Description
Model 1130 Stainless Steel Single-Point Load Cell
FEATURES
• Capacities 7–100 kg
• Stainless steel construction
• Single-point 400 × 400 mm platform
• OIML R60 and NTEP approved
• IP66 protection
• Available with metric and UNC threads
• Optional
❍ ATEX, FM and IECEx approvals available
APPLICATIONS
• Harsh environment small platforms
• Harsh environment check weighing

| SPECIFICATIONS | ||||
| PARAMETER | VALUE | UNIT | ||
| Rated capacity—R.C. (Emax) | 7, 10, 15, 20, 30, 50, 75, 100 | kg | ||
| NTEP/OIML accuracy class | NTEP(1) | Non-Approved | C3(2) | |
| Maximum no. of intervals (n) | 4000 single | 1000 | 3000(3) | |
| Y = Emax/Vmin | 15000 | 2000 | 15000 | |
| Rated output—R.O. | 2.0 | mV/V | ||
| Rated output tolerance | 0.2 | ±mV/V | ||
| Zero balance | 0.2 | ±mV/V | ||
| Zero return, 30 min. | 0.0250 | 0.0300 | 0.0170 | ±% of applied load |
| Total error (per OIML R60) | 0.0015 | 0.0500 | 0.0200 | ±% of rated output |
| Temperature effect on zero | 0.0030 | 0.0100 | 0.0023 | ±% of rated output/°C |
| Temperature effect on output | 0.0008 | 0.0030 | 0.0010 | ±% of applied load/°C |
| Eccentric loading error | 0.0035 | 0.0074 | 0.0049 | ±% of rated load/cm |
| Temp. range, compensated | –10 to +40 | °C | ||
| Temp. range, safe | –20 to +70 | °C | ||
| Maximum safe central overload | 150 | % of R.C. | ||
| Ultimate central overload | 300 | % of R.C. | ||
| Excitation, recommended | 10 | VDC or VAC RMS | ||
| Excitation, maximum | 15 | VDC or VAC RMS | ||
| Input impedance | 385±15 | Ω | ||
| Output impedance | 350±3 | Ω | ||
| Insulation resistance | >2000 | MΩ | ||
| Cable length | 1.5 | m | ||
| Cable type | 6-wire, PVC, single loating screen | Standard | ||
| Construction | Stainless steel | |||
| Environmental protection | IP66 | |||
| Platform size (max.) | 400 × 400 | mm | ||
| Recommended torque | 13.0 | N*m | ||