Minebea intec / Load Cell Pendeo® Truck Digital weighing technology for reliable vehicle weighing

Advantages

  • Easy commissioning
  • Efficient use due to transparent data
  • Quick repair and maintenance
  • Extremely resistant
Category:
Brand:

Description

Load Cell Pendeo® Truck Digital weighing technology for reliable vehicle weighing

The digital load cells in the Pendeo® Truck series are specially designed for vehicle weighing. They are designed such that, when combined with mounting kits, they can compensate for movement of the bridge structure. In combination with “DAT – Digital Assistance Technology” from Minebea Intec, the Pendeo® Truck also allows for the recording of valuable data about the weighing process.

Proven Minebea Intec technology for a wide range of applications

  • Robust design ensures insensitivity to vibration and enables load capacities from 20 to 75 tonnes.
  • Faster commissioning and shorter service times thanks to digital data processing
  • High corrosion resistance due to high quality steel alloys ensures extremely long service life
  • Perfectly matched weighing electronics complete the digital measurement chain.

Technical specifications

General technical data for load cell Pendeo® Truck PR 6224B
Parameters Description Abbr. C3 C6 Unit
Accuracy class     0.015 0.008 %Emax
Minimal dead load Lowest limit of specified measuring range Emin 0 %Emax
Maximum capacity Highest limit of specified measuring range Emax 25, 50, 75 t
Safe load limit Maximum load possible without irreversible damage Elim 25 t, 50 t: 150
75 t: 100
%Emax
Destructive load Danger of mechanical destruction Ed 25 t, 50 t: >300
75 t: >200
%Emax
Minimum LC verification Minimum load cell verification interval, vmin = Emax/Y Y 14,000 20,000  
Deadload output return Factor for deadload output return after load (DR = 1/2*Emax/Z) Z 3,000 8,000  
Rated output Output signal at maximum capacity Cn Standardised to Emax in (t)  
Tolerance on rated output Permissible deviation from rated output dc < 0.07 < 0.07 %Cn
Zero output signal Load cell output signal under unloaded condition Smin 0±1 0±1 %Cn
Reproducibility Max. change of output signal for repeated loading R < 0.005 < 0.005 %Cn
Creep Max. change of output signal at Emax during 30 min. dcr < 0.015 < 0.008 %Cn
Non-linearity1) Deviation from best straight line through zero dLin < 0.01 < 0.01 %Cn
Hysteresis1) Max. difference in between loading and unloading dhy < 0.0165 < 0.008 %Cn
Temperature effect (TK) of Smin Max. change of Smin in BT TKSmin < 0.01 < 0.007 %Cn/10 K
TK of parameter1) Max. change of C in BT TKc < 0.01 < 0.005 %Cn/10 K
Insulation impedance Between measuring circuit and housing at 50 VDC RIS > 1,000 × 106 Ω
Nominal supply voltage range In compliance with the technical data BU 12 to 28 VDC
Nominal ambient temperature range In compliance with the technical data BT -10 to +40 °C
Service temperature range Continuous operation without damage BTU -30 to +70 °C
Storage temperature range Without electrical and mechanical stress BTI -40 to +95 °C
Marginal eccentricity Accepted distance from measuring axis Sex 5 mm
Vibration resistance Resistance against oscillations (IEC 68-2-6-Fc) 20 g, 100 h, 10 to 150 Hz  
Barometric pressure influence Barometric pressure influence on the output signal PKSmin <420 g/kPa
Nominal deflection Max. elastic deforming under maximum capacity Snom 25 t: < 0.5
50 t: < 0.8
75 t: <1.1
mm
Material (housing) Stainless steel 1.4301, AISI 304
Protection class IP66 / IP68 / IP69 (and IP6K6K / IP6K8 / IP6K9K acc. ISO 20653)
Cables Length: 16.5 m
Diameter: 5.8 mm
Cross section: 4 × 0.35 mm2 Material of cable sheathing: TPE
Bending radius ≥ 30 mm in case of fixed installation
≥ 70 mm in case of flexible installation

1) The data for non-linearity (dLin), hysteresis (dhy) and temperature effect on C (TKC) are typical values. For OIML R60- or NTEP-approved load cells, the sum of these values is within the permissible cumulative error limits.

