Applied Measurement CS131 Series Load Cell

CS131 Series Load Cell CS131 uses Crane and Overload applications Electroless nickel plated for corrosion resistance. Specifications Accuracy Rated capacity (R.O) 8tf, 10tf, 25tf Rated output (R.O) 2mv/v±0.3% Non-linearity 0.5% R.O. Hysteresis 0.5% R.O. Repeatability 0.5% R.O. Zero balance 1±1% R.O. Temp. Range Compensated -10~40℃ Temp. Effect on Rated Output

Brand:

Description

CS131 Series Load Cell

  • CS131 uses Crane and Overload applications
  • Electroless nickel plated for corrosion resistance.
Specifications Accuracy
Rated capacity (R.O) 8tf, 10tf, 25tf
Rated output (R.O) 2mv/v±0.3%
Non-linearity 0.5% R.O.
Hysteresis 0.5% R.O.
Repeatability 0.5% R.O.
Zero balance 1±1% R.O.
Temp. Range Compensated -10~40℃
Temp. Effect on Rated Output ±0.05% Load/10℃
Temp. Effect on Zero Balance ±0.05% R.O./10℃
Resistance, Input 700Ω±3.5Ω
Resistnace, output 700Ω±5Ω
Insulation Resistance Bridge To Ground 2000㏁
Electrical Connection φ7mm×4C×10m
Exc. Recommended 10V
Safe Overload 150% R.C.