Description
LOC Low Profile Off-Center Single-Point
FEATURES
- Capacities: 5 to 1000 kg
- Cost-effective load cell for scales of simple construction
- Anodized aluminum alloy
- NTEP Class III 5000S approval (5 kg to 500 kg)
- OIML C3 approval (5 kg to 500 kg)
- OIML C6 approval (500 kg to 1000 kg)
- Optional – FM approval available
- Stainless steel version available
APPLICATIONS
- Platform scales (single load cell)
- Packaging machines
- Dosing / Filling
- Belt scales / Conveyor scales
- In-motion check weigher
OUTLINE DIMENSIONS in inches (millimeters)

| Type | Capacity | L | L1 | L2 | W | W1 | H | H1 |
|---|---|---|---|---|---|---|---|---|
| SE | 5 / 7 / 10 / 15 / 20 / 30 / 50 / 60 / 75 / 100 / 150 kg | 150.0 (5.91) | 19.0 (0.75) | 100.0 (3.94) | 30.0 (1.18) | 24.0 (0.94) | 39.5 (1.56) | 19.0 (0.75) |
| ME | 50 / 100 / 150 / 250 / 300 / 500 / 635 / 800 kg | 174.0 (6.85) | 19.0 (0.75) | 122.0 (4.80) | 60.0 (2.36) | – | 30.0 (1.18) | 65.0 (2.56) |
| LE | 100 / 150 / 250 / 300 / 500 / 635 / 800 / 1000 kg | 191.0 (7.52) | 25.0 (0.98) | 125.0 (4.92) | 76.2 (3.00) | – | 60.0 (2.36) | 75.0 (2.95) |
Low Proile Off-Center Single-Point
| SPECIFICATIONS | |||||
| PARAMETER | VALUE | UNIT | |||
| NTEP/OIML accuracy class | NTEP III* | Non-Approved | C3** | C6*** | |
| Maximum no. of intervals (n) | 5000 single | 1000 | 3000 | 6000 | |
| Y = Emax/Vmin | 8000 | 1400 | 10000 | 12000 | Maximum available |
| Standard capacities (Emax) | 5, 7, 10, 15, 20, 30, 50, 60, 75,
100, 150, 250, 300, 500, 635, 800, 1000 |
kg | |||
| Rated output—R.O. | 2.0 | mV/V | |||
| Rated output tolerance | 10 | ±% of rated output | |||
| Zero balance | 1 | ±% of rated output | |||
| Non-linearity | 0.020 | 0.025 | 0.020 | 0.015 | ±% of rated output |
| Hysteresis | 0.020 | 0.025 | 0.020 | 0.015 | ±% of rated output |
| Non-repeatability | 0.020 | ±% of rated output | |||
| Creep error (20 minutes) | 0.021 | 0.030 | 0.025 | 0.012 | ±% of rated output |
| Zero return (20 minutes) | 0.01 | 0.030 | 0.017 | 0.008 | ±% of rated output |
| Temperature effect on min. dead load output | 0.0026 | 0.0026 | 0.0014 | 0.0012 | ±% of rated output/°C |
| Temperature effect on sensitivity | 0.0010 | 0.0015 | 0.008 | 0.008 | ±% of applied output/°C |
| Compensated temperature range | –10 to +40 | °C | |||
| Operating temperature range | –20 to +60 | °C | |||
| Safe overload | 150 | % of R.C. | |||
| Ultimate overload | 200 | % of R.C. | |||
| Excitation, recommended | 10 | VDC or VAC RMS | |||
| Excitation, maximum | 15 | VDC or VAC RMS | |||
| Input impedance | 410±10 | Ω | |||
| Output impedance | 350±3 | Ω | |||
| Insulation resistance | >5000 | MΩ | |||
| Construction | Anodized aluminum. Stainless steel available. | ||||
| Environmental protection | IP66 | ||||
* Capacities 5–500 kg
** Capacities 5–500 kg
*** Capacities 500–1000 kg
All speciications are subject to change without notice.


Reviews