Minebea intec / Compression load cell PR 6202 and mounting kit PR 6002

The compression load cells in the PR 6202 series are specially developed for the complex demands of the food, pharmaceutical and chemical industry. Together with the mounting kits in the PR 6002 series, they are characterised by simple cleaning and safe inspection, and therefore offer the optimal hygienic design for silo and vessel weighing.

Brand:

Description

Compression load cell PR 6202 and mounting kit PR 6002

Hygienic design for silo and vessel weighing

Technical specifications

Compression load cell PR 6202

Parameter Description Abbr. C1 C3 C4 Unit
Accuracy class     0.03 0.015 0.012 %Emax
Minimum dead load Lowest limit of specified measuring range Emin 0 0 0 %Emax
Maximum capacity Highest limit of specified measuring range Emax See ordering information table kg
Safe load limit Maximum load without irreversible damage Elim 150 150 150 %Emax
Destructive load Danger of mechanical destruction Ed >300 >300 >300 %Emax
Minimum LC verification

Minimum load cell verification interval; vmin = Emax/Y

For Emax = 2 t

Y Y

5,000

5,000

14,000

10,000

16,000

/

 
Deadload output return Factor for deadload output return after load (DR=1/2*Emax/Z) Z 1,000 3,000 4,000  
Rated output Relative output at maximum capacity Cn 2 mV/V
Tolerance on rated output Permissible deviation from rated output dc <0.25 <0.07 0.07 %Cn
Zero output signal Load cell output signal under unloaded condition Smin <1.0 <1.0 <1.0 %Cn
Reproducibility Max. change in load cell output for repeated loading R <0.01 <0.005 <0.005 %Cn
Creep Max. change of output signal under Emax during 30 min. dcr <0.03 <0.015 <0.0125 %Cn
Non-linearity Max. deviation from best straight line through zero dLin <0.03 <0.01 <0.01 %Cn
Hysteresis Max. difference in LC output between loading and unloading dhy <0.03 <0.015 <0.0125 %Cn
Temperature effect (TK) on Smin Max. change of Smin in BT TKSmin <0.028 <0.01 <0.007 %Cn/10 K
Temperature effect (TK) on C Max. change of C in BT TKC <0.02 <0.01 <0.008 %Cn/10 K
Input impedance Between supply terminals RLC 1,080±10
Output impedance Between measuring terminals RO 1,010±2 1,010±1 1,010±1
Insulation impedance Between measuring circuit and housing at 100 VDC RIS >5,000 ×106
Insulation voltage Between circuit and housing (PR 62../..E only) 500 V
Recommended supply voltage To hold the specified performance Bu 4…24 V
Max. supply voltage Permissible for continuous operation without damage Umax 32 (EX versions: 25) V
Nominal ambient temp. range To hold the specified performance BT -10…+70 -10…+55 -10…+55 °C
Usable ambient temp. range Permissible for continuous operation without damage BTU -40…+95 °C
Storage temperature range Without electrical and mechanical stress BTI -40…+95 °C
Permissible inclination Permissible displacement from nominal load line Sex 10 mm
Vibration resistance Resistance against oscillations (IEC 68-2-6 Fc) 20 g,100 h, 10…150 Hz
Barometric pressure influence Influence of barometric pressure on output PKSmin 1 t…10 t: 190/25 t…50 t: 390 g/kPa
Nominal deflection Max. elastic deformation under nominal load Snom

Up to 6 t: ≤ 0.3

Up to 25 t: ≤ 0.5

50 t: ≤0.8

mm
Material (load cell housing) Stainless steel 1.4404 acc. DIN EN 10088-3 (conforms to 316L AISI/SAE)
Protection class IP68 / IP69
Cable

Length: Emax ≤10 t: 5 m, Emax >10 t: 12 m Diameter: 5 mm

Cross section: 4 × 0.35 mm2 Material cable sheath: TPE

Bending radius

≥ 25 mm at fixed installation

≥ 75 mm at flexible installation

Mounting kit PR 6002
Maximum capaci- ty of load cell Mounting kit// accessories Material Description/comments Mounting screws Installation height (mm) Max. permissible horizontal force (kN) Max. permissible lift-off force [kN] Max. permissible eccentricity Max. permissible vertical load with- out load cell
1 t–10 t PR 6002/00S Stainless steel 1.4542 Upper and lower load disc / 160.5 / / / /
PR 6002/02S

Stainless

steel 1.4301 (AISI

304)

Plate mounting kit incl. upper and lower load disc M12 190.5 / / / /
PR 6002/04S Plate mounting kit incl. load discs, lift-off and fall protection M12 / 25 ± 5 mm 2.5 t
PR 6002/10S FlexLOCK M12 25 25 ± 5 mm 2.5 t
25 t–50 t PR 6002/01S Stainless steel 1.4542 Upper and lower load disc / 160.5 / / / /
PR 6002/03S

Stainless

steel 1.4301 (AISI

304)

