Description
S-Type load cells Type WSY
S-Type load cells are standard for industrial applications. They are used for measurement of tension and/or compression. Force indroduction happens via swivel heads. The force transducers adjust themselves if they have enough freedom. As a consequence measurement is very accurate.

| Nominal Load | Output Signal | Order Number |
|---|---|---|
| 50 – 250 kg | 2 mV/V ± 0.1 % | On request |
| 500 kg | 2 mV/V ± 0.004 | WSY-500kg-m202 |
| 1000 kg | 2 mV/V ± 0.004 | WSY-001to-m202 |
| 2000 kg | 2 mV/V ± 0.004 | WSY-002to-m202 |
| 3000 kg | 2 mV/V ± 0.004 | WSY-003to-m202 |
| 4000 kg | 2 mV/V ± 0.004 | WSY-004to-m202 |
| 5000 kg | 2 mV/V ± 0.004 | WSY-005to-m202 |
| 7500 kg | 2 mV/V ± 0.004 | WSY-750dkg-m202 |
| 10000 kg | 2 mV/V ± 0.1 % | On request |
| Nominal Load | W (mm) | H (mm) | Thread |
|---|---|---|---|
| 500 / 1000 kg | 32 | 25 | M12 × 1.75 |
| 2000 / 3000 kg | 32 | 25 | M20 × 1.5 |
| 4000 kg | 36 | 25 | M20 × 1.5 |
| 5000 / 6000 / 7500 kg | 50 | 24 | M24 × 2 |
Technical Data
| Technical Data | Specification |
|---|---|
| Nominal Load (Fnom) | 500 / 1000 / 2000 / 3000 / 4000 / 5000 / 6000 / 7500 kg |
| Limit Load | 150 % |
| Breaking Load | 300 % |
| Accuracy | 0.023 % F.S. |
| Creep (20 min) | 0.016 % F.S. |
| Output Signal | 2.0 mV/V ± 0.004 |
| Optional Outputs | 4…20 mA or 0…10 V (with optional in-line amplifier) |
| Input Resistance | 350 ± 3 Ω |
| Output Resistance | 350 ± 3 Ω |
| Voltage Supply | < 12 V (standard); 11…30 VDC (with optional amplifier) |
| Nominal Temperature Range | −10 … +40 °C |
| Service Temperature Range | −35 … +65 °C |
| Temperature Effect – Zero | < 0.015 % Fnom / 10 K |
| Temperature Effect – Span | < 0.011 % Fnom / 10 K |
| Nominal Deflection | < 0.4 mm |
| Electrical Connector | Cable outlet (PUR): 500 kg → 3 m; > 500 kg → 6 m |
| Protection Type (DIN 60529) | IP 68 |
| Deformation Body Material | Stainless Steel |
| Weight | 0.5 – 4 t: approx. 1.9 kg; 5 – 7.5 t: approx. 3.1 kg |