Description
KIS-8 Load Cell/Weigh Module
FEATURES
• Capacity range: 1, 2, 5, 10, 20, 30, 50, 100, and 200 kN (225, 450, 1.12K, 2.25K, 4.5K, 6.75K, 11.2K, 22.4K, and 44.9K lb)
• Easy installation
• Moveable load point
• Withstands very high lateral forces
• Extremely accurate and rugged
• cFMus, ATEX and IECEx certiied for hazardous locations
APPLICATIONS
• Silo/bin/hopper inventory weighing systems
• Mixing and blending tanks
• Force measurement systems
• Conveyors
OUTLINE DIMENSIONS

| RANGE kN | A1 | A2 | A3 | A4 | A5 | A6 | A7 | B1 | B2 | B3 | B4 | B5 | C | ØD | E | F | G |
| 1–2 | 175 | 151 | 12 | 31 | 31 | 19 | -6 | 75 | 70 | 51 | 55 | 48 | 14 | 33 | 54 | 39 | 78 |
| 5–10–20–30 | 204 | 180 | 12 | 32 | 50 | 19 | 21 | 100 | 100 | 76 | 75 | 73 | 12 | 50 | 56 | 53 | 79 |
| 50 | 280 | 245 | 17.5 | 46.5 | 65 | 28 | 21 | 150 | 150 | 115 | 115 | 97 | 14 | 75 | 72 | 72 | 97 |
| 100 | 310 | 270 | 20 | 63 | 65 | 40 | 22 | 170 | 160 | 130 | 126 | 118 | 15 | 90 | 78 | 88 | 108 |
| 200 | 340 | 300 | 20 | 71 | 65 | 50 | 37 | 180 | 190 | 140 | 146 | 132 | 16 | 100 | 92 | 96 | 128 |
| RANGE kN | H1 | H2 | H3 | H4 | H5 | H6 | H7 | I | J | ØK | L | ØM | P | Circlip (2x) | R | S |
| 1–2 | 81 | 14 | 67 | 41 | 48 | 27.5 | 14 | 22 | 30 | 8.5 | M6 x 60 | 11 | 16 | 32 x 1.5 | M8 | 19 |
| 5–10–20–30 | 107.5 | 18 | 89.5 | 54 | 68 | 38.5 | 18 | 26.5 | 77 | 11 | M10 x 80 | 12 | 11.5 | 50 x 2 | M10 | 27 |
| 50 | 152 | 28 | 124 | 72 | 94 | 54.5 | 28 | 36 | 98 | 18 | M12 x 110 | 15 | 17 | 75 x 2.5 | M16 | 43 |
| 100 | 173 | 28 | 145 | 85 | 108 | 65 |
38 | 57 | 96 | 22 | M16 x 140 | 22 | 17 | 90 x 3 | M20 | 50 |
| 200 | 199 | 36 | 163 | 95 | 118 | 72 | 48 | 80 | 96 | 25 | M20 x 150 | 25 | 17 | 100 x 3 | M24 | 57 |
Weigh Module
INSTALLATION EXAMPLES
| Parameter | Value |
|---|---|
| Rated load (RL) | 1, 2, 5, 10, 20, 30, 50, 100, 200 kN |
| Creep at RL after 30 minutes | ±0.03% RL |
| Combined error (terminal) | ±0.075% RO |
| Temperature range | –40 to +80 °C (+100 °C)(3) |
| Repeatability | 0.02% RO |
| Temperature effect on output (–10 °C to +50 °C) | ±0.003% of output / °C |
| Safe load | 150% RL (1) |
| Ultimate load | 200% RL (1) |
| Temperature effect on zero balance (–10 °C to +50 °C) | ±0.003% of RO / °C |
| Ultimate sideload | 100% RL (1) |
| Input voltage, recommended | 5–10 VDC or VAC |
| Insulation resistance at 200 VDC | > 4 GΩ |
| Input voltage, maximum | 18 VDC or VAC |
| Material | Stainless steel |
| Input resistance | 350 Ω ±5 Ω |
| Electrical connection | 5 m shielded four conductor cable (1–20 kN) |
| 10 m shielded four conductor cable (50–200 kN) | |
| Output resistance | 350 Ω ±0.5 Ω |
| Rated output (RO) | 2.040 mV/V |
| Tolerance of RO | ±0.25% RO |
| Degree of protection | IP67 |
| Zero balance | ±2% RO |
| Tolerance of shunt calibration values | ±0.25% of value (2) |
| Approvals | FM, ATEX, IECEx certified versions available upon request |
- Referring to recommended loading point
- See calibration sheet of the load cell
- –40 to +100°C on demand
BLH Nobel is continually seeking to improve product quality and performance. Speciications may change accordingly.


65
Reviews
There are no reviews yet.