Description
KDH-5 Weigh Module
Features
- Easy installation
- No extra mounting detail is needed
- Movable load point
- Compact and robust
- Allow movement caused by thermal expansion
- FM, ATEX and IECEx certified for hazardous locations
Product Type: Weigh Modules & Load Cells
DIMENSIONS in millimeters – 20-500 kN capacity

| Range kN | A | B | C | D | E | F | G | H | I | J | K:0 | L : Thread/Depth |
| 20 – 200(1) | 107 | 48 | 14 | 80 | 50 | 200 | 160 | 130 | 170 | 30 | 14 | M12 / 20 |
| 200(2) – 500 | 156,5 | 68 | 18 | 130 | 90 | 300 | 250 | 190 | 240 | 40 | 18 | M16 / 25 |
(1) 200 kN compact version
(2) 200 kN standard version
DIMENSIONS in millimeters – 1 MN capacity
DIMENSIONS in millimeters – 2 MN capacity
Weigh Module
SPECIFICATIONS
| Parameter | Value |
|---|---|
| Rated load (RL) | 20, 50, 100, 200(1), 300, 400, 500, 1000, 2000 kN |
| Temperature range | –40 to +80 °C |
| Temperature effect on output (–10 °C to +50 °C) | ±0.005% of output / °C |
| Nonlinearity | ±0.075% RO |
| Repeatability | 0.02% RO |
| Temperature effect on zero balance (–10 °C to +50 °C) | ±0.005% of RO / °C |
| Load, safe | 150% RL |
| Load, ultimate | 200% RL |
| Insulation resistance at 200 VDC | > 4 GΩ |
| Side load, safe | 50% RL (2) |
| Uplift load, safe | 50% RL (2) |
| Material | Stainless steel load cell, plated steel bracket (stainless optional) |
| Input voltage, recommended | 5 VDC or VAC |
| Input voltage, maximum | 18 VDC or VAC |
| Electrical connection | 10 m shielded four conductor cable |
| Input resistance | 382 Ω ±5 Ω |
| Degree of protection | IP67 |
| Output resistance | 350 Ω ±0.5 Ω |
| Rated output (RO) | 1.0 mV/V |
| Approvals | cFMus, ATEX, IECEx, EN1090 Exc 2 certified versions available upon request |


Reviews
There are no reviews yet.