Sensortronics / 65114 Double-Ended Shear Beam Load Cell

Model 65114 is a high capacity, stainless steel singlecolumncompression load cell.This product is specifically designed for use in ruggedoutdoor environments. Made from stainless steel, IP67welded sealing comes standard, with optional, fullyhermetic, IP68 sealing available upon request. This loadcell is used primarily in truck and train scales, but can justas easily be used to weigh tanks and silos.The load cell is rated intrinsically safe by the FactoryMutual System (FM); making it suitable for use inpotentially explosive environments. The load cell iscertified for Legal-for-Trade applications by bothAmerican NTEP and International OIML standards.

Brand: ,

Description

65114 Stainless Steel, Single-Column Compression Load Cell

FEATURES
• Rated capacities of 50,000 to 100,000 pounds;
25 to 50 metric tonnes
• Stainless steel, welded seal construction
• 30 feet standard cable length
• Trade certified for NTEP Class IIIL: 10000 divisions and
OIML R60 3000 divisions
• Welded Sensorgage™ sealed to IP67 standards
• Factory Mutual System Approved for Classes I, II, III;
Divisions 1 and 2; Groups A through G.
• Non-incendive ratings (without barriers)
• Optional
– Hermetically sealed version, meets IP66/68 standards

APPLICATIONS
• Truck scales
• Tank, bin, and hopper weighing

SPECIFICATIONS
PARAMETER VALUE UNIT
Rated capacity—R.C. (Emax) 50k, 100k 25, 35, 50 lbs t
NTEP/OIML accuracy class NTEP IIIL Standard OIML R60  
Maximum no. of intervals (n) 10000 multiple   3000  
Y = Emax/Vmin NTEP cert. 97-081   8333 Maximum available
Rated output—R.O. 2.0 mV/V
Rated output tolerance 0.25 ±% mV/V
Zero balance 1.0 ±% FSO
Combined error 0.02 0.03 0.02 ±% FSO
Non-repeatability 0.010 0.015 0.010 ±% FSO
Creep error (30 minutes) 0.03 0.05 0.017 ±% FSO
Temperature effect on zero 0.0010 0.0015 0.0010 ±% FSO/°F
Temperature effect on output 0.0008 0.0008 0.0007 ±% of load/°F
Compensated temperature range 14 to 104 (–10 to 40) °F (°C)
Operating temperature range 0 to 150 (–18 to 65) °F (°C)
Storage temperature range –60 to 185 (–50 to 85) °F (°C)
Maximum safe central overload 150 % of R.C.
Ultimate central overload 300 % of R.C.
Excitation, recommended 5–20 VDC or VAC RMS
Excitation, maximum 25 VDC or VAC RMS
Input impedance 1000 nominal Ω
Output impedance 990–1010 Ω
Insulation resistance at 50 VDC >1000
Material Stainless steel  
Environmental protection IP67*  

* Hermetically sealed to IP68 upon request
FSO—Full Scale Output
All specifications subject to change without notice.