Beam Load Cell BL (BL-Ex)
Special Features
|
|
Dimensions (mm)

Specifications
| Parameter | Unit | 0.025%* | ||
| Rated capacity (Emax) | kg | 1, 2, 5, 10, 20, 30, 50 | ||
| Safe overload limit | % of Emax | 200 to 500 | ||
| Safe sideload limit | % of Emax | 300 to 500 | ||
| Combined accuracy | % of Emax | 0.025 | ||
| Repeatability | % of Emax | 0.010 | ||
| Hysteresis | % of Emax | 0.017 | ||
| Creep 30 min. | % of Emax | 0.017 | ||
| Temperature effect on zero | % of Emax | 0.035 | ||
| Temperature effect on sensitivity | % /10°C | 0.035 | ||
| Compensated temperature range | % /10°C | -10 to 50 | ||
| Operating temperature range | °C | -50 to 60 | ||
| Deflection at Emax | °C | max 0.10 | ||
| Measuring rate | mm | 500 | ||
| Supply | Hz | 24Vdc ±5% | ||
| Internal resolution | Vdc | 24 | ||
| Material | Bit | Stainless Steel 17-4 PH and AISI 316 | ||
| Protection | IP68 | |||
| Cable | 6 meter standard coaxial RG-58 (Ø6mm) with BNC connector | |||
| Maximum Cable Length | 100 | |||
| Weight | kg | 1.5 | ||
| Output Options | EtherNet/IP, PROFINET, EtherCAT, Profibus DP, Modbus TCP/IP, DeviceNet, RS485/422, 4-20mA, 0-10Vdc |
|||
* Higher accuracies on request
Applications
- Web tension measurement
- Force measurement
- Dynamic weighing
- Process weighing
- Small tanks and vessels
- Vibration sorters
- Filling and dosing
Options
- Load cell cable length 10, 20, 50 or 100 meters
- Special PE load cell cable available for freezing low temperature (can be used down to -50 degrees Celsius)
- Special Teflon load cell cable available for very high temperature (can be used up to 100 degrees Celsius)