WIKA / Model F6154 Hydraulic ring force transducer

Applications
  • Equipment manufacturing
  • Geotechnology and specialist foundation engineering
  • Construction of jigs and fixtures
  • Special machine building
  • Measuring and control systems
Special features
  • Measuring ranges 0 … 25 kN to 0 … 1,500 kN [5,620 lbf to 337,213 lbf]
  • Relative linearity error:
    • ±1.0 … 1.6 % Fnom with analogue pressure gauge
    • ±0.5 % Fnom with digital pressure gauge or pressure sensor
  • Piston stroke ≤ 0.8 mm [≤ 0.03 in]
  • Operates without supply voltage
  • 5-year leak-tightness warranty
Category:
Tags: , ,
Brand:

Description

Model F6154 Hydraulic ring force transducer

Heavy-duty version up to 1,500 kN

The model F6154 hydraulic ring force transducer in heavy-duty design enables the measurement and display of forces in harsh environmental conditions. Its measuring ranges from 25 kN to 1,500 kN [5,620 lbf to 337,213 lbf]. Applications for hydraulic force measurement can be found in equipment manufacturing, in geotechnology and specialist foundation engineering, in device and special machine building and also with measurement and control systems.

The connection of the display instrument can, optionally, be made using a capillary or measuring hose. This enables the convenient reading of the measured value. Furthermore, the measuring hose offers the possibility of “separation without any losses”, which enables an exchange of the display instrument without the need for dismounting the force measuring unit.

Hydraulic force measurement makes use of a piston-case combination with different seals as a sensor unit. The force acting is the product of the area and the pressure. For the display of the pressure, either pressure gauges, pressure sensors or pressure measuring instruments with contact devices can be used. The scale of the display instrument can be defined in various units, e.g., in N, kN, kg, t.

Leak-tightness warranty
The warranty on leak tightness of the hydraulic force measuring unit was extended to 5 years. The prerequisite for this is of course the intended use of the force measuring unit. A force transducer that starts to leak within this period will be repaired free of charge. In this way, we are underlining the quality of our hydraulic force transducers and our confidence in our own technology.

Specifications per VDI/VDE/DKD 2638

Model F6154
Rated force Fnom 0 … 25 kN to 0 … 1,500 kN [0 … 5,620 lbf to 0 … 337,213 lbf]
Nominal size NS 240
Display 
■ Pressure gauge, model 213.40 (NS 63)
■ Pressure gauge, model PGS23
■ Digital pressure gauge, model DG-10
■ Pressure sensor (on request)
Relative linearity error dlin
Pressure gauge ≤ ±1.6 % Fnom
Pressure sensor/digital pressure gauge ≤ ±0.5 % Fnom
Force limit FL 100 % Fnom
Breaking force FB > 130 % Fnom
Rated displacement snom < 0.8 mm [< 0.03 in]
Rated temperature range BT, nom -25 … +90 °C [-13 … 194 °F]
Ingress protection (per IEC/EN 60529)
Pressure gauge IP65
Pressure sensor IP67
Digital pressure gauge IP65
Case Stainless steel
Piston Stainless steel
Diaphragm Plastic
Mounting type 
■ Direct mounting about adapter
■ Capillary
■ Measuring hose for “separation without any loss less connection“
Fill fluid Glycerine 70 % / water 30 %
Assembly aid Threaded holes on the bottom of the case
Weight 20.5 kg [45.19 lbs]

Dimensions in mm [in]

Dimensions in mm [in]
ØA ØB ØC ØD ØE F G H I J K L ØM
225 142 125 200 250 75 5 22.5 20 12.5 34 approx. 320 63
[8.86] [5.6] [4.9] [7.87] [9.84] [2.95] [0.2] [0.89] [0.79] [0.49] [1.34] [12.6] [2.48]
Version Pressure gauge Digital pressure gauge Options
Rated force System pressure Model 213.40 Model DG-10 Measuring hose DN 2 (max. L) Capillary (max. L)
kN bar m m
25 [5,620] 10 1.0 2.0
40 [8,992] 16 1.0 2.0
50 [11,240] 20 ■ 1) 1.5 2.0
60 [13,488] 25 1.5 2.0
100 [22,481] 40 1.5 2.0
120 [26,977] 50 2.0 2.0
150 [33,721] 60 2.0 2.0
250 [56,202] 100 2.0 2.0
400 [89,924] 160 2.0 Other lengths on request
600 [134,885] 250 3.2
1,000 [224,809] 400 3.2
1,500 [359,694] 600 3.2
Other rated loads and versions on request

2) Relative linearity error <±1.0 % Fnom
■ = possible selection / – = not available

Reviews

There are no reviews yet.

Be the first to review “WIKA / Model F6154 Hydraulic ring force transducer”