BLH NOBEL / KIS-8 Load Cell/Weigh Module

The KIS-8 load cell has several features that distinguish it from other load cells. It is easy to install and extremely accurate, even when subjected to disruptive industrial forces and harsh environmental conditions. All KIS load cells can be cFMus, ATEX and IECEx certiied for use in explosive atmospheres.

Brand:

Description

KIS-8 Load Cell/Weigh Module

FEATURES

• Capacity range: 1, 2, 5, 10, 20, 30, 50, 100, and 200 kN (225, 450, 1.12K, 2.25K, 4.5K, 6.75K, 11.2K, 22.4K, and 44.9K lb)
• Easy installation
• Moveable load point
• Withstands very high lateral forces
• Extremely accurate and rugged
• cFMus, ATEX and IECEx certiied for hazardous locations

APPLICATIONS
• Silo/bin/hopper inventory weighing systems
• Mixing and blending tanks
• Force measurement systems
• Conveyors

OUTLINE DIMENSIONS

RANGE kN A1 A2 A3 A4 A5 A6 A7 B1 B2 B3 B4 B5 C ØD E F G
1–2 175 151 12 31 31 19 -6 75 70 51 55 48 14 33 54 39 78
5–10–20–30 204 180 12 32 50 19 21 100 100 76 75 73 12 50 56 53 79
50 280 245 17.5 46.5 65 28 21 150 150 115 115 97 14 75 72 72 97
100 310 270 20 63 65 40 22 170 160 130 126 118 15 90 78 88 108
200 340 300 20 71 65 50 37 180 190 140 146 132 16 100 92 96 128
RANGE kN H1 H2 H3 H4 H5 H6 H7 I J ØK L ØM P Circlip (2x) R S
1–2 81 14 67 41 48 27.5 14 22 30 8.5 M6 x 60 11 16 32 x 1.5 M8 19
5–10–20–30 107.5 18 89.5 54 68 38.5 18 26.5 77 11 M10 x 80 12 11.5 50 x 2 M10 27
50 152 28 124 72 94 54.5 28 36 98 18 M12 x 110 15 17 75 x 2.5 M16 43
100 173 28 145 85 108 65 38 57 96 22 M16 x 140 22 17 90 x 3 M20 50
200 199 36 163 95 118 72 48 80 96 25 M20 x 150 25 17 100 x 3 M24 57

Weigh Module

INSTALLATION EXAMPLES

Parameter Value
Rated load (RL) 1, 2, 5, 10, 20, 30, 50, 100, 200 kN
Creep at RL after 30 minutes ±0.03% RL
Combined error (terminal) ±0.075% RO
Temperature range –40 to +80 °C (+100 °C)(3)
Repeatability 0.02% RO
Temperature effect on output (–10 °C to +50 °C) ±0.003% of output / °C
Safe load 150% RL (1)
Ultimate load 200% RL (1)
Temperature effect on zero balance (–10 °C to +50 °C) ±0.003% of RO / °C
Ultimate sideload 100% RL (1)
Input voltage, recommended 5–10 VDC or VAC
Insulation resistance at 200 VDC > 4 GΩ
Input voltage, maximum 18 VDC or VAC
Material Stainless steel
Input resistance 350 Ω ±5 Ω
Electrical connection 5 m shielded four conductor cable (1–20 kN)
10 m shielded four conductor cable (50–200 kN)
Output resistance 350 Ω ±0.5 Ω
Rated output (RO) 2.040 mV/V
Tolerance of RO ±0.25% RO
Degree of protection IP67
Zero balance ±2% RO
Tolerance of shunt calibration values ±0.25% of value (2)
Approvals FM, ATEX, IECEx certified versions available upon request
  • Referring to recommended loading point
  • See calibration sheet of the load cell
  • –40 to +100°C on demand

BLH Nobel is continually seeking to improve product quality and performance. Speciications may change accordingly.

 

 

Reviews

There are no reviews yet.

Be the first to review “BLH NOBEL / KIS-8 Load Cell/Weigh Module”