AEP transducers / TP3 / Pressure transducer

The pressure transmitters of this series are characterized by high reliability and long-term stability
High mechanical strength, suitable for dynamic applications
The sensitive part in contact with pressure, is entirely made of 17-4 PH stainless steel resistant to corrosion
Protection class IP65
Process coupling 1/4″ GAS Male
Connector standard DIN 43650
Internal adjustment of ZERO
Power supply 12 to 24 Vdc

Category:

Description

Pressure transmitters for RELATIVE, ABSOLUTE and VACUUM measures Nominal pressures from 100 mbar to 2000 bar AMPLIFIED outputs: 4-20mA, 10V or 5Volt Linearity and hysteresis 0,50%

 

Pressure transmitters belonging to TP3 series distinguish themselves for high long-term reliability of mechanical and electrical features and for their low price, obtained by minimising production costs with the use of new technologies, robotized stations and a diffuse use of LASER.
Among the sectors where these transmitters are employed, some are worth being underlined: pneumatic, hydraulic, refrigerating and level plants. They are also used in test benches and in materials testing machines.
The sensitive part, in contact with pressure, is entirely made of 17-4 PH corrosion-proof stainless steel.
High vacuum thermal treatments which stainless steel is subjected to, ensure the correct functioning even when highly dynamic stresses are involved. Monolithic execution of measuring element, without any assembling via tight rings or gaskets, guarantees a high long-term stability, with negligible hysteresis and zero drift. Pressure is internally detected by a full bridge strain gauge, which assures the maintenance of performances even in presence of peaks.
Electronic section, realised via SMD technology, consists of a high precision instrumental amplifier and a stable supplier, protected against short circuits and polarity inversion.
Every pressure transmitter is entirely LASER welded and completely resin-encapsulated, to ensure insensitivity and a high degree of hermetic tight.
During production cycle, pressure transmitters are thermally compensated, tested and individually calibrated with the use of completely automated stations that analyse and record data.

Dimensions

Technical Data

GAUGE PRESSURE (R)
Zero at atmospheric pressure
100 – 250 – 500 mbar
1 – 2.5 – 5 – 10 – 20 bar
ABSOLUTE PRESSURE (A)
Zero at pressure to absolute vacuum
1 – 2.5 – 5 – 10 – 20 bar
50 – 100 – 250 – 350 – 500 – 700 bar
*1000 – *1500 – *2000 bar
LINEARITY and HYSTERESIS ≤ ± 0.50 %
TEMPERATURE EFFECT (1°C)
a) on zero
b) on sensitivity
≤ ± 0.02%
≤ ± 0.02%
NOMINAL SENSITIVITY 4–20 mA (2 or 3 wires)
0–5 V, 0–10 V
CALIBRATION TOLERANCE ≤ ± 0.2%
NOMINAL POWER SUPPLY 4–20 mA and 0–5 V → 12–24 Vdc
0–10 V → 15–24 Vdc
MAX. POWER SUPPLY
MAX. ABSORPTION:

a) 3 wires
b) 2 wires
LOADING RESISTANCE:
a) tension
b) current
INSULATION RESISTANCE
ZERO BALANCE
RESPONSE FREQUENCY
28 Vdc

30 mA
20 mA

min. 3 kΩ
from 0 to 470 Ω
> 2 GΩ
± 10% ADJ.
from 0.5 to 5 kHz

LIMIT MECHANICAL VALUES REFERRED TO NOMINAL PRESSURE:
a) service pressure
b) max. permissible pressure
c) breaking pressure
d) highly dynamic pressure
100%
150%
> 300%
75%
REFERENCE TEMPERATURE
WORKING TEMPERATURE
STORAGE TEMPERATURE
+23°C
−10 / +70°C
−20 / +80°C
PROCESS COUPLING
TIGHTENING WRENCH
TIGHTENING TORQUE
1/4″ Gas (*1/2″ Gas) Maschio / BSP Male
27 mm
28 Nm
PROTECTION CLASS (EN 60529)
SENSOR EXECUTION MATERIAL
ELECTRICAL CONNECTION
IP65 — INOX 17-4 PH
DIN Connector 43650-A / ISO 4400

OPTIONS
ELECTRICAL CONNECTION: Female 4 poles straight M12x1
CONNECTOR complete PVC molded CABLE, shielded, length: 3m.
MOCA certification for food applications (pressure ≥ 20bar)

Electrical connections

(1) ZERO adjustment is accessible by unscrewing the nut.

 

 

 

Reviews

There are no reviews yet.

Be the first to review “AEP transducers / TP3 / Pressure transducer”