Description
FC23 Compression Load Cell
The FC23 is a high compression force sensor thatcreates new markets previously unrealizable due to costand performance constraints. The FC23 offers normalizedzero and span for interchangeability and is thermallycompensated for changes in zero and span with respect totemperature.The FC23 incorporates MEAS’ proprietaryMicrofused™ technology which employs micromachinedsilicon piezoresistive strain gages fused with hightemperature glass to a high performance stainless steelsubstrate. Microfused™ technology eliminates agesensitiveorganic epoxies used in traditional load celldesigns providing excellent long-term span and zerostability. The FC23 measures direct force and is thereforenot subject to lead-die fatigue failure common withcompetitive designs which use a pressure capsuleembedded within a silicone gel-filled cavity. Operating atvery low strains, Microfused™ technology provides anessentially unlimited cycle life expectancy, superiorresolution, and high over-range capabilities.The FC23 brings your OEM product to life whetheryou need thousands or millions of load cells annually.Although the standard model is ideal for a wide range ofapplications, our dedicated design team at our Load CellEngineering Center is ready to provide you with customdesigns for your OEM applications.Please refer to models FS20 and FC22 for lower forceapplications.
FEATURES
– Interchangeable
– Low Noise
– Robust: High Over-Range Capability
– High Reliability
– Low Deflection
– Low Off Center Errors
– Fast Response Time
– Long Cycle Life Expectancy
APPLICATIONS
– Batch Weighing
– Robotics End-Effectors
– Variable Force Control
– Load and Compression Sensing
– Assembly Line Force Measurement
– Pumps
– Hoist and Winch Loads
– Weighing
STANDARD RANGES
| Range (lbf) | |
|---|---|
| 0 to 0050 lbf | ● |
| 0 to 0100 lbf | ● |
| 0 to 0250 lbf | ● |
| 0 to 0500 lbf | ● |
| 0 to 1000 lbf | ● |
| 0 to 2000 lbf | ● |
PERFORMANCE SPECIFICATIONS
Unless otherwise specified: Supply Voltage: 5.0V, Ambient Temperature: 25°C
| Parameters | Min | Typ | Max | Units | Notes |
|---|---|---|---|---|---|
| Span (mV) | 95 | 100 | 105 | mV | 1 |
| Span (Amplified) | 3.8 | 4.0 | 4.2 | V | 1 |
| Zero Force Output (mV) | -20 | 0 | 20 | mV | 1 |
| Zero Force Output (Amplified) | 0.3 | 0.5 | 0.7 | V | 1 |
| Accuracy (non-linearity, hysteresis, repeatability) | -1 | 1 | %Span | 2 | |
| Input Resistance (mV) | 3.0 | kΩ | |||
| Output Resistance (mV) | 2.2 | kΩ | |||
| Temperature Error – Span (Amplified & mV) | -2.5 | 2.5 | %Span | 3 | |
| Temperature Error – Zero (Amplified & mV) | -2.5 | 2.5 | %Span | 3 | |
| Supply Voltage (mV) | 2 | 5 | 10 | V | 1 |
| Supply Voltage (Amplified) | 4.5 | 5 | 5.5 | V | 1 |
| Response Time (10% to 90%) | 1.0 | ms | |||
| Long Term Stability (1 year) | ±1 | %Span | |||
| Maximum Overload | 2.5× Rated | ||||
| Compensated Temperature | 0 | 50 | °C | ||
| Operating Temperature | -40 | +85 | °C | ||
| Storage Temperature | -40 | +85 | °C | ||
| Isolation Resistance (250 Vdc) | 50 | MΩ | |||
| Deflection at Rated Load | 0.05 | mm | |||
| Humidity | 0 | 90 | %RH |
For custom configurations, consult factory.
Notes
1. Ratiometric to supply.
2. Best fit straight line.
3. Maximum temperature error over compensated range with respect to 25°C.
CE Compliance
IEC61000-4-2: [4kV/ 4 kV (Air/Contact)]
IEC61000-4-3: (3 V/m)
DIMENSIONS

CONNECTIONS

ORDERING INFORMATION