Features
Capacity 5, 10 and 20 kN
Withstand high overload
Robust design with low deflection
Small dimensions and easy installation
Application: Strip & Web Tension
Combined Error: 0.06-0.1 %
Environment Protection Class: IP67,IP66,IP65,IP54,IP20
Industry: Pulp & Paper
Material: Stainless Steel
Max Capacity: k lb: 0-25
Max Capacity: kN: 0-100
Max Capacity: ton: 0-10
Product Type: Weigh Modules & Load Cells,Force Transducers & Tension Measurement Modules

OUTLINE DIMENSIONS

Web Tension Transducer

INSTALLATION EXAMPLE

SPECIFICATIONS 

Parameter Value
GENERAL PERFORMANCE
Rated load (RL) 10 and 20 kN
Combined error (terminal) ±0.1% RO
Repeatability 0.02% RO
Rated output (RO) 1.020 mV/V
Tolerance of RO ±0.25% RO
Zero balance ±2% RO
LOADING
Overload, safe 100% RL (1)
Overload, ultimate 200% RL (1)
ELECTRICAL
Input voltage (recommended) 10 VDC or VAC
Input voltage (maximum) 18 VDC or VAC
Input resistance 382 Ω ±3 Ω
Output resistance 350 Ω ±3 Ω
Insulation resistance at 200 VDC >4 GΩ
Electrical connection 5 m shielded four-conductor cable
TEMPERATURE
Temperature range –40 to +80°C (+100°C) (2)
Temperature effect on output (–10°C to +50°C) ±0.005% of output/°C
Temperature effect on zero balance (–10°C to +50°C) ±0.005% of RO/°C
MECHANICAL / PROTECTION
Material Stainless steel
Degree of protection IP67

(1) For load perpendicular to the transducer
(2) –40 to +100°C on demand BLH Nobel is continually seeking to improve product quality and performance. Specifications may change accordingly.