Low-Profile Receivers | 17-4 PH Forged and Machined Stainless Steel, Hardened | ||||||||||||||
| Anti-Rotation | Integral, 6-Point Hexagonal Mount | |||||||||||||||
| Type | Hermetic (submersible) | |||||||||||||||
| Protection | IP Rating | IP68 (1m – 7 days submersion), IP69K test reports on file | ||||||||||||||
| NEMA Rating | NEMA 6P (submersible) | |||||||||||||||
| Safe | %R.C. | 200 | 150 | |||||||||||||
| Load Limit | Ultimate | %R.C. | 300 | 200 | ||||||||||||
| Safe Dynamic Load | %R.C. | 70 | ||||||||||||||
| Fatigue Life at R.C. | Cycles | > 1,000,000 | ||||||||||||||
| Direction of Loading | Compression | |||||||||||||||
| Deflection at R.C., typical | mm (in) | 0.36 (0.014) |
0.51 (0.020) | 0.71 (0.028) | 1.02 (0.040) | – | ||||||||||
| Horizontal Restoring Force | %A.L./mm7 | 1.82 | 1.82 | 1.82 | 1.6 | 1.59 | ||||||||||
| Shipping Weight, nominal | kg (lb) | 3.0 (6.6) |
3.0 (6.6) | 3.2 (7.0) | 7.5 (16.6) | 12.8 (28.2) |
29 (63.9) |
|||||||||
| 6 Tested with an IND780 terminal and lightning protection kit by Lightning Technologies, Inc. (80,000A). 7 Percent of the vertical applied load (A.L.) per mm of horizontal displacement.Country of origin: Designed by METTLER TOLEDO in Switzerland and made in China. |
||||||||||||||||
| Part Number | 42904882 | 42904883 | 42904884 | 42904885 | 42904891 | 42904892 | 30290638 | 72238150 | 72238147 | 30220694 | 30314022 | |||||
| Rated Capacity (R.C.) | t (klb, nominal) | 20 (44.1) |
30 (66.2) | 50 (110.3) | 90 (198.5) | 200 (440) |
300 (660) |
|||||||||
| Hazardous Area | ||||||||||||||||
|
Agency | FM Approvals Ltd. | ||||||||||||||
| Certificate Number | FM17ATEX0023 | |||||||||||||||
| Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012, EN 60529:1991+A1:2000+A2:2013 | |||||||||||||||
| Gas Rating | II 2 G Ex ib IIB T4 Gb | |||||||||||||||
| Dust Rating | II 2 D Ex ib IIIC T130°C Db | |||||||||||||||
| IS Parameters | Power: Ui = 8.4V, Ii = 100mA, Pi = 0.84W, Ci = 27.5uF, Li = 17.7uH CANbus: Ui = 8.4V, Ii = 100mA, Pi = 0.84W, Ci = 27.5uF, Li = 0uH | |||||||||||||||
| Temperature Range | -40°C ≤ Ta ≤ +55°C | |||||||||||||||
| Installation Instructions | 30343366 | |||||||||||||||
| IECEx Zone 1/21 |
Agency | FM Approvals LLC | ||||||||||||||
| Certificate Number | IECEx FMG 17.0010 | |||||||||||||||
| Standards | IEC 60079-0:2011 Edition 6.0, IEC 60079-11:2011 Edition 6.0 | |||||||||||||||
| Gas Rating | Ex ib IIB T4 Gb | |||||||||||||||
| Dust Rating | Ex ib IIIC T130°C Db | |||||||||||||||
| IS Parameters | Power: Ui = 8.4V, Ii = 100mA, Pi = 0.84W, Ci = 27.5uF, Li = 17.7uH CANbus: Ui = 8.4V, Ii = 100mA, Pi = 0.84W, Ci = 27.5uF, Li = 0uH | |||||||||||||||
| Temperature Range | -40°C ≤ Ta ≤ +55°C | |||||||||||||||
| Installation Instructions | 30343366 | |||||||||||||||
| FM Division 1 Zone 1/21 |
