BLH NOBEL / KIMD-M Weigh Module

The model KIMD-M load cell is a double shear beam load cell, ideally suited for applications in harsh environments. Due to the special heavy duty design with moveable load point, the KIMD-M load cell is insensitive against side loading and other interfering effects such as thermal expansion. With high temp cable option, load cell is suitable for use in steel mills and foundries. Due to the high repeatability and high long-term stability, the load cell supplies very good results, even after perennial use. IP67 gives an excellent protection against dust and moisture. All KIMD load cells can be ATEX/IECEx certified for use in explosive atmospheres

Category:
Brand:

Description

KIMD-M Weigh Module

Features
High accuracy
Easy installation
For harsh environmental conditions
ATEX/IECEx approved for hazardous areas
Movable load point
Allow movement caused by thermal expension
No extra mounting
High capacity 500 – 1000kN and 1500 – 2000kN
Application: Process Weighing & Batching,Hazardous Areas
Certificates: ATEX,IECEx
Combined Error: 0.06-0.1 %
Environment Protection Class: IP67,IP66,IP65,IP54,IP20
Industry: Metal,Mining,Chemical,Pharmaceutical,Food & Beverage
Material: Stainless Steel,Plated Steel
Max Capacity: k lb: 115-450
Max Capacity: kN: 500-2000
Max Capacity: ton: 50-200
Product Type: Weigh Modules & Load Cells

CONFIGURATION

Weighing Module

OUTLINE DIMENSIONS (IN MILLIMETERS)

500–1000 kN Capacities:

1500–2000 kN Capacities:

Weighing Module

SPECIFICATIONS

Parameter Value
GENERAL PERFORMANCE
Rated load (RL) 500 / 1000 / 1500 / 2000 kN
Combined error (terminal) ±0.1% RO
Repeatability 0.02% RO
Rated output (RO) 0.9 mV/V
Tolerance of RO ±0.25% RO
Zero balance ±2% RO
Creep at RL after 30 min ±0.03% RL
LOADING
Safe load* 200% RL
Ultimate load* 300% RL
ELECTRICAL
Input voltage (recommended) 10 VDC or VAC
Input voltage (maximum) 18 VDC or VAC
Input resistance 350 Ω ±5 Ω
Output resistance 350 Ω ±0.5 Ω
Tolerance of shunt calibration values ±0.25% of value (actual output listed on unit calibration sheet)
Insulation resistance at 200 VDC >4 GΩ
Electrical connection 10 m shielded four-conductor cable
TEMPERATURE
Operating temperature range –40 to +80 °C (–40 to +100 °C on request)
Temperature effect on output (–10 to +50 °C) ±0.005% of output / °C
Temperature effect on zero balance (–10 to +50 °C) ±0.005% of RO / °C
MECHANICAL / PROTECTION
Material Yellow chromate steel
Degree of protection IP67

* Referring to recommended loading point
BLH Nobel is continually seeking to improve product quality and performance. Speciications may change accordingly.

Reviews

There are no reviews yet.

Be the first to review “BLH NOBEL / KIMD-M Weigh Module”