METTLER TOREDO / SLC611D / POWERCELL PDX Load Cell

• µP controlled accuracy
• Robust output signal
• 10V/m EMC protection
• No junction box connections
• OIML C3 accuracy
• NTEP IIIM 5K accuracy
• Stainless steel
• IP68, IP69K protection class

Brand:

Description

SLC611D POWERCELL® PDX Load Cell

The SLC611D POWERCELL® is approved for use in various applications in Europe, Asia, America and almost everywhere else in the world. If an approval is required, the SLC611D POWERCELL® already complies.

Tank Weighing
The capacity range from 7.5t to 22.5t allows the weighing of tanks and silos. The stainless steel design, hermetic sealing and IP68/IP69K protection provides the best reliability in tank and hopper weighing applications.

Load Cells
POWERCELL® load cells have a rocker-pin design that automatically aligns load forces for accurate weighing. These hermetically sealed load cells are rated IP68/IP69K and can be used in all environments.

PowerMountTM Weigh Module
The optional METTLER TOLEDO PowerMountTM weigh module allows one to convert an existing system into a precise weighing system. It is ideal for applications such as tanks scales, belt scales and conveyor scales. Available in zinc plated steel or stainless steel.

Predictive Maintenance
SLC611D monitors single load cells for overload, zero drift, foundation problems, etc.; prompting action before system shuts down or measures incorrectly.

