BLH NOBEL / KIS-2 Load Cell/Weigh Module

The KIS-2 load cell has several features that clearly distinguish it from other load cells. It is easy to install and extremely accurate, even when subjected to dynamic process forces and severe environmental conditions. Due to the double cantilever design it can have a floating load point and is not affected by side forces up to 100%. This makes it non sensitive to thermal expansions, vibrations and disturbant side force. All KIS load cells can be ATEX/IECEx/cFMus certified for use in explosive atmospheres.

Brand:

Description

KIS-2 Load Cell/Weigh Module

Features
Capacity range: 1, 2, 5, 10, 20, 30 and 50kN (225, 450, 1.12K, 2.25K, 4.5K, 6.75K, and 11.2Klb)
Simple installation
Moveable load point
Withstands very high lateral forces
Extremely accurate and rugged
ATEX/IECEx/cFMus certified for hazardous locations
Application: Process Weighing & Batching,Strip & Web Tension,Hazardous Areas
Certificates: ATEX,IECEx,cFMus
Combined Error: 0-0.05 %
Environment Protection Class: IP67,IP66,IP65,IP54,IP20
Industry: Offshore,Metal,Mining,Pulp & Paper,Chemical,Pharmaceutical,Food & Beverage
Material: Stainless Steel,Plated Steel
Max Capacity: k lb: 0-25
Max Capacity: kN: 0-100
Max Capacity: ton: 0-10
Product Type: Weigh Modules & Load Cells,Force Transducers & Tension Measurement Modules

OUTLINE DIMENSIONS

 

RANGE

kN

ØA ØB ØC D E F G H J K L ØM N P R S T
1-2-5 34

(1.34)

33

(1.30)

29

(1.14)

166

(6.54)

46

(1.81)

35

(1.38)

10

(0.39)

2.5

(0.10)

1.6

(0.06)

4.4

(0.17)

10

(0.39)

3

(0.12)

70

(2.75)

15

(0.59)

30

(1.18)

10-20-30 51

(2.00)

50

(1.97)

45

(1.77)

210

(8.27)

60

(2.36)

55

(2.16)

97.85

(3.85)

13

(0.51)

4

(0.16)

1.85

(0.07)

2.15

(0.08)

7.5

(0.29)

12

(0.47)

4

(0.16)

75

(2.95)

20

(0.79)

46

(1.81)

50 77

(3.03)

75

(2.95)

70

(2.76)

288

(11.34)

95

( 3.74)

65

(2.56)

141.3

(5.56)

12

(0.47)

5

(0.20)

2.65

(0.10)

2.65

(0.10)

9.1

(0.36)

12

( 0.47)

8.5

(0.33)

108

(4.25)

20

(0.79)

60

(2.36)

Dimension shown in mm (in)

Weigh Module

OUTLINE DIMENSIONS cont.

RANGE KN A B C D ØE F G H J K L M ØN P T R S
1-2-5 175

(6.89)

75

(2.95)

14

(0.55)

81

(3.19)

12

(0.47)

51

(2.01)

151

(5.94)

35

(1.38)

31

(1.22)

55

(2.17)

70

(2.76)

41

(1.61)

8.5

(0.33)

19

(0.75)

14

(0.55)

M8 19

(0.75)

10-20-30 204

(8.03)

100

(3.93)

19

(0.75)

107.5

(4.23)

12

(0.47)

76

(2.99)

180

(7.08)

55

(2.16)

32

(1.26)

75

(2.95)

100

(3.93)

54

(2.12)

11

(0.43)

19

(0.75)

14

(0.55)

M10 27

(1.06)

50 280

(11.02)

150

(5.90)

30

(1.18)

152

(5.98)

16

(0.63)

115

(4.53)

245

(9.64)

65

(2.56)

45.5

(1.79)

115

(4.53)

150

(5.90)

72

(2.83)

18

(0.71)

29

(1.14)

30

(1.18)

M16 43

(1.69)

RANGE KN V
1-2-5 M8-1.25X70 (2.755) LG
10-20-30 M10-1.5X90 (3.543) LG
50 M16-2X120(4.724) LG

Dimension shown in mm (in)

Weigh Module

SPECIFICATIONS
PARAMETER  
PERFORMANCE
Rated load (RL) 1, 2, 5, 10, 20, 30, 50 kN
Combined error (terminal) ±0.05% RO
Repeatability 0.01% RO
Overload,* safe 200% RL, 150% RL for 30 kN and 50 kN
Overload,* ultimate 300% RL, 200% RL for 30 kN and 50 kN**
Uplift, safe 100% RL
Uplift, ultimate 120% RL
Side load,* safe 100% RL, 50% RL for 30 kN
Side load,* ultimate 200% RL, 100% RL for 30 kN
Input voltage, recommended 10 VDC or VAC
Input voltage, maximum 18 VDC or VAC
Input resistance 350 Ω ±3 Ω
Output resistance 350 Ω ±3 Ω
Rated output (RO) 2.040 mV/V
Tolerance of RO ±0.25% RO
Zero balance ±5% RO
Tolerance of shunt calibration values ±0.25% of value
Creep at RL after 30 minutes ±0.03% RL
Temperature range

(wider temperature range available upon request

–40 to +105°C

–40 to +212°F

Temperature effect, on output (–10°C to +50°C) ±0.0033% of output/°C

±0.00018% of output/°F

Temperature effect, on zero balance (–10°C to +50°C) ±0.0014% of RO/°C

±0.0008% of RO/°F

Insulation resistance at 200 VDC >4 GΩ
Material: Load cell Stainless steel
Material bracket, yoke and tilt guard Yellow chromate steel, stainless steel as an option
 

Electrical connection

10 m shielded four conductor cable (BLH version)
5 m shielded four conductor cable (Nobel version)
Degree of protection IP67

*  Referring to recommended loading point.
** 50 kN BLH version only.
BLH Nobel is continually seeking to improve product quality and performance. Speciications may change accordingly.

Reviews