Plate mounting kit incl. upper and lower load disc M12 190.5 / / / /
PR 6002/05S Plate mounting kit incl. load discs, lift-off and fall protection M12 / 25 ± 5 mm

2.5 t

(10 t*)

PR 6002/11S FlexLOCK M12 25 25 ± 5 mm

2.5 t

(10 t*)

* max. permissible vertical load with transport protection (supports)

Technical diagrams

Compression load cell PR 6202 (1 t … 10 t)

Compression load cell PR 6202 (25 t … 50 t)

 

Mounting kit PR 6002/00S

Mounting kit PR 6002/01S

Mounting kit PR 6002/02S

Mounting kit PR 6002/03S

Mounting kit PR 6002/04S

Mounting kit PR 6002/05S

FLEXLOCK mounting kit PR 6002/10S

FLEXLOCK mounting kit PR 6002/11S

 

Ex approval

Scope of validity:

PR 6202/… E (1 t … 50 t)

Hygiene certificate compression load cell PR 6202
Zone Labelling Certificate number For
0 and 1

II 1G Ex ia IIC T6 Ga

Ex ia IIC T6 Ga

BVS 16 ATEX E 005

IECEx BVS 16.0005

PR 6202/ … E
20 and 21 II 1D Ex ta IIIC T160 °C Da Ex ta IIIC T160°C Da TÜV 03 ATEX 2301 X IECEx TUN 17.0025X all PR 6202
2 and 22

II 3G Ex nA IIC T6 Gc

II 3D Ex tc IIIC T85 °C Dc

Manufacturer’s declaration all PR 6202

FMus

class I, II, III div. 1 + 2

IS CL I, II, III, DIV 1, GP A,B,C,D,E,F,G Entity – 4012 101 5688

NI CL I, II, III, DIV 2, GP A,B,C,D,E,F,G – 4012 101 5688; NIFW

T4A Ta= -30°C to 70°C; T5 Ta= -30°C to 55°C

FM17US0276 all PR 6202

FMca

class I, II, III div. 1 + 2

IS CL I, II, III, DIV 1, GP A,B,C,D,E,F,G Entity – 4012 101 5688

NI CL I, II, III, DIV 2, GP A,B,C,D, E, F, G – 4012 101 5688; NIFW

T4A Ta= -30°C to 70°C; T5 Ta= -30°C to 55°C

FM17CA0138 all PR 6202

Ordering information

The accuracy class of the compact compression load cell PR 6211 is classified and checked in accordance with OIML R60.

Compression load cells, accuracy class C1=0.03%
Type Order number
PR 6202/1tC1 940520202210
PR 6202/2tC1 940520202220
PR 6202/4tC1 940520202240
PR 6202/6tC1 940520202260
PR 6202/10tC1 940520202310
PR 6202/25tC1 940520202325
PR 6202/50tC1 940520202350
Compression load cells, accuracy class C1=0.03%, EX version
Type Order number
PR 6202/1tC1E 940560202210
PR 6202/2tC1E 940560202220
PR 6202/4tC1E 940560202240
PR 6202/6tC1E 940560202260
PR 6202/10tC1E 940560202310
PR 6202/25tC1E 940560202325
PR 6202/50tC1E 940560202350
Compression load cells, accuracy class C3=0.015%
Type Order number
PR 6202/2tC3 9405202 03220
PR 6202/4tC3 940520203240
PR 6202/6tC3 940520203260
PR 6202/10tC3 940520203310
PR 6202/25tC3 940520203325
PR 6202/50tC3 940520203350
Compression load cells, accuracy class C3= 0.015%, EX version
Type Order number
PR 6202/2tC3E 940560203220
PR 6202/4tC3E 940560203240
PR 6202/6tC3E 940560203260
PR 6202/10tC3E 940560203310
PR 6202/25tC3E 940560203325
PR 6202/50tC3E 940560203350
Compression load cells, accuracy class C4=0.012%
Type Order number
PR 6202/4tC4 940520204240
PR 6202/6tC4 940520204260
PR 6202/10tC4 940520204310
PR 6202/25tC4 940520204325
PR 6202/50tC4 940520204350
Compression load cells, accuracy class C4=0.012%, EX version
Type Order number
PR 6202/4tC4E 940560204240
PR 6202/6tC4E 940560204260
PR 6202/10tC4E 940560204310
PR 6202/25tC4E 940560204325
PR 6202/50tC4E 940560204350
Load disc kits for compression load cell PR 6202
Type Order number
PR 6002/00S (1 t–10 t) 940536002002
PR 6002/01S (25 t–50 t) 940536002012
Plate mounting kits, not incl. constrainer, for mounting kit PR 6002
Type Order number
PR 6002/02S (1 t–10 t) 940536002022
PR 6002/03S (25 t–50 t) 940536002032
PR 6002/04S (1 t–10 t) 940536002042
PR 6002/05S (25 t–50 t) 940536002052
FLEXLOCK mounting kits with integrated constrainer for mounting kit PR 6002
Type Order number
PR 6002/10S (1 t–10 t) 940536002102
PR 6002/11S (25 t–50 t) 940536002112

 