scaime / SK30X 2T Shear beam Load cell

  • Stainless steel construction, hermetically welded to IP68
  • 6 000 d OIML R60 and 5 000 d NTEP approved
  • Current calibrated signal output, for multi-load cells mounting
  • Ideally suited for platform scales
Brand:

Description

SK30X 2T Shear beam Load cell

Function Wire Color (FR) Wire Color (EN)
Excitation (+) Marron Brown
Signal (+) Jaune Yellow
Signal (−) Blanc White
Excitation (−) Vert Green
Sense (+) Gris Grey
Sense (−) Rose Pink

Specifications

METROLOGICAL C3 12e C3 10e C6 15e
Rated capacity (Cn) 300 500, 1 000, 2 000 500, 1 000, 2 000 kg
Combined error ±0.017 ±0.008 %Cn
Temperature effect on zero ±0.0012 ±0.0014 ±0.0009 %Cn/°C
Temperature effect on sensitivity ±0.0014 ±0.0007 %Cn/°C
Creep error (30 min.) ±0.024 ±0.012 %Cn

LEGAL METROLOGY OIML R60

Accuracy class C3 C6
Maximum capacity (Emax) 300, 500, 1 000, 2 000 500, 1 000, 2 000 kg
Max. number of LC intervals (nmax) 3 000 6 000 d OIML
Minimum verification interval (vmin) Emax/12 000 Emax/10 000 Emax/15 000 kg
Z=Emax/(2xDR) 3 000 6 000
ELECTRICAL
Nominal range of excitation voltage 1 … 15 V
Rated output at Cn 2 mV/V
Current adjustement ±0.1 %Cn
Zero balance ±10 %Cn
Input/output resistance 385 ±20 / 350 ±5 Ω
Insulation resistance 5 000 MΩ/50V
GENERAL
Compensated temperature range -10 … +40 °C
Service temperature range -20 … +60 °C
Safe load limit 150 %Emax
Ultimate overload 200 %Emax
Tightening torque 30 Nm
Protection class IP68 EN 60529
Material

Measuring body

 

Acier inox – Stainless steel

Cable sheath PVC
Cable length 5 m
Net weight 940 g

Options

Category Protection Type Temperature Class Protection Level Ambient Temperature Zone
II 1 G/D Ex ia IIC Ga / Ex ia IIIC Da T6 / T80 °C IP6X −20 °C to +60 °C Zone 0 / 20
II 1 D Ex ta IIIC Da T125 °C IP6X −20 °C to +60 °C Zone 20
II 3 G Ex nA IIC Gc T6 −20 °C to +60 °C Zone 2

Reviews

There are no reviews yet.

Be the first to review “scaime / SK30X 2T Shear beam Load cell”