Parameter Unit of Measure Specification
Trade Name POWERCELL PDX
Model Number SLC820
Load Cell Type Column Compression, Digital Weight Processor (DWP)
Part Number 42904882 42904883 42904884 42904885 42904891 42904892 30290638 72238150 72238147 30220694 30314022
Rated Capacity (R.C.)1 t (klb, nominal) 20 (44.1) 30 (66.2) 50 (110.3) 90 (198.5) 200 (440) 300 (660)
Sensitivity at R.C. d @ R.C. 200,000 300,000 500,000 900,000 200,000 300,000
Communication Controller Area Network (CAN), Encrypted
Communication Rate kbit/sec 125
Effective System Update Rate Hz 83 (with 4 cells), 50 (with 6 cells), 25 (with 14 cells), 15 (with 24 cells)
Effective System Synchronous Update Rate Hz 40 (with 10 cells)
Weighing Performance
Effect of Cable Length on System Accuracy kg 0 (Digital Signal)
Compensated2 °C (°F) -10 to +40 (+14 to +104)
Temperature Range Operating3 °C (°F) -50 to +55 (-58 to +131)
Safe Storage °C (°F) -40 to +80 (-40 to +176)
Warm-up Time from Cold Start minutes 15
Class C3/IIIL-M C3/IIIL-M C4/IIIL-M C6 C3/IIIL-M C4/IIIL-M C6 C3/IIIL-M C4/IIIL-M C1 C1
Metrology Linearity4 ppm R.C. < 100 < 100 < 100 < 67 < 100 < 100 < 67 < 100 < 100 < 140 < 140
Hysteresis4 ppm R.C. < 160 < 160 < 160 < 110 < 160 < 160 < 110 < 160 < 160 < 220 < 220
Span4 ppm R.C./°C < ±13.3 < ±13.3 < ±10.0 < ±6.6 < ±13.3 < ±10.0 < ±6.6 < ±13.3 < ±10.0 < ±26.7 < ±26.7
Temperature Effect on Combined Error4 ppm R.C. < 300 < 300 < 300 < 200 < 300 < 300 < 200 < 300 < 300 < 800 < 800
Creep at R.C. 10s to 30m ppm R.C. < ±150 < ±150 < ±125 < ±83 < ±150 < ±125 < ±83 < ±150 < ±125 < ±500 < ±500
Zero Return After 30 min at R.C. ppm R.C. < ±150 < ±150 < ±125 < ±83 < ±150 < ±125 < ±83 < ±150 < ±125 < ±500 < ±500
Barometric Pressure Effect on Zero Load Output kg/kPa < ±0.95 < ±0.93 < ±0.93 < ±0.93 < ±1.5 < ±1.5 < ±1.5 < ±2.4 < ±2.4 < ±7.7 < ±11.3
Zero Balance %R.C. @ 20°C < ±0.2
Temperature Effect on Minimum Dead Load Output kg/°C < ±0.8*Vmin(OIML)/5°C
Humidity Effect, Continuous 100% RH kg 0 (Hermetic Seal)
Nonrepeatability ppm R.C. < ±50 < ±200
Metrological Approvals
Standard OIML R60
Number T8426; TC7579; T2206; R60/2000-NL1-09:08
Class C3 C3 C4 C6 C3 C4 C6 C3 C4 C1 C1
nmax (OIML) 3000 3000 4000 6000 3000 4000 6000 3000 4000 1000 1000
Y kg/kg 8000 11,111 12,500 20,000 11,111 12,500 20,000 11,111 14,286 10,000 30,000
Vmin (OIML) kg 2.5 2.7 2.4 1.5 4.5 4 2.5 8.1 6.3 20 30
European/OIML Approval5 pLC 0.8
Humidity Symbol CH (Hermetic Seal)
Min. Dead Load kg 50
Standard NIST Handbook 44
Number NTEP 08-090
Class III L-M
nmax (HB44) 10,000 5000
NTEP Approval5 Vmin (HB44) kg (lb, nominal) 0.95 (2.1) 1.0 (2.2) 0.93 (2.0) 1.7 (3.8) 1.55 (3.4) 3.2 (7.1) 2.4 (5.3) 7.7 (17) 11.3 (25)
Min. Dead Load kg (lb, nominal) 50 (110.3)
1 R.C. = Rated or full capacity as specified on the data plate.
2 Certified according to approval agency or notified body (third party).
3 Operating temperatures below -40°C/-40°F require the load cell to be continuously powered.
4 The combined error of span, linearity error, and hysteresis will not exceed 80% of the error limits for OIML R60. OIML R60 C3 error limits are typically 60% tighter than the HB44 10K III L-M allowable tolerance.
5 See certificate for complete information.
Part Number 42904882 42904883 42904884 42904885 42904891 42904892 30290638 72238150 72238147 30220694 30314022
Rated Capacity (R.C.) t (klb, nominal) 20
(44.1)
30 (66.2) 50 (110.3) 90 (198.5) 200
(440)
300
(660)
Electrical
Connectors Quick-Connect with Bayonet Lock, 5 Pins, Stainless Steel, Glass-to-Metal Seal, Laser Welded
Cable Exterior Braided Stainless Steel Armor, PVC Chemically Resistant Jacket, 9mm O.D., 5 Conductors, Triple Shielded and Dual Drain Wires
Cable Length, Cell to Cell (typical) m (ft, nominal) 2 to 14 (6.5 to 46)
Cable Length, Home Run (typical) m (ft, nominal) 10 to 300 by 10 increments (33 to 984 by 33 increments)
Supply Voltage by Terminal (Regulated in the Load Cell) Typical V DC 12 or 24
Minimum/Maximum V DC 7.5 / 28
Lightning Protection6 Max. Tested (SAE ARP5412) A > 80,000
Surge Protective Device Integral
Insulation Resistance at 50VDC ≥ 2000
Breakdown Voltage V AC ≥ 500
Mechanical
Spring Element 17-4 PH Stainless Steel (magnetic) 420 Stainless Ste
Enclosure Electropolished 304 Stainless Steel, 1mm Wall Thickness, Laser Welded
Material Low-Profile Receivers 17-4 PH Forged and Machined Stainless Steel, Hardened
Anti-Rotation Integral, 6-Point Hexagonal Mount
Type Hermetic (submersible)
Protection IP Rating IP68 (1m – 7 days submersion), IP69K test reports on file
NEMA Rating NEMA 6P (submersible)
Safe %R.C. 200 150
Load Limit Ultimate %R.C. 300 200
Safe Dynamic Load %R.C. 70
Fatigue Life at R.C. Cycles > 1,000,000
