Description
T3B1 Series Tension Measurement for Industrial Weighing Systems
Features
- General purpose tension load cell
- Ideal for coversion of mechanical scales into electronic scales
|
Rated capacity
|
196.1 N {20 kgf} ~ 49.03 kN {5 tf}
|
|
Safe overload
|
150% R.C.
|
|
Ultimate overload
|
200% R.C.
|
|
Rated output
|
3 mV/V±0.015 mV/V
|
|
Non-linearity
|
0.03% R.O.
|
|
Hysteresis
|
0.03% R.O.
|
|
Repeatability
|
0.03% R.O.
|
|
Excitation, recommended
|
10 V or less
|
|
Excitation, maximum
|
15 V
|
|
Zero balance
|
±0.03 mV/V
|
|
Input resistance
|
350 Ω±3.5 Ω
|
|
Output resistance
|
350 Ω±5 Ω
|
|
Insulation resistance
|
2,000 MΩ or more (DC50 V) (between bridge and main body)
|
|
Temp. range, compensated
|
-10℃ ~ 70℃
|
|
Temp. range, safe
|
-20℃ ~ 80℃
|
|
Temp. effect on zero
|
0.05% R.O./10℃
|
|
Temp. effect on output
|
0.1% LOAD/10℃
|
|
Cable
|
φ6.3, 4 -cores 3 m cable directly attached. Y-crimp type terminal lugs are attached at cable end.
|
|
Class of protection
|
IP64 or equivalent
|
|
Material of element
|
T3B1-20K~200K: Alluminium alloy
T3B1-500K~5T: Alloy steel |
|
Paint
|
Main body: Painted with epoxy resin (Black)
Cover: Painted with polyurethane (Blue) |
|
Durability
|
1,000,000 times with rated load applied.
|
|
Parts No.
|
Rated capacity
|
Natural frequency
|
Rated displacement
|
Weight
(Approx.) |
|---|---|---|---|---|
|
T3B1-20K
|
196.1 N {20 kgf}
|
600 Hz
|
0.18 mm
|
0.33 kg
|
|
T3B1-50K
|
490.3 N {50 kgf}
|
1,100 Hz
|
0.16 mm
|
0.33 kg
|
|
T3B1-100K
|
980.7 N {100 kgf}
|
1,600 Hz
|
0.14 mm
|
0.33 kg
|
|
T3B1-200K
|
1.961 kN {200 kgf}
|
2,100 Hz
|
0.12 mm
|
0.33 kg
|
|
T3B1-500K
|
4.903 kN {500 kgf}
|
2,600 Hz
|
0.14 mm
|
0.63 kg
|
|
T3B1-1T
|
9.807 kN {1 tf}
|
3,000 Hz
|
0.12 mm
|
0.63 kg
|
|
T3B1-2T
|
19.61 kN {2 tf}
|
2,380 Hz
|
0.16 mm
|
1.7 kg
|
|
T3B1-5T
|
49.03 kN {5 tf}
|
2,272 Hz
|
0.20 mm
|
4 kg
|


Reviews
There are no reviews yet.