Description
SEB Single-Ended Beam
FEATURES
- Capacities: 500 kg, 1 t, 1.5 t, 2 t, 2.5 t
- High side-load tolerance
- Electroless nickel-plated alloy tool steel
- OIML C3 approval (500 kg ~ 2.5 t)
- Optional – FM approval available
APPLICATIONS
- Truck / Rail scales
- Silo / Hopper / Tank weighing
- Platform scales (multiple load cells)
- Pallet truck scales
- Packaging machines
OUTLINE DIMENSIONS

| Capacity | Unit | L | L1 | L2 | L3 | W | W1 | H | D | T |
|---|---|---|---|---|---|---|---|---|---|---|
| 500 kg / 1 t / 1.5 t / 2 t | mm | 130.0 | 25.4 | 76.2 | 12.7 | 38.1 | 31.2 | 31.2 | 13.5 | M12 × 1.75 |
| 500 kg / 1 t / 1.5 t / 2 t | inch | 5.12 | 1.00 | 3.00 | 0.50 | 1.50 | 1.25 | 1.25 | 0.53 | — |
| 2.5 t | mm | 171.5 | 38.1 | 95.3 | 19.0 | 44.2 | 38.1 | 38.1 | 19.8 | M20 × 1.5 |
| Category | Parameter | Value | Unit |
|---|---|---|---|
| APPROVAL | NTEP/OIML Accuracy Class | C3 | – |
| METROLOGY | Maximum No. of Intervals (n) | 3000 | – |
| Y = Emax / Vmin | 10000 | – | |
| CAPACITY | Standard Capacities (Emax) | 500, 1000, 1500, 2000, 2500 | kg |
| PERFORMANCE | Rated Output (R.O.) | 3.0 | mV/V |
| Rated Output Tolerance | ±0.25 | % of RO | |
| Zero Balance | ±1 | % of RO | |
| Non-linearity | ±0.025 | % of RO | |
| Hysteresis | ±0.025 | % of RO | |
| Non-repeatability | ±0.020 | % of RO | |
| Creep Error (20 min) | ±0.030 | % of RO | |
| Zero Return (20 min) | ±0.030 | % of RO | |
| TEMP. EFFECT | Temp. Effect on Min. Dead Load Output | ±0.0014 | % of RO / °C |
| Temp. Effect on Sensitivity | ±0.0008 | % of Load / °C | |
| TEMPERATURE | Compensated Range | –10 to +40 | °C |
| Operating Range | –20 to +60 | °C | |
| LOAD RATING | Safe Overload | 150 | % of R.C. |
| Ultimate Overload | 300 | % of R.C. | |
| ELECTRICAL | Excitation (Recommended) | 10 | VDC / VAC RMS |
| Excitation (Maximum) | 15 | VDC / VAC RMS | |
| Input Impedance | 385 ±5 | Ω | |
| Output Impedance | 350 ±3 | Ω | |
| Insulation Resistance | >5000 | MΩ | |
| CONSTRUCTION | Material | Nickel-plated alloy steel | – |
| PROTECTION | Environmental Protection | IP67 | – |
All speciications subject to change without notice.
FM Approval
Intrinsically Safe: Class I, II, III; Div. 1 Groups A-G
Non-Incendive: Class I; Div. 2 Groups A-D