Mounting kits for load cell Pendeo® PR 6224B
Maximum capaci- ty of the load cell PR 6224B Mounting kit/accessories Material Description/ comments Mounting screws Height (mm)
25 t–75 t PR 6021/01N Electrogalvanised steel, chromated and sealed (RoHS-compliant) Mounting kit incl. Load disc and base component M12-8.8 190.5
PR 6021/03N Mounting kit incl. Load disc and base component with anti-rotation protection
PR 6021/05N Mounting kit incl. Load disc (turbo load disc) and base component
PR 6021/07N Mounting kit incl. Load disc (turbo load disc)
and base component with anti-rotation protection
PR 6021/00N Load disc and base component incl. ground strap / /
PR 6021/02N Load disc and base component with anti-rotation protection / /
PR 6021/04N Load disc (turbo load disc) and base component / /
Cable junction box PR 6024
Parameters PR 6024/68S
Number of load cells 1 to 8
Material 1.4404, AISI 316L
Protection class IP66/IP68/IP69
ATEX approval Zone 2/22
Service temperature range -30°C to +80°C
Service temperature range in explosive atmospheres -20 °C to +60 °C
Storage and transport -30°C to +80°C
Supply voltage 24 VDC
PR 6024/62S power supply unit
Parameters PR 6024/62S
Material 1.4301, AISI 304
Protection class IP66/IP68/IP69
ATEX approval Zone 2/22
Service temperature range -30°C to +80°C
Service temperature range in explosive atmos- pheres -20 °C to +50 °C
Storage and transport -30°C to +80°C
Supply voltage 100 to 240 VAC ±10%, 50/60 Hz
Power consumption Max. 35 VA
Output voltage 24 VDC
Supply and data cable PR 6124
Parameters PR 6124/xxD PR 6124/xxP
Cable type Data cable Supply cable
Cable diameter 5.8 mm 5.2 mm
Cable inductance A/C: 0.5 µH/km
A/A: 0.7 µH/km
/
Bending radius Fixed installation: 30 mm Repeated bending: 70 mm Fixed installation: 25 mm Repeated bending: 60 mm
Cable capacity A/C: <110 pF/m
A/A: <60 pF/m
/
Conductivity resistance ≤ 57 Ω/km /
Temperature range for operation and storage Operation: -30°C to +90 °C Storage: -40 °C to +90 °C Short term up to +125°C Operation: -30°C to +90 °C Storage: -40 °C to +90 °C Short term up to +125°C
Test voltage A/C: 800 V
A/A: 1,200 V
VDE 0472 part 509 test type B
/
Resistance to oil VDE 0472 part 803 VDE 0472 part 803
Resistance to flames EN 60332 1-2 EN 60332 1-2
Technical diagrams
Load cell Pendeo® Truck PR 6224B

All dimensions in mm

Mounting kits PR 6021

 

PR 6021/01N, ../03N

 

PR 6021/05N, ../07N

Cable junction box PR 6024

Cable junction box PR 6024/68S

PR 6024/62S power supply unit

All dimensions in mm

Ex approval
Scope of validity:
PR 6224B/PR 6024

Load cell Pendeo® Truck certificates
Zone Marking Certificate number For
2 II 3G Ex nA IIC T5 Gc Manufacturer’s declaration All PR 6224B/xx PR 6024/6x
22 II 3D Ex tc IIIC T90 °C Dc

Ordering information

Load cell Pendeo® Truck (OIML R60, accuracy class C3= 0.015%, C6= 0.008%)
Type Order number
PR 6224B/25t C3 940522423325
PR 6224B/25t C6 940522426325
PR 6224B/50t C3 940522423350
PR 6224B/50t C6 940522426350
PR 6224B/75t C3 940522423375
PR 6224B/75t C6 940522426375
Mounting kits
Type Order number
PR 6021/00N 940536021001
PR 6021/01N 940536021011
PR 6021/02N 940536021021
PR 6021/03N 940536021031
PR 6021/04N 940536021041
PR 6021/05N 940536021051
PR 6021/06N 940536021061
PR 6021/07N 940536021071
Cable junction box, power supply
Type Order number
PR 6024/68S 940536024684
PR 6024/62S 940536024624
Data and electrical supply cable
Type Order number
PR 6124/01D (1 m) 940536124013
PR 6124/01P (1 m) 940536124014
PR 6124/31D (30 m) 940536124313
PR 6124/ 31P (30 m) 940536124314
PR 6124/51D (50 m) 940536124513
PR 6124/51P (50 m) 940536124514
PR 6124/12D (100 m) 940536124123
PR 6124/12P (100 m) 940536124124
PR 6124/15D (150 m) 940536124153
PR 6124/15P (150 m) 940536124154
PR 6124/22P (200 m) 940536124224

 

Reviews