Agency | FM Approvals LLC | ||||||||||||||
| Certificate Number | FM17US0025 | |||||||||||||||
| Standards | FM Class 3600:2011, FM Class 3610:2015, FM Class 3810:2005 ANSI/ISA 60079-0:2013, ANSI/ISA 60079-11:2014, ANSI/IEC 60529:2004 | |||||||||||||||
| Gas Rating | Class I, Division 1, Groups C, D, Temperature Class T4 Class 1, Zone 1, AEx ib IIB T4 Gb | |||||||||||||||
| Dust Rating | Class II, Division 1, Groups E, F, G, Temperature Class T4 Zone 21, AEx ib IIIC T130°C Db | |||||||||||||||
| Fiber Rating | Class III, Division 1 | |||||||||||||||
| IS Parameters | Power: Ui = 8.4V, Ii = 100mA, Pi = 0.84W, Ci = 27.5uF, Li = 17.7uH CANbus: Ui = 8.4V, Ii = 100mA, Pi = 0.84W, Ci = 27.5uF, Li = 0uH | |||||||||||||||
| Temperature Range | -40°C ≤ Ta ≤ +55°C | |||||||||||||||
| Control Drawing | 30343367 | |||||||||||||||
| CSA Division 1 Zone 1/21 |
Agency | FM Approvals LLC | ||||||||||||||
| Certificate Number | FM17CA0013 | |||||||||||||||
| Standards | CAN/CSA-C22.2 No. 60079-0:2015, CAN/CSA-C22.2 No. 60079-11:2014 CAN/CSA-C22.2 No. 61010-1:2012, CSA-C22.2 No. 60529:R2016 | |||||||||||||||
| Gas Rating | Class I, Division 1, Groups C, D, Temperature Class T4 Zone 1, Ex ib IIB T4 Gb | |||||||||||||||
| Dust Rating | Class II, Division 1, Groups E, F, G, Temperature Class T4 Zone 21, Ex ib IIIC T130°C Db | |||||||||||||||
| Fiber Rating | Class III, Division 1 | |||||||||||||||
| IS Parameters | Power: Ui (Vmax) = 8.4V, Ii (Imax) = 100mA, Pi = 0.84W, Ci = 27.5uF, Li = 17.7uH CANbus: Ui (Vmax) = 8.4V, Ii (Imax) = 100mA, Pi = 0.84W, Ci = 27.5uF, Li = 0uH | |||||||||||||||
| Temperature Range | -40°C ≤ Ta ≤ +55°C | |||||||||||||||
| Control Drawing | 30343367 | |||||||||||||||
| ATEX Zone 2/22 |
Agency | DEKRA Certification B.V. | – | – | ||||||||||||
| Certificate Number | KEMA 09ATEX0063 | – | – | |||||||||||||
| Standards | EN 60079-0:2012, EN 60079-15:2010, EN 60079-31:2014 | – | – | |||||||||||||
| Gas Rating | II 3 G Ex nA IIC T6 Gc | – | – | |||||||||||||
| Dust Rating | II 3 D Ex tc IIIC T85°C Dc IP6X | – | – | |||||||||||||
| Parameters | Power and CANbus: Umax = 26.4V, Imax = 2A, Pmax = 0.5W / Load Cell | – | – | |||||||||||||
| Temperature Range | -40°C ≤ Ta ≤ +55°C | – | – | |||||||||||||
| Installation Instructions | 61045275 | – | – | |||||||||||||
| IECEx Zone 2/22 |
Agency | DEKRA Certification B.V. | – | – | ||||||||||||
| Certificate Number | IECEx KEM 09.0028 | – | – | |||||||||||||
| Standards | IEC 60079-0:2011 Edition 6.0, IEC 60079-15:2010 Edition 4, IEC 60079-31:2008 Edition 1 | – | – | |||||||||||||
| Gas Rating | Ex nA IIC T6 Gc | – | – | |||||||||||||
| Dust Rating | Ex tc IIIC T85°C Dc IP6X | – | – | |||||||||||||
| Parameters | Power: Umax = 26.4V, Imax = 2A, Pmax = 0.5W / Load Cell | – | – | |||||||||||||
| Temperature Range | -40°C ≤ Ta ≤ +55°C | – | – | |||||||||||||
| Installation Instructions | 61045275 | – | – | |||||||||||||
| UL Division 2 |
Agency | Underwriters Laboratories Inc. | – | – | ||||||||||||
| Certificate Number | 2011-06-14-E152336 | – | – | |||||||||||||
| Standards | UL 508 Edition 17, ANSI/ISA 12.12.01-2007 | – | – | |||||||||||||
| Gas Rating | Class I, Division 2, Groups C, D | – | – | |||||||||||||
| Dust Rating | Class II, Division 2, Groups F, G | – | – | |||||||||||||
| Fiber Rating | Class III | – | – | |||||||||||||
| NIFW Parameters | Power: Vmax = 26.4V, Imax = 60mA, Ci = 11nF, Li = 0uH CANbus: Vmax = 26.8V, Imax = 4mA, Ci = 0.602nF, Li = 0uH | – | – | |||||||||||||
| Temperature Range | -40°C ≤ Ta ≤ +55°C | – | – | |||||||||||||
| Control Drawing | 42700274 | – | – | |||||||||||||
| CSA Division 2 |
Agency | Underwriters Laboratories Inc. | – | – | ||||||||||||
| Certificate Number | 2011-06-14-E152336 | – | – | |||||||||||||
| Standards | CAN/CSA-C22.2 No. 213-M1987 Edition 1, CAN/CSA-C22.2 No. 157-92, CAN/CSA-C22.2 No. 142-M1987 | – | – | |||||||||||||
| Gas Rating | Class I, Division 2, Groups C, D | – | – | |||||||||||||
| Dust Rating | Class II, Division 2, Groups F, G | – | – | |||||||||||||
| Fiber Rating | Class III | – | – | |||||||||||||
| NIFW Parameters | Power: Vmax = 26.4V, Imax = 60mA, Ci = 11nF, Li = 0uH CANbus: Vmax = 26.8V, Imax = 4mA, Ci = 0.602nF, Li = 0uH | – | – | |||||||||||||
| Temperature Range | -40°C ≤ Ta ≤ +55°C | – | – | |||||||||||||
| Control Drawing | 42700274 | – | – | |||||||||||||
SLC611D POWERCELL® Dimensional Drawings mm [in]

SLC611D POWERCELL® Order Information
| Item No., load cell | |
| Rated capacity | Class |
| C3/III M n:5 | |
| 7.5t | 30092515 |
| 15t | 30092516 |
| 22.5t | 30092517 |
Bolded entries are stocked
SLC611D POWERCELL® Home Run Cable
| Colour | Function |
| Yellow | Shield |
| Blue | CAN_L |
| White | CAN_H |
| Red | V + |
| Black | V – |
SLC611D POWERCELL® Order Information, Cables
| Item No. | ||||||||
| Description | Cable, material / length | |||||||
| PU / 3m (10ft) | PU / 5m (16.4ft) | PU / 10m (32.8ft) | PU / 20m (65.6ft) | PU / 30m (98.4ft) | PU / 50m (164ft) | PU / 100m (333ft) | PU / 150m (500ft) | |
| Cable kit, 3 load cells | 30302750 | 30302751 | 30302752 | 30302753 | – | – | – | – |
| Cable kit, 4 load cells | 30302754 | 30302755 | 30302756 | 30302757 | – | – | – | – |
| Load cell – load cell cable | 30302766 | 30302767 | 30302768 | 30302769 | – | – | – | – |
| Home Run Cable | – | 30302758 | 30302759 | 30302760 | 30302761 | 30302762 | 30302763 | 30302764 |
| Cable extension adapter | 30220628 | |||||||
| CAN termination load cell | 30302770 | |||||||
| Blind cap connector load cell | 30302771 | |||||||
| Cable gland for home run cable with IND780PDX | 30095639 | |||||||
Bolded entries are stocked