Description
TRS STATRIC torque transducer
For the measurement in clockwise and anticlockwise direction
SQUARE drive process coupling (UNI ISO 1174-1)
Nominal torque from 0.5 N•m to 1000 N•m
Linearity and Hysteresis: 0.2% or 0.1%
Output: 2 mV/V
LOW PRICE and EASY APPLICATIONS

Dimensions[mm]

| CODE | LOAD | A | B | C | D | E | F | G |
|---|---|---|---|---|---|---|---|---|
| (1) MTRS05NM | 0.5 N·m | 1/4” | 7.5 | 44 | 8 | 10 | 45 | 85 |
| (1) MTRS2.5NM | 2.5 N·m | 1/4” | 7.5 | 44 | 8 | 10 | 45 | 85 |
| MTRS5NM | 5 N·m | 1/4” | 7.5 | 44 | 8 | 10 | 45 | 85 |
| MTRS10NM | 10 N·m | 1/4” | 7.5 | 44 | 8 | 10 | 45 | 85 |
| MTRS25NM | 25 N·m | 3/8” | 10.5 | 44 | 11 | 10 | 45 | 85 |
| MTRS50NM | 50 N·m | 3/8” | 10.5 | 44 | 11 | 10 | 45 | 85 |
| MTRS100NM | 100 N·m | 1/2” | 15.0 | 44 | 16 | 10 | 45 | 85 |
| MTRS250NM | 250 N·m | 1/2” | 15.0 | 44 | 16 | 10 | 45 | 85 |
| MTRS500NM | 500 N·m | 3/4” | 22.5 | 53.5 | 24 | 17.5 | 51 | 91 |
| MTRS1KNM | 1000 N·m | 3/4” | 22.5 | 53.5 | 24 | 17.5 | 51 | 91 |
(1) ACCREDIA certification can NOT be performed by LAT n° 93 Laboratory, on request it can be ordered to other Accredited Laboratories.
Technical Data
| STATIC NOMINAL TORQUE | 0.5* – 2.5 N·m 5 – 10 – 25 – 50 – 100 N·m 250 – 500 – 1000 N·m |
| LINEARITY and HYSTERESIS | ± 0.20 % (see options) |
| TEMPERATURE EFFECT (1°C) a) on zero b) on sensitivity |
± 0.02 % ± 0.02 % |
| NOMINAL SENSITIVITY SENSITIVITY TOLERANCE |
2 mV/V (*0.5 N·m: 1 mV/V) ± 0.5 % |
| Input resistance Output resistance |
825 ± 50 Ω 700 ± 2 Ω |
| NOMINAL POWER SUPPLY MAX. POWER SUPPLY INSULATION RESISTANCE ZERO BALANCE |
1–15 V 18 V >2 GΩ ± 1 % |
| LIMIT MECHANICAL VALUES REFERRED TO NOMINAL TORQUE a) service torque b) max. permissible torque c) breaking torque d) highly dynamic torque |
100 % 150 % >300 % 70 % |
| REFERENCE TEMPERATURE WORKING TEMPERATURE RANGE STORAGE TEMPERATURE RANGE |
+23°C -10/+70°C -20/+80°C |
| PROTECTION CLASS (EN 60529) SENSOR EXECUTION MATERIAL ELECTRICAL CONNECTION |
IP40 INOX 17-4 PH Cable 5 m |
| PROCESS COUPLING (UNI ISO 1174-1) 0.5 – 2.5 – 5 – 10 N·m 25 – 50 N·m 100 – 250 N·m 500 – 1000 N·m |
1/4” 3/8” 1/2” 3/4” |
Options:
- LINEARITY and HYSTERESIS £ ± 10 %
| COPPIA NOMINALE | NOMINAL TORQUE | N·m / kN / N | 0.5 | 2.5 | 5 | 10 | 25 | 50 | 100 | 250 | 500 | 1000 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Carico assiale limite | Max axial permissible load | kN | 0.38 | 0.38 | 0.5 | 0.9 | 2.2 | 3.5 | 6 | 9.5 | 18 | 28 |
| Carico laterale limite | Max lateral permissible load | N | 15 | 15 | 15 | 30 | 30 | 80 | 150 | 180 | 250 | 400 |
| Mom. flettente limite | Bending limit moment | N·m | 1 | 1 | 1.5 | 3.5 | 4.5 | 15 | 20 | 42 | 65 | 170 |
For correct measurement both axial and transverse forces and bending moment should be absent. In case of presence, they must not be greater than values indicated below, to be reduced in simultaneous presence of more solicitations.
Electrical Connections
PVC 105°C shielded cable, Ø5.2mm with 4 tinned Ø0.35mm2 conductors. Shield connected to the body of the torque meter.

* Connected to the body of the torque transducer.