BLH NOBEL / KIS-1 Load Cell/Weigh Module

The KIS-1 load cell has several features that clearly distinguish it from other load cells. It is easy to install and extremely accurate, even when subjected to dynamic process forces and severe environmental conditions. Due to the double cantilever design it can have a floating load point and is not affected by side forces up to 100%. This makes it non sensitive to thermal expansions, vibrations and disturbant side force. All KIS load cells can be ATEX/IECEx/cFMus certified for use in explosive atmospheres.

Brand:

Description

KIS-1 Load Cell/Weigh Module

Features
Capacity range: 50, 100, 200, 300, and 500kN (11.2K, 22.4K, 44.9K, 67.5K, and 112.4Klb)
Simple installation
Moveable load point
Withstands very high lateral forces
Extremely accurate and rugged
ATEX/IECEx/cFMus certified for hazardous locations

Application: Process Weighing & Batching,Strip & Web Tension,Hazardous Areas
Certificates: ATEX,IECEx,cFMus
Combined Error: 0-0.05 %
Environment Protection Class: IP67,IP66,IP65,IP54,IP20
Industry: Offshore,Metal,Mining,Pulp & Paper,Chemical,Pharmaceutical,Food & Beverage
Material: Stainless Steel,Plated Steel
Max Capacity: k lb: 25-115
Max Capacity: kN: 100-500
Max Capacity: ton: 10-50
Product Type: Weigh Modules & Load Cells,Force Transducers & Tension Measurement Modules

OUTLINE DIMENSIONS

RANGE

kN (lb)

ØA ØB ØC D E F G H J K L ØM N P R S T
50

(11.2k)

77

(3.03)

75

(2.95)

70

(2.76)

288

(11.46)

93

(3.66)

65

(2.56)

141.3

(5.56)

12

(.47)

5

(.20)

2.65

(.10)

2.65

(.10)

9.1

(.36)

14

(.55)

7

(.28)

110

(4.33)

20

(.79)

60

(2.36)

100

(22.4k)

92

(3.62)

90

(3.54)

82

(3.23)

312

(12.40)

107

(4.21)

65

(2.56)

155.4

(6.12)

15

(.59)

6

(.24)

2.65

(.10)

3.15

(.12)

12.6

(.50)

17

(.67)

8

(.31)

120

(4.72)

20

(.79)

70

(2.76)

200

(44.9k)

101

(3.98)

100

(3.94)

90

(3.54)

343

(13.62)

130

(5.04)

65

(2.56)

175.8

(6.92)

15

(.59)

6

(.24)

3.15

(.12)

3.15

(.12)

15.7

(.62)

19

(.75)

8.5

(.33)

128

(5.12)

20

(.79)

80

(3.15)

300

(67.5k)

101

(3.98)

100

(3.94)

90

(3.54)

343

(13.62)

130

(5.04)

65

(2.56)

175.8

(6.92)

15

(.59)

6

(.24)

3.15

(.12)

3.15

(.12)

15.7

(.62)

19

(.75)

8.5

(.33)

128

(5.12)

20

(.79)

80

(3.15)

500

(112.4k)

142

(5.59)

140

(5.51)

130

(5.12)

447

(17.72)

168

(6.50)

75

(2.95)

212.8

(8.38)

35

(1.38)

20

(.79)

4.15

(.16)

4.15

(.16)

15.7

(.62)

30

(1.18)

8.5

(.33)

177

(7.09)

27

(1.06)

80

(3.15)

Dimension shown in mm (in)

OUTLINE DIMENSIONS cont

RANGE

kN (lb)

A B C D ØE F G H J K L M ØN P T R S
50 (11.2k) 280

(11.02)

150

(5.91)

30

(1.18)

152

(5.98)

16

(0.63)

115

(4.53)

245

(9.65)

65

(2.56)

45,5

(1.79)

115

(4.53)

150

(5.91)

72

(2.83)

