WIKA / Single point load cell, Model F4818

Applications
  • Precision scales
  • Industrial scales, test devices
  • Belt weighers
  • Bench scales
  • Dosing systems
Special features
  • Measuring ranges 0 … 20 kg to 0 … 500 kg [0 … 44 lbs to 0 … 1,102 lbs]
  • Load cell made from aluminium
  • High accuracy and quick reponse
  • Insensitive to lateral and corner load
  • Simple design, easy installation
Category:
Brand:

Description

Single point load cell, Model F4818

The model F4818 single point load cells are a series of aluminium single point load cells suitable for a wide range of applications. Thanks to their standardised geometry and simple design, they can be easily installed in all types of scales.

The model F4818 load cells are used in various are as such as industry, commerce, medicine and research.

The most common application area is in precision, industry and bench scales as well as belt weighers, to measure the weight of products (e.g., food, bulk material, feed). Load cells are also used in the packaging industry, manufacturing as well as material testing.

The single point load cells feature high accuracy and a quick reponse. Moreover, they are insensitive to lateral and corner loads.

The load cells are easy to handle due to their simple force introduction. This is made perpendicular to the geometry.

Specifications per VDI/VDE/DKD 2638

Parameter Value
Rated load (Fnom) 20 / 30 / 50 / 60 / 100 / 150 / 200 / 250 / 300 / 350 / 500 kg
Rated load (Fnom) 44 / 66 / 110 / 132 / 221 / 331 / 441 / 551 / 661 / 772 / 1,102 lbs
Relative linearity error (dlin) ±0.02 % Fnom
Relative creep, 30 min ±0.02 % Fnom
Relative reversibility error (v) ±0.02 % Fnom
Relative deviation of zero signal (dS₀) ±2 % Fnom
Temperature effect on zero signal (TK₀) ≤ ±0.025 % / 10 K
Temperature effect on characteristic value (TKC) ≤ ±0.025 % / 10 K
Force limit (FL) 120 % Fnom
Breaking force (FB) 200 % Fnom
Material of measuring body Aluminium
Rated temperature range (BT, nom) -10 … +40 °C [+14 … +104 °F]
Operating temperature range (BT, G) -20 … +60 °C [-4 … +140 °F]
Input resistance (Re) 410 ±10 Ω
Output resistance (Ra) 350 ±5 Ω
Insulation resistance (Ris) ≥ 2,000 MΩ / DC 100 V
Output signal (Cnom) 2.0 ±0.2 mV/V
Electrical connection Measuring cable ∅ 5 × 1,500 mm [∅ 0.19 × 59.06 in]
Supply voltage (UB, nom) DC 10 V (max. 15 V)
Ingress protection IP65
Platform size 450 × 450 mm [17.72 × 17.72 in]
Weight 0.6 kg [1.3 lbs]

1) Relative linearity error is specified in accordance with guideline VDI/VDE/DKD 2638 chapter 3.2.6.

Reviews