Direction of Loading Compression
Deflection at R.C., typical mm (in) 0.36
(0.014)
0.51 (0.020) 0.71 (0.028) 1.02 (0.040)
Horizontal Restoring Force %A.L./mm7 1.82 1.82 1.82 1.6 1.59
Shipping Weight, nominal kg (lb) 3.0
(6.6)
3.0 (6.6) 3.2 (7.0) 7.5 (16.6) 12.8
(28.2)
29
(63.9)
6 Tested with an IND780 terminal and lightning protection kit by Lightning Technologies, Inc. (80,000A).
7 Percent of the vertical applied load (A.L.) per mm of horizontal displacement.Country of origin: Designed by METTLER TOLEDO in Switzerland and made in China.
Part Number 42904882 42904883 42904884 42904885 42904891 42904892 30290638 72238150 72238147 30220694 30314022
Rated Capacity (R.C.) t (klb, nominal) 20
(44.1)
30 (66.2) 50 (110.3) 90 (198.5) 200
(440)
300
(660)
Hazardous Area
ATEX
Zone 1/21
Agency FM Approvals Ltd.
Certificate Number FM17ATEX0023
Standards EN 60079-0:2012+A11:2013, EN 60079-11:2012, EN 60529:1991+A1:2000+A2:2013
Gas Rating II 2 G Ex ib IIB T4 Gb
Dust Rating II 2 D Ex ib IIIC T130°C Db
IS Parameters Power: Ui = 8.4V, Ii = 100mA, Pi = 0.84W, Ci = 27.5uF, Li = 17.7uH CANbus: Ui = 8.4V, Ii = 100mA, Pi = 0.84W, Ci = 27.5uF, Li = 0uH
Temperature Range -40°C ≤ Ta ≤ +55°C
Installation Instructions 30343366
IECEx
Zone 1/21
Agency FM Approvals LLC
Certificate Number IECEx FMG 17.0010
Standards IEC 60079-0:2011 Edition 6.0, IEC 60079-11:2011 Edition 6.0
Gas Rating Ex ib IIB T4 Gb
Dust Rating Ex ib IIIC T130°C Db
IS Parameters Power: Ui = 8.4V, Ii = 100mA, Pi = 0.84W, Ci = 27.5uF, Li = 17.7uH CANbus: Ui = 8.4V, Ii = 100mA, Pi = 0.84W, Ci = 27.5uF, Li = 0uH
Temperature Range -40°C ≤ Ta ≤ +55°C
Installation Instructions 30343366
FM
Division 1 Zone 1/21
Agency FM Approvals LLC
Certificate Number FM17US0025
Standards FM Class 3600:2011, FM Class 3610:2015, FM Class 3810:2005 ANSI/ISA 60079-0:2013, ANSI/ISA 60079-11:2014, ANSI/IEC 60529:2004
Gas Rating Class I, Division 1, Groups C, D, Temperature Class T4 Class 1, Zone 1, AEx ib IIB T4 Gb
Dust Rating Class II, Division 1, Groups E, F, G, Temperature Class T4 Zone 21, AEx ib IIIC T130°C Db
Fiber Rating Class III, Division 1
IS Parameters Power: Ui = 8.4V, Ii = 100mA, Pi = 0.84W, Ci = 27.5uF, Li = 17.7uH CANbus: Ui = 8.4V, Ii = 100mA, Pi = 0.84W, Ci = 27.5uF, Li = 0uH
Temperature Range -40°C ≤ Ta ≤ +55°C
Control Drawing 30343367
CSA
Division 1 Zone 1/21
Agency FM Approvals LLC
Certificate Number FM17CA0013
Standards CAN/CSA-C22.2 No. 60079-0:2015, CAN/CSA-C22.2 No. 60079-11:2014 CAN/CSA-C22.2 No. 61010-1:2012, CSA-C22.2 No. 60529:R2016
Gas Rating Class I, Division 1, Groups C, D, Temperature Class T4 Zone 1, Ex ib IIB T4 Gb
Dust Rating Class II, Division 1, Groups E, F, G, Temperature Class T4 Zone 21, Ex ib IIIC T130°C Db
Fiber Rating Class III, Division 1
IS Parameters Power: Ui (Vmax) = 8.4V, Ii (Imax) = 100mA, Pi = 0.84W, Ci = 27.5uF, Li = 17.7uH CANbus: Ui (Vmax) = 8.4V, Ii (Imax) = 100mA, Pi = 0.84W, Ci = 27.5uF, Li = 0uH
Temperature Range -40°C ≤ Ta ≤ +55°C
Control Drawing 30343367
ATEX
Zone 2/22
Agency DEKRA Certification B.V.
Certificate Number KEMA 09ATEX0063
Standards EN 60079-0:2012, EN 60079-15:2010, EN 60079-31:2014
Gas Rating II 3 G Ex nA IIC T6 Gc
Dust Rating II 3 D Ex tc IIIC T85°C Dc IP6X
Parameters Power and CANbus: Umax = 26.4V, Imax = 2A, Pmax = 0.5W / Load Cell
Temperature Range  -40°C ≤ Ta ≤ +55°C
Installation Instructions 61045275
IECEx
Zone 2/22
Agency DEKRA Certification B.V.
Certificate Number IECEx KEM 09.0028
Standards IEC 60079-0:2011 Edition 6.0, IEC 60079-15:2010 Edition 4, IEC 60079-31:2008 Edition 1
Gas Rating Ex nA IIC T6 Gc
Dust Rating Ex tc IIIC T85°C Dc IP6X
Parameters Power: Umax = 26.4V, Imax = 2A, Pmax = 0.5W / Load Cell
Temperature Range  -40°C ≤ Ta ≤ +55°C
Installation Instructions 61045275
UL
Division 2
Agency Underwriters Laboratories Inc.
Certificate Number 2011-06-14-E152336
Standards UL 508 Edition 17, ANSI/ISA 12.12.01-2007
Gas Rating Class I, Division 2, Groups C, D
Dust Rating Class II, Division 2, Groups F, G
Fiber Rating Class III
NIFW Parameters Power: Vmax = 26.4V, Imax = 60mA, Ci = 11nF, Li = 0uH CANbus: Vmax = 26.8V, Imax = 4mA, Ci = 0.602nF, Li = 0uH
Temperature Range  -40°C ≤ Ta ≤ +55°C
Control Drawing 42700274
CSA
Division 2
Agency Underwriters Laboratories Inc.
Certificate Number 2011-06-14-E152336
Standards CAN/CSA-C22.2 No. 213-M1987 Edition 1, CAN/CSA-C22.2 No. 157-92, CAN/CSA-C22.2 No. 142-M1987
Gas Rating Class I, Division 2, Groups C, D
Dust Rating Class II, Division 2, Groups F, G
Fiber Rating Class III
NIFW Parameters Power: Vmax = 26.4V, Imax = 60mA, Ci = 11nF, Li = 0uH CANbus: Vmax = 26.8V, Imax = 4mA, Ci = 0.602nF, Li = 0uH
Temperature Range  -40°C ≤ Ta ≤ +55°C
Control Drawing 42700274