18

(0.71)

30

(1.18)

30

(1.18)

M16 M16 43

(1.69)

100 (22.4k) 310

(12.20)

170

(6.69)

40

(1.57)

173

(6.81)

22

(0.87)

130

(5.12)

270

(10.63)

65

(2.56)

63

(2.48)

126

(4.96)

160

(6.30)

85

(3.35)

22

(0.87)

40

(1.57)

26

(1.02)

M20 M20 50

(1.97)

200 (44.9k) 340

(13.39)

180

(7.09)

50

(1.97)

199

(7.83)

25

(0.98)

140

(5.51)

300

(11.81)

65

(2.56)

71

(2.80)

146

(5.75)

190

(7.48)

95

(3.74)

25

(0.98)

49

(1.97)

32

(1.26)

M24 M24 57

(2.24)

300* (67.5k) 340

(13.39)

180

(7.09)

50

(1.97)

199

(7.83)

25

(0.98)

140

(5.51)

300

(11.81)

65

(2.56)

71

(2.80)

175

(6.89)

220

(9.02)

105

(4.13)

26

(1.02)

53

(2.09)

32

(1.26)

M24 M24 56

(2.20)

500* (112.4k) 480

(18.90)

280

(11.02)

60

(2.36)

315

(12.40)

33

(1.30)

220

(8.66)

420

(16.54)

75

(2.95)

108

(4.25)

240

(9.45)

300

(11.81)

150

(5.91)

26

(1.02)

68

(2.76)

60

(2.36)

M24 M24 91

(3.58)

RANGE

kN (lb)

V
50 M16-2X120 (4.724) LG
100 M20-2.5X140 (5.512) LG
200 M24-3X160 (6.299) LG
300 Not available
500 Not available

Dimension shown in mm (in)

SPECIFICATIONS
PARAMETER VALUE
PERFORMANCE
Rated load (RL) 50, 100, 200, 300, 500 kN
Combined error (terminal) ±0.03% RO
Repeatability 0.01% RO
Overload,* safe 200% RL, 150% RL for 300 kN and 500 kN
Overload,* ultimate 300% RL, 200% RL for 300 kN
Uplift, safe 70% RL
Uplift, ultimate 85% RL
Side load,* safe 100% RL, 50% RL for 300 kN and 500 kN
Side load,* ultimate 200% RL, 100% RL for 300 kN and 500 kN
Input voltage, recommended 5-10 VDC or VAC
Input voltage, maximum 18 VDC or VAC
Input resistance 350 Ω ±3 Ω
Output resistance 350 Ω ±0.5 Ω
Rated output (RO) 2.040 mV/V
Tolerance of RO ±0.1% RO
Zero balance ±1% RO
Tolerance of shunt calibration values 0.1% of value; actual output deined on unit calibration sheet
Creep at RL after 30 minutes ±0.04% RL
Temperature range

(wider temperature range available upon request)

–40 to +105°C

–40 to +220°F

Temperature effect, on output (–10°C to +50°C) ±0.0015% of output/°C

±0.0008% of output/°F

Temperature effect, on zero balance (–10°C to +50°C) ±0.003% RO/°C

±0.0017 % RO/°F

Insulation resistance at 200 VDC >4 GΩ
Material: load cell, 50 kN Stainless steel (Nobel version), yellow chromate steel (BLH version)
Material: load cell, 100–500 kN Yellow chromate steel, stainless steel as an option
Material: bracket, yoke and tilt guard Yellow chromate steel, stainless steel as an option
Electrical connection 10m shielded four conductor cable
Degree of protection IP67
APPROVALS
ATEX, IECEx and cFMus certiied versions are available upon request.

* Referring to recommended loading point
BLH Nobel is continually seeking to improve product quality and performance. Speciications may change accordingly.

Reviews

There are no reviews yet.

Be the first to review “BLH NOBEL / KIS-1 Load Cell/Weigh Module”