AEP transducers / F3 / Bending Beam Load Cell

Load cell suitable to work in hostile environments
High mechanical resistance
Completely made of stainless steel
Completely LASER welded
Degree of protection IP68
Long term stability

Description

BENDING BAEM load cell for the measurement of static and dynamic loads

Nominal Load from 10 kg to 2 tons
Class (OIML R60) C2 and C3
Combined Error: 0,018%
Output: 2mV/V

Dimensions [mm]

CODE (C2) CODE (C3) LOAD
CF310KC25 / 10 kg
CF325KC25 / 25 kg
CF350KC25 CF350KC35 50 kg
CF3100KC25 CF3100KC35 100 kg
CF3200KC25 CF3200KC35 200 kg
CF3500KC25 CF3500KC35 500 kg
CF31TC25 CF31TC35 1 t
CF31T5C25 CF31T5C35 1.5 t
CF32TC25 CF32TC35 2 t

Technical Data

ACCURACY CLASS: OIML R60 C2 C3
LEGAL DIVISIONS 2000 3000
 
NOMINAL LOAD (Emax)
10 – 25 kg
50 – 100 kg
200 – 500 kg
1 – 1.5 – 2 t
50 – 100 kg
200 – 500 kg
1 – 1.5 – 2 t
MIN. VERIFICATION INTERVAL (Vmin) Emax / 10000
COMBINED ERROR ≤ ± 0.027 % ≤ ± 0.018 %
NON-REPEATABILITY ≤ ± 0.015 % ≤ ± 0.011 %
ZERO RETURN over 30 min. ≤ ± 0.021 % ≤ ± 0.015 %
CREEP to nominal load:
a) over 30 min. ≤ ± 0.028 % ≤ ± 0.012 %
b) over 20 and 30 min. ≤ ± 0.012 % ≤ ± 0.010 %
TEMPERATURE EFFECT (10 °C) ≤ ± 0.023 %
≤ ± 0.010 %
≤ ± 0.013 %
≤ ± 0.009 %
a) on zero
b) on sensitivity
NOMINAL SENSITIVITY
SENSIVITY TOLERANCE
2 mV/V
≤ ± 0.1 %
INPUT RESISTANCE 420 ± 20 W
OUTPUT RESISTANCE 350 ± 2 W
INSULATION RESISTANCE > 5 G W
ZERO BALANCE ≤ ± 1 %
RECOMMENDED SUPPLY VOLTAGE 10 V
NOMINAL SUPPLY VOLTAGE 1 – 15 V
MAXIMUM SUPPLY VOLTAGE 18 V
MECHANICAL LIMIT VALUES
REFERRED TO NOMINAL LOAD:
a) minimum load 0 %
b) service load 120 %
c) max permissible load 150 %
d) breaking load > 300 %
e) max transverse load 200 %
f) max permissible dynamic load
DISPLACEMENT AT NOMINAL LOAD
75 %
~ 0.4 mm
REFERENCE TEMPERATURE + 23 °C
TEMPERATURE NOMINAL RANGE -10 / +40 °C
SERVICE TEMPERATURE -20 / +70 °C
STORAGE TEMPERATURE -20 / +80 °C
WEIGHT ~ 1.0 kg
PROTECTION CLASS (EN 60529) EXECUTION MATERIAL
CABLE LENGTH
IP67
Acciaio Inox / Stainless Steel
5m
FIXING SCREWS:
a) diameter M12
b) resistance class 12.9
c) tightening torque 70 Nm

Acceleration of gravity g=9.80434 m/s2

Electrical Connections

 

*Connected to the body of the load cell.

Shield connected to the body of the load cell.

 

 