Revere Transducers / Model BSP Universal Load Cell

The load cell model BSP is a stainless steel S – type load cell designed for tension and compression. The load cell is well suited for hybrid scales, overhead track scales, belt scales and process weighing applications. The fully welded constructions and water block cable entry ensure that the BSP is suitable in a harsh environment found in the food, chemical and allied process industries. For hazardous environments it is available in an ATEX or FM approved version. Certified to OIML R-60, 3000d. Hermetically sealed, IP66 and IP68. The load cell is available in the capacities 50 -5000 kg and 100 -10 k lbs.

Brand: , ,

Description

Model BSP Universal Load Cell

FEATURES
• Capacities: 50–5000 kg, 100–10k lbs
• Fully welded, stainless steel construction
• Hermetically sealed, IP66 and IP68
• Certiied to OIML R-60, 3000d
• Integrated overload stop (50–500 kg)
• Current calibration output (SC version) ensures easy
and accurate parallel connection of multiple load cells
• Optional
❍ ATEX and FM certiied versions are available

APPLICATIONS
• Hybrid scales
• Process weighing
• Belt checkweighers
• Dynamometers
• Material testing machines

SPECIFICATIONS
PARAMETER VALUE UNIT
Standard capacities (Emax) 50, 125, 250, 500, 1250, 2500, 5000 kg
Standard capacities (Emax) 100, 250, 500, 1000, 2500, 5000, 10000 lbs
Accuracy class according to OIML R-60 /NTEP NTEP IIIL Non-Approved C3  
Maximum number of verfication intervals 10000   3000  
Minimum verification interval = Vmin/Emax/Y)   Emax/10000  
Rated output (=S) 3 (2 for 2500 and 5000 kg) mV/V
Rated output tolerance 0.03 (0.02 for 2500 and 5000 kg) ± mV/V
Zero balance 1.0 ±% FSO
Combined error 0.0200 0.0500 0.0200 ±% FSO
Non-repeatability 0.0100 0.0200 0.0100 ±% FSO
Minimum dead load output return   0.0500 0.0167 ±% FSO
Creep error (30 minutes)   0.0600 0.0245 ±% FSO
Creep error (20–30 minutes) 0.0300 0.0200   ±% FSO
Temp. effect on minimum dead load output (0.0008) 0.0250 0.0070 ±% FSO/5°C (/°F)
Temperature effect on sensitivity (0.0010) 0.0250 0.0050 ±% FSO/5°C (/°F)
Minimum dead load 0 % Emax
Maximum safe overload 150 % Emax
Ultimate overload 300 % Emax
Maximum safe side load 100 % Emax
Deflection at Emax 0.28 max. mm
Excitation voltage 5 to 15 V
Maximum excitation voltage 18 V
Input resistance 350±3.5 Ω
Output resistance 350±3.5 Ω
Insulation resistance ≥5000
Compensated temperature range –10 to +40 °C
Operating temperature range –40 to +80 °C
Storage temperature range –40 to +90 °C
Element material (DIN) Stainless steel 1.4542  
Sealing (DIN 40.050 / EN60.529) IP66 and IP68  
SC-Version (current calibration) Standard  

FSO—Full Scale Output
SC-version: The rated output and the output resistance are balanced in such a way that the output current is calibrated to within 0.05%
of a reference value. This allows easy parallel connection of the load cells.
All speciications subject to change without notice.