KIS-1 Load Cell/Weigh Module
Features
Capacity range: 50, 100, 200, 300, and 500kN (11.2K, 22.4K, 44.9K, 67.5K, and 112.4Klb)
Simple installation
Moveable load point
Withstands very high lateral forces
Extremely accurate and rugged
ATEX/IECEx/cFMus certified for hazardous locations
Application: Process Weighing & Batching,Strip & Web Tension,Hazardous Areas
Certificates: ATEX,IECEx,cFMus
Combined Error: 0-0.05 %
Environment Protection Class: IP67,IP66,IP65,IP54,IP20
Industry: Offshore,Metal,Mining,Pulp & Paper,Chemical,Pharmaceutical,Food & Beverage
Material: Stainless Steel,Plated Steel
Max Capacity: k lb: 25-115
Max Capacity: kN: 100-500
Max Capacity: ton: 10-50
Product Type: Weigh Modules & Load Cells,Force Transducers & Tension Measurement Modules
OUTLINE DIMENSIONS

| RANGE
kN (lb) |
ØA | ØB | ØC | D | E | F | G | H | J | K | L | ØM | N | P | R | S | T |
| 50
(11.2k) |
77
(3.03) |
75
(2.95) |
70
(2.76) |
288
(11.46) |
93
(3.66) |
65
(2.56) |
141.3
(5.56) |
12
(.47) |
5
(.20) |
2.65
(.10) |
2.65
(.10) |
9.1
(.36) |
14
(.55) |
7
(.28) |
110
(4.33) |
20
(.79) |
60
(2.36) |
| 100
(22.4k) |
92
(3.62) |
90
(3.54) |
82
(3.23) |
312
(12.40) |
107
(4.21) |
65
(2.56) |
155.4
(6.12) |
15
(.59) |
6
(.24) |
2.65
(.10) |
3.15
(.12) |
12.6
(.50) |
17
(.67) |
8
(.31) |
120
(4.72) |
20
(.79) |
70
(2.76) |
| 200
(44.9k) |
101
(3.98) |
100
(3.94) |
90
(3.54) |
343
(13.62) |
130
(5.04) |
65
(2.56) |
175.8
(6.92) |
15
(.59) |
6
(.24) |
3.15
(.12) |
3.15
(.12) |
15.7
(.62) |
19
(.75) |
8.5
(.33) |
128
(5.12) |
20
(.79) |
80
(3.15) |
| 300
(67.5k) |
101
(3.98) |
100
(3.94) |
90
(3.54) |
343
(13.62) |
130
(5.04) |
65
(2.56) |
175.8
(6.92) |
15
(.59) |
6
(.24) |
3.15
(.12) |
3.15
(.12) |
15.7
(.62) |
19
(.75) |
8.5
(.33) |
128
(5.12) |
20
(.79) |
80
(3.15) |
| 500
(112.4k) |
142
(5.59) |
140
(5.51) |
130
(5.12) |
447
(17.72) |
168
(6.50) |
75
(2.95) |
212.8
(8.38) |
35
(1.38) |
20
(.79) |
4.15
(.16) |
4.15
(.16) |
15.7
(.62) |
30
(1.18) |
8.5
(.33) |
177
(7.09) |
27
(1.06) |
80
(3.15) |
Dimension shown in mm (in)
OUTLINE DIMENSIONS cont

