AM-104 Load Cell (Membrane box sensor)
Technical Specifications
| Accuracy Class | OIML R60 C3 | |
| Output Sensitivity ( = FS ) | mV/V | 2.0 ± 0.2 |
| Maximum Capacity ( Emax ) | kg | 20,50,100,200,300,500,1t,2t,3t,5t |
| Max. Number of Load Cell Intervals | nLC | 3000 |
| Ratio of min. LC Verification Interval | Y = Emax / vmin | 10000 |
| Combined Error | %FS | ≤± 0.0230 |
| Minimum dead load | Of Emax | 0% |
| Safe overload | of Emax | 150 % |
| Ultimate overload | of Emax | 300 % |
| Zero balance | of FS | < ± 2.0 % |
| Excitation, recommended voltage | V | 5 ~ 12 |
| Excitation maximum | V | 18 |
| Input resistance | Ω | 700 ± 15 |
| Output resistance | Ω | 700 ± 3.5 |
| Insulation resistance | MΩ | ≥5000 ( at 50VDC ) |
| Compensated temperature | °C | -10 ~+40 |
| Operating temperature | °C | -35 ~ +65 |
| Storage temperature | °C | -40 ~ +70 |
| Element material | stainless steel | |
| Ingress Protection (acc. to EN 60529) | IP67 | |
| Recommended torque on fixation bolts | Nm |