AEP transducers / DCV-TC4 / Amplified Force transducers

Force transducer suitable for material testing machines and  test benches in general.
High mechanical resistance.
Completely made of stainless steel.
Completely LASER welded.
Degree of protection IP40.
Long term stability.

Category:

Description

Force transducers for the measurement of static and dynamic loads in COMPRESSION and TENSION

Nominal Load from 10 kN to 1 MN
Linearity and Hysteresis 0.05%
INTEGRATED DIGITAL INDICATOR
ZERO adjustment

Load Display Ris.
0.5 t 0.5000 t 0.1 kg
1 t 1.000 t 1 kg
2.5 t 2.500 t 1 kg
5 t 5.000 t 1 kg
10 t 10.000 t 1 kg
20 t 20.000 t 1 kg
30 t 30.00 t 10 kg
50 t 50.00 t 10 kg
75 t 75.00 t 10 kg
100 t 100.00 t 10 kg

Dimensions[mm]

CODE LOAD ØA B C ØD ØE F G n° G H
CDCTC4100500K 0.5 t 100 86 35 72 32 M20X1.5 9 6 139
CDCTC41001T5M 1 t
CDCTC41002T5M 2.5 t
CDCTC41275T5M 5 t 127 110 35 92 47 M30X2 10.5 8 166
CDCTC412710T5M 10 t
CDCTC416520T5M 20 t 165 138 50 108 62 M42X3 17 12 204
CDCTC416530T5M 30 t
CDCTC416550T5M 50 t 60
CDCTC423075T5M 75 t 230 185 80 145 98 M60X3 25 12 269
CDCVTC4230100T5M 100 t


Technical Data

Accuracy £ ± 0.05% F.S.
NOMINAL LOAD 0.5-1-2.5 t 5-10 t 20-30 t 50 t 75-100 t
LINEARITY
HYSTERESIS
REPEATABILITY
≤ ±0.05% F.S.
≤ ±0.05% F.S.
≤ ±0.02% F.S.
INTERNAL RESOLUTION READINGS PER SEC. (0 filter) ±99999 div. 100 (10ms)
REFERENCE TEMPERATURE +23°C
TEMPERATURE NOMINAL RANGE -10/+40 °C
SERVICE TEMPERATURE -10/+70 °C
STORAGE TEMPERATURE -20/+80 °C
TEMPERATURE EFFECT (10°C)
a) on zero
b) on sensitivity
EFFECT OF TRANSVERSE LOAD:
a) at 10% of nominal load
≤ ±0.028% F.S.
≤ ±0.024% F.S.≤ ±0.030% F.S.
ZERO FUNCTION 100% F.S.
PROGRAMMABLE DIGITAL FILTER
PROGRAMMABLE RESOLUTION
PEAK FUNCTION
0¸5
1, 2, 5, 10, 20, 50, 100
Pos. (+), Neg. (-) or Disabled
RED DISPLAY (high efficiency) DISPLAY HEIGHT 7 segments
13 mm
RECOMMENDED POWER SUPPLY 10¸15Vdc
ABSOLUTE POWER SUPPLY 18Vdc overvoltage and overcurrent protected
MAX. ELECTRICAL INPUT 50mA
POWER CONNECTOR MIL PT02E10-6P
MECHANICAL LIMIT VALUES
REFERRED TO NOMINAL LOAD:
a) service load 120%
b) max permissible load 150%
c) breaking load >300%
d) max transverse load 50%
e) max permissible dynamic load 75% (1)
DISPLACEMENT AT NOMINAL LOAD ~0.06mm ~0.09mm ~0.17mm ~0.17mm ~0.23mm
WEIGHT ~1.60 kg ~2.45 kg ~5.80 kg ~6.80 kg ~16.5 kg
PROTECTION CLASS (EN 60529)
EXECUTION MATERIAL
CABLE LENGTH
IP40
Acciaio Inox / Stainless Steel
5m
FIXING SCREWS
a) diameter M8 M10 M16 M16 M24
b) resistance class 12.9 12.9 12.9 12.9 12.9
c) tightening torque 40 Nm 70 Nm 368 Nm 368 Nm 460 Nm

Tests and calibrations performed in COMPRESSION with the transducer mounted on a bearing support with correctly tightened clamping screws.
(1) The dynamic load must be applied to the transducer central thread and not to the external fixing rim.

Electrical Connections

MIL6M INPUT CABLE (optional)
A
B
F
POWER + (12Vdc)
POWER – (GND)
EARTH (1)
Red
Black
Shield

(1) Collegato al corpo del trasduttore. / Connected to the body of the transducer.