WIKA / Model F1811 Compression force transducer

Applications
  • Measuring and control systems
  • Production lines
  • Presses
  • Platform scales for trucks
Special features
  • Measuring ranges 0 … 2.5 kN to 0… 300 kN
  • Relative linearity error 0.1 % Fnom
  • Stainless steel version, completely welded
  • Low installation height, easy to install
  • Ingress protection IP67
Category:
Brand:

Description

Model F1811 Compression force transducer

Standard version up to 300 kN

Due to its compact design, the model F1811 force transducer is used very often in industrial applications such as production lines and control units. The spherical calotte (spherical load application button) allows for a very simple force introduction.

Compression force transducers are used for the determination of compression forces in a wide variety of applications and are suitable for static and dynamic measuring requirements.

Specifications per VDI/VDE/DKD 2638

Model F1811
Rated force Fnom kN 2.5 5 10 20 30 50 100 200 300
Rated force Fnom lbf 552 1,124 2,250 4,500 6,744 11,240 22,500 45,000 67,443
Relative linearity error dlin 0.1 % Fnom
Relative creep, 30 min. at Fnom 0.1 % Fnom
Relative reversibility error v 0.1 % Fnom
Relative span in unchanged mounting situation brg 0.1 % Fnom
Relative deviation of zero signal dS, 0 ±2 % Fnom
Temperature effect on the zero signal TK0 0.05 % Fnom/10 K
Temperature effect on the characteristic value TKC 0.05 % Fnom/10 K
Limit force FL 150 % Fnom
Breaking force FB 200 % Fnom
Material of the measuring body Stainless steel
Rated temperature range BT, nom -10 … +60 °C [-50 … +140 °F]
Service temperature range BT, G -20 … +80 °C [-68 … +176 °F]
Input resistance Re 750 ±10 Ω
Output resistance Ra 700 ±5 Ω
Insulation resistance Ris ≥ 5,000 MΩ/DC 100 V
Output signal (rated characteristic value) Cnom 1.5 ±0.15 mV/V
Electrical connection Cable Ø 5 × 5,000 mm [Ø 0.197 in × 197 in]
Voltage supply DC 10 V (max. 15 V)
Ingress protection (per IEC/EN 60529) IP66
Weight
2.5 kN … 100 kN 1.2 kg [2.65 lbs]
200 kN 1.6 kg [3.53 lbs]
300 kN 3.2 kg [7.05 lbs]

Dimensions in mm [in]

Rated force in kN [lbf] Dimensions in mm [in]
ØA B C ØD SR E F G ØK H L M
2.5 [552] / 5 [1,124] / 10 [2,250] / 20 [4,500] / 30 [6,744] / 50 [11,240] / 100 [22,500] 82 [3.23] 44 [1.73] 32 [1.26] 22 [0.87] 50 [1.97] 14 [0.55] 13 [0.51] 68 [2.67] M8 5,000 [197] 15.7 [0.62]
200 [45,000] 100 [3.94] 48 [1.89] 36 [1.41] 28 [1.10] 100 [3.94] 14 [0.55] 13 [0.51] 80 [3.15] M8 5,000 [197] 15.7 [0.62]
300 [67,443] 126 [4.96] 54 [2.12] 40 [1.57] 35 [1.38] 100 [3.94] 14 [0.55] 13 [0.51] 101 [3.98] M10 5,000 [197] 15.7 [0.62]

Pin assignment

Electrical connection
Excitation voltage (+) Red
Excitation voltage (-) Black
Signal (+) Green
Signal (-) White
Shield Shield