Description
Force transducers for the measurement of static and dynamic loads in COMPRESSION and TENSION.
Nominal Load from 30 kN to 1000 kN
Class (ISO 376) 00, 0.5 and 1
Linearity and Hysteresis 0,03%
Output: 2mV/V

Dimensions[mm]

| CODE (Class 00) | CODE (Class 0.5) | CODE (Class 1) | LOAD | A | B | C | D | ÆE | ÆF | ÆG | H |
|---|---|---|---|---|---|---|---|---|---|---|---|
| CLB30KNI00 | CLB30KNI0 | CLB30KNI1 | 30 kN | M20x1.5 | 19 | 23 | 120 | 79 | 42 | 60 | 60 |
| CLB50KNI00 | CLB50KNI0 | CLB50KNI1 | 50 kN | M30x2 | 21 | 25 | 120 | 79 | 42 | 60 | 60 |
| CLB100KNI00 | CLB100KNI0 | CLB100KNI1 | 100 kN | ||||||||
| CLB200KNI00 | CLB200KNI0 | CLB200KNI1 | 200 kN | M42x3 | 30 | 32 | 150 | 102 | 60 | 70 | 72 |
| CLB300KNI00 | CLB300KNI0 | CLB300KNI1 | 300 kN | ||||||||
| CLB500KNI00 | CLB500KNI0 | CLB500KNI1 | 500 kN | M42x3 | 32 | 37 | 210 | 102 | 60 | 80 | 72 |
| CLB600KNI00 | CLB600KNI0 | CLB600KNI1 | 600 kN | M56x3 | 35 | 40.5 | 210 | 102 | 67 | 80 | 72 |
| CLB1MNI00 | CLB1MNI0 | CLB1MNI1 | 1 MN | M60x3 | 60 | 65 | 290 | 129 | 102 | 129 | 85 |
(1)ACCREDIA certification can NOT be performed by LAT 00120 Laboratory, on request it can be ordered to other Accredited Laboratories.
Technical Data
| Accuracy Class: ISO 376 | 00 | 0.5 | 1 | |||
|---|---|---|---|---|---|---|
| Nominal Load | 30, 50, 100, 200, 300, 500, 600, 1000 kN | |||||
| Relative Errors (at reading) a) Repeatability 0°-120°-240° (b) b) Interpolation (fc) c) Reversibility (u) d) Zero (fo) |
≤±0.050% (1) ≤±0.020% (1) ≤±0.070% (1) ≤±0.010% F.S. |
≤±0.085% (1) ≤±0.040% (1) ≤±0.135% (1) ≤±0.020% F.S. |
≤±0.150% (1) ≤±0.055% (1) ≤±0.250% (1) ≤±0.020% F.S. |
|||
| Linearity Hysteresis |
≤±0.03% F.S. ≤ ±0.03% F.S. |
|||||
| Temperature Effect (10°C) a) on zero b) on sensitivity |
≤±0.030% F.S. ≤±0.011% F.S. |
|||||
| Nominal Sensitivity Sensitivity Tolerance |
2 mV/V ≤±0.1% F.S. |
|||||
| Nominal Load Input resistance Output resistance |
30, 50, 100, 200 kN 350 ± 2Ω 350 ± 2Ω |
|||||
| Nominal Load Input resistance Output resistance |
300, 500, 600, 1000 kN 700 ± 2Ω 700 ± 2Ω |
|||||
| Insulation Resistance Zero Balance Recommended Supply Voltage Maximum Supply Voltage |
> 5 GW ≤±1% F.S. 10 V / 1-15 V 18 V |
|||||
| Mechanical Limit Values Referred to Nominal Load: a) Service load b) Max permissible load c) Breaking load d) Max transverse load e) Max permissible dynamic load Displacement at nominal load |
120% |
|||||
| Reference Temperature Temperature Nominal Range Service Temperature Storage Temperature |
+23°C -10 / +40 °C -10 / +70 °C -20 / +80 °C |
|||||
| Weight | 30–100 kN ~2.4 kg | 200, 300 kN ~4.6 kg | 500, 600 kN ~8.5 kg | 1 MN ~18.5 kg | ||
| Protection Class (EN 60529) Execution Material Connector Output |
IP67 Acciaio Inox / Stainless Steel M12 8 Poles Male connector |
|||||
| Recommended Knuckle Joints | DURBAL EM20 – EM30 – EM42 | |||||
(1) Percentual errors referred to reading, min. 1/ 10 of nominal load.
Classifications according ASTM E74 on request.

Shield connected to the body of the load cell.
Applications

| A | B | C | D | ØE | |
|---|---|---|---|---|---|
| CLB 30 kN | 157 | ~240 | — | — | — |
| CLB 50 kN | 159 | ~300 | — | — | — |
| CLB 100 kN | 159 | ~300 | — | — | — |
| CLB 200 kN | 210 | ~420 | ~530 | 354 | Ø100 |
| CLB 300 kN | 210 | ~500 | ~530 | 354 | Ø100 |
| CLB 500 kN | 260 | ~600 | ~640 | 421 | Ø126.5 |
| CLB 600 kN | 277 | — | ~640 | 421 | Ø126.5 |
| CLB 1000 kN | 378 | — | ~790 | 566 | Ø127 |