SLC611D POWERCELL® Dimensional Drawings mm [in]

SLC611D POWERCELL® Order Information

Item No., load cell
Rated capacity Class
C3/III M n:5
7.5t 30092515
15t 30092516
22.5t 30092517

Bolded entries are stocked

SLC611D POWERCELL® Home Run Cable

Colour Function
Yellow Shield
Blue CAN_L
White CAN_H
Red V +
Black V –

SLC611D POWERCELL® Order Information, Cables

Item No.
Description Cable, material / length
PU / 3m (10ft) PU / 5m (16.4ft) PU / 10m (32.8ft) PU / 20m (65.6ft) PU / 30m (98.4ft) PU / 50m (164ft) PU / 100m (333ft) PU / 150m (500ft)
Cable kit, 3 load cells 30302750 30302751 30302752 30302753
Cable kit, 4 load cells 30302754 30302755 30302756 30302757
Load cell – load cell cable 30302766 30302767 30302768 30302769
Home Run Cable 30302758 30302759 30302760 30302761 30302762 30302763 30302764
Cable extension adapter 30220628
CAN termination load cell 30302770
Blind cap connector load cell 30302771
Cable gland for home run cable with IND780PDX 30095639

Bolded entries are stocked

Reviews

There are no reviews yet.

Be the first to review “METTLER TOREDO / SLC611D / POWERCELL PDX Load Cell”