| RANGE
kN (lb) |
A | B | C | D | ØE | F | G | H | J | K | L | M | ØN | P | T | R | S |
| 50 (11.2k) | 280
(11.02) |
150
(5.91) |
30
(1.18) |
152
(5.98) |
16
(0.63) |
115
(4.53) |
245
(9.65) |
65
(2.56) |
45,5
(1.79) |
115
(4.53) |
150
(5.91) |
72
(2.83) |
18
(0.71) |
30
(1.18) |
30
(1.18) |
M16 M16 | 43
(1.69) |
| 100 (22.4k) | 310
(12.20) |
170
(6.69) |
40
(1.57) |
173
(6.81) |
22
(0.87) |
130
(5.12) |
270
(10.63) |
65
(2.56) |
63
(2.48) |
126
(4.96) |
160
(6.30) |
85
(3.35) |
22
(0.87) |
40
(1.57) |
26
(1.02) |
M20 M20 | 50
(1.97) |
| 200 (44.9k) | 340
(13.39) |
180
(7.09) |
50
(1.97) |
199
(7.83) |
25
(0.98) |
140
(5.51) |
300
(11.81) |
65
(2.56) |
71
(2.80) |
146
(5.75) |
190
(7.48) |
95
(3.74) |
25
(0.98) |
49
(1.97) |
32
(1.26) |
M24 M24 | 57
(2.24) |
| 300* (67.5k) | 340
(13.39) |
180
(7.09) |
50
(1.97) |
199
(7.83) |
25
(0.98) |
140
(5.51) |
300
(11.81) |
65
(2.56) |
71
(2.80) |
175
(6.89) |
220
(9.02) |
105
(4.13) |
26
(1.02) |
53
(2.09) |
32
(1.26) |
M24 M24 | 56
(2.20) |
| 500* (112.4k) | 480
(18.90) |
280
(11.02) |
60
(2.36) |
315
(12.40) |
33
(1.30) |
220
(8.66) |
420
(16.54) |
75
(2.95) |
108
(4.25) |
240
(9.45) |
300
(11.81) |
150
(5.91) |
26
(1.02) |
68
(2.76) |
60
(2.36) |
M24 M24 | 91
(3.58) |
| RANGE
kN (lb) |
V |
| 50 | M16-2X120 (4.724) LG |
| 100 | M20-2.5X140 (5.512) LG |
| 200 | M24-3X160 (6.299) LG |
| 300 | Not available |
| 500 | Not available |
Dimension shown in mm (in)
| SPECIFICATIONS | |
| PARAMETER | VALUE |
| PERFORMANCE | |
| Rated load (RL) | 50, 100, 200, 300, 500 kN |
| Combined error (terminal) | ±0.03% RO |
| Repeatability | 0.01% RO |
| Overload,* safe | 200% RL, 150% RL for 300 kN and 500 kN |
| Overload,* ultimate | 300% RL, 200% RL for 300 kN |
| Uplift, safe | 70% RL |
| Uplift, ultimate | 85% RL |
| Side load,* safe | 100% RL, 50% RL for 300 kN and 500 kN |
| Side load,* ultimate | 200% RL, 100% RL for 300 kN and 500 kN |
| Input voltage, recommended | 5-10 VDC or VAC |
| Input voltage, maximum | 18 VDC or VAC |
| Input resistance | 350 Ω ±3 Ω |
| Output resistance | 350 Ω ±0.5 Ω |
| Rated output (RO) | 2.040 mV/V |
| Tolerance of RO | ±0.1% RO |
| Zero balance | ±1% RO |
| Tolerance of shunt calibration values | 0.1% of value; actual output deined on unit calibration sheet |
| Creep at RL after 30 minutes | ±0.04% RL |
| Temperature range
(wider temperature range available upon request) |
–40 to +105°C
–40 to +220°F |
| Temperature effect, on output (–10°C to +50°C) | ±0.0015% of output/°C
±0.0008% of output/°F |
| Temperature effect, on zero balance (–10°C to +50°C) | ±0.003% RO/°C
±0.0017 % RO/°F |
| Insulation resistance at 200 VDC | >4 GΩ |
| Material: load cell, 50 kN | Stainless steel (Nobel version), yellow chromate steel (BLH version) |
| Material: load cell, 100–500 kN | Yellow chromate steel, stainless steel as an option |
| Material: bracket, yoke and tilt guard | Yellow chromate steel, stainless steel as an option |
| Electrical connection | 10m shielded four conductor cable |
| Degree of protection | IP67 |
| APPROVALS | |
| ATEX, IECEx and cFMus certiied versions are available upon request. | |
* Referring to recommended loading point
BLH Nobel is continually seeking to improve product quality and performance. Speciications may change accordingly.


Reviews