Description
HOC High Capacity Off-Center Single-Point Load Cell
FEATURES
- Capacities: 750, 1000, and 2000 kg
- Fully sealed for water resistance
- Side mount construction
- Anodized aluminum alloy
- OIML C3 approval
- Platform size: 48” x 48” / 120 cm x 120 cm
- Optional – FM approval available
APPLICATIONS
- Platform scales (single load cell)
- Packaging machines
- Dosing / Filling
- Belt scales / Conveyor scales
OUTLINE DIMENSIONS

| CAPACITY (kg) | L | L1 | W | W1 | H | H1 | H2 | T | |
| 750/1000/2000 | mm | 176.0 | 134.5 | 76.0 | 46.0 | 125.0 | 95.0 | 45.0 | M16 x 2.0 |
| (inch) | 6.93 | 5.30 | 2.99 | 1.81 | 4.92 | 3.74 | 1.77 |
SPECIFICATIONS
| PARAMETER | VALUE | UNIT | |
| NTEP/OIML accuracy class | Non-Approved | C3 | |
| Maximum no. of intervals (n) | 1000 | 3000 | |
| Y = Emax/Vmin | 5000 | 10000 | Maximum available |
| Standard capacities (Emax) | 750, 1000, 2000 | kg | |
| Rated output—R.O. | 2.0 | mV/V | |
| Rated output tolerance | 10 | ±% of rated output | |
| Zero balance | 1 | ±% of rated output | |
| Non-linearity | 0.020 | 0.015 | ±% of rated output |
| Hysteresis | 0.020 | 0.015 | ±% of rated output |
| Non-repeatability | 0.020 | ±% of rated output | |
| Creep error (20 minutes) | 0.030 | 0.020 | ±% of rated output |
| Zero return (20 minutes) | 0.030 | 0.020 | ±% of rated output |
| Temperature effect effect on min. dead load output | 0.0026 | 0.014 | ±% of rated output/°C |
| Temperature effect on sensitivity | 0.0015 | 0.008 | ±% of applied load/°C |
| Compensated temperature range | –10 to +40 | °C | |
| Operating temperature range | –20 to +60 | °C | |
| Safe overload | 150 | % of R.C. | |
| Ultimate overload | 200 | % of R.C. | |
| Excitation, recommended | 10 | VDC or VAC RMS | |
| Excitation, maximum | 15 | VDC or VAC RMS | |
| Input impedance | 410±10 | Ω | |
| Output impedance | 350±3 | Ω | |
| Insulation resistance | >5000 | MΩ | |
| Construction | Anodized aluminum | ||
| Environmental protection | IP66 | ||
NOTES
- All specifications subject to change without notice.
FM APPROVAL
- Intrinsically Safe: Class I, II, III; Div. 1 Groups A–G
- Non-Incendive: Class I; Div. 2 Groups A–D


Reviews
There are no reviews yet.