Description
Load cell PR 6241, converter Connexx® and mounting kits PR 6041/PR 6043/PR 6044 For the precise weighing of process vessels
Technical specifications
Load cell PR 6241
| Parameter | Description | Abbr. | D1 | C3 | C6 | Unit |
| Accuracy class | 0.04 | 0.015 | 0.008 | %Emax | ||
| Minimum dead load | Lowest limit of specified measuring range | Emin | 0 | 0 | 0 | %Emax |
| Maximum capