Description
Single Point Load Cell LA360-S
- CE-verifiable capacities: 10, 20, 50, 75, 100, 200 kg
- version anodised aluminium
- protection class IP 66
- accuracy class C3
- for weighing platforms up to and included 400 x 400 mm
- can be used as a replacement for type 1042
- see further the leaflet
TECHNICAL DATA
Construction Anodised Aluminum Alloy
| PARAMETER | UNIT | VALUE | ||||||||||||||
| OIML Accuracy | C3 | |||||||||||||||
| Rated capacity (Emax) | kg | 10, 20, 50, 75, 100, 200 | ||||||||||||||
| Sensitivity | mV/V | 2.00 | ||||||||||||||
| Sensitivity tolerance | ± mV/V | 0.20 | ||||||||||||||
| Zero balance | ± mV/V | 0.10 | ||||||||||||||
| Maximum Number of Intervals | 3000 | |||||||||||||||
| Y=Emax/vmin | Minimum | 6000 | ||||||||||||||
| Z=Emax/(2*DR) | Minimum | 3000 | ||||||||||||||
| Eccentric loading error | ±%/cm | 0.0042 | ||||||||||||||
| Maximum platform size | cm | 40×40 | ||||||||||||||
| Nominal temperature range | °C | -10 to +40 | ||||||||||||||
| Service temperature range | °C | -30 to +70 | ||||||||||||||
| Limit load | % of R.C. | 150 | ||||||||||||||
| Break load | % of R.C. | 300 | ||||||||||||||
| Nominal excitation | V | 10 | ||||||||||||||
| Max. excitation | V | 15 | ||||||||||||||
| Input impedance | Ohm | 406 ± 15 | ||||||||||||||
| Output impedance | Ohm | 350 ± 3 | ||||||||||||||
| Insulation resistance | MOhm | >2000 | ||||||||||||||
| Compensation circuit type | Balanced Bridge | |||||||||||||||
| Cable length | Meter | 3.0 | ||||||||||||||
| Cable type | 6×26 AWG, Black PVC Jacket | |||||||||||||||
| Color code |
|
|||||||||||||||
| Protection class to IEC529 | IP 66 |
LA360-S-single-point-load-cell_eng


Reviews
There are no reviews yet.