AEP transducers / F1 / Bending Beam Load Cell

Load cell suitable to work in hostile environments.
High mechanical resistance.
Completely made of stainless steel.
Completely LASER welded.
Degree of protection IP67.
Long term stability.

On request ATEX certificate (Zones 1 and 21) GAS and DUST

Description

BENDING BAEM load cell for the measurement of static and dynamic loads.

Nominal Load from 2,5 kg to 200 kg
Class (OIML R60) C2 and C3
Combined Error: 0,020%
Output: 2mV/V

 

Dimensions [mm]

CODE (C2) CODE (C3) LOAD
CF12K5C25 / 2.5 kg
CF15KC25 / 5 kg
CF110KC25 CF110KC35 10 kg
CF125KC25 CF125KC35 25 kg
CF150KC25 CF150KC35 50 kg
CF1100KC25 CF1100KC35 100 kg
CF1200KC25 CF1200KC35 200 kg

Technical Data

ACCURACY CLASS: OIML R60 C2 C3
LEGAL DIVISIONS 2000 3000
NOMINAL LOAD (Emax) 2.5 – 5 – 10 kg
25 – 50 kg
100 – 200 kg
10 kg
25 – 50 kg
100 – 200 kg
MIN. VERIFICATION INTERVAL (Vmin) Emax / 10000
COMBINED ERROR ± 0.026 % ± 0.020 %
NON-REPEATABILITY ± 0.012 % ± 0.010 %
ZERO RETURN over 30 min. ± 0.025 % ± 0.015 %
CREEP to nominal load:
a) over 30 min. ± 0.026 % ± 0.012 %
b) over 20 and 30 min. ± 0.010 % ± 0.009 %
TEMPERATURE EFFECT (10 °C)
a) on zero
b) on sensitivity
± 0.025 %
± 0.008 %
± 0.012 %
± 0.008 %
NOMINAL SENSITIVITY
SENSITIVITY TOLERANCE
2 mV/V
± 0.1 %
INPUT RESISTANCE 420 ± 20 Ω
OUTPUT RESISTANCE 350 ± 2 Ω
INSULATION RESISTANCE > 5 GΩ
ZERO BALANCE ± 1 %
RECOMMENDED SUPPLY VOLTAGE 10 V
NOMINAL SUPPLY VOLTAGE 1 – 15 V
MAXIMUM SUPPLY VOLTAGE 18 V
MECHANICAL LIMIT VALUES
REFERRED TO NOMINAL LOAD:
a) minimum load 0 %
b) service load 120 %
c) max permissible load 150 %
d) breaking load > 300 %
e) max transverse load 200 %
f) max permissible dynamic load
DISPLACEMENT AT NOMINAL LOAD
75 %
~ 0.4 mm
REFERENCE TEMPERATURE +23 °C
TEMPERATURE NOMINAL RANGE -10 / +40 °C
SERVICE TEMPERATURE -20 / +70 °C
STORAGE TEMPERATURE -20 / +80 °C
WEIGHT ~ 0.62 kg
PROTECTION CLASS (EN 60529)
EXECUTION MATERIAL
CABLE LENGTH
IP67
Stainless Steel
5 m
FIXING SCREWS:
a) diameter M8
b) resistance class 12.9
c) tightening torque 20 Nm

Acceleration of gravity g=9.80434 m/s2

Electrical Connections

Connected to the body of the load cell.

PVC 105°C shielded cable, Ø 5.2mm with 4 tinned Ø0.35mm2 conductors.

 

Shield connected to the body of the load cell.

 

 

Reviews

There are no reviews yet.

Be the first to review “AEP transducers / F1 / Bending Beam Load Cell”