Description
FSU Series Force Sensor
Features
- Aluminum single point load cell
- Full bridge type
|
Rated capacity
|
4.903 N{0.5 kgf}~147.1 N{15 kgf}
|
|
Safe overload
|
450% R.C.
|
|
Ultimate overload
|
600% R.C.
|
|
Rated output
|
0.5 mV/V±0.05 mV/V (FSU-0.5K : 0.5 mV/V±0.075 mV/V)
|
|
Non-linearity
|
0.1% R.O.
|
|
Hysteresis
|
0.1% R.O.
|
|
Repeatability
|
0.1% R.O.
|
|
Creep
|
0.15% R.O./20 min
|
|
Creep recovery
|
0.15% R.O./20 min
|
|
Excitation, recommended
|
5 V or less
|
|
Excitation, maximum
|
8 V
|
|
Zero balance
|
±0.4 mV/V
|
|
Input resistance
|
340 Ω±50 Ω
|
|
Output resistance
|
340 Ω±50 Ω
|
|
Insulation resistance
|
1,000 MΩ or more (DC50 V) (between bridge and main body)
|
|
Temp. range, compensated
|
0℃ ~ 60℃
|
|
Temp. range, safe
|
-10℃ ~ 80℃
|
|
Temp. effect on zero
|
±1% R.O./10℃
|
|
Temp. effect on output
|
±1% LOAD/10℃
|
|
Lead wire
|
AWG30, 150 mm directly attached, cable end is separated
|
|
Class of protection
|
IP00 or equivalent
|
|
Material of element
|
Alluminium alloy
|
|
Weight
|
Approx. 30 g
|
|
Durability
|
1,000,000 times with rated load applied.
|
|
Effect of eccentric load
|
– The center of loading plate and also the center of load cell should be the same position.
– Error is within 0.8% R.O. applied with 1/2 of rated capacity at the position of 50 mm of eccentricity. |
|
Parts No.
|
Rated capacity
|
|---|---|
|
FSU-0.5K
|
4.903 N {0.5 kgf}
|
|
FSU-1K
|
9.807 N {1 kgf}
|
|
FSU-2K
|
19.61 N {2 kgf}
|
|
FSU-5K
|
49.03 N {5 kgf}
|
|
FSU-15K
|
147.1 N {15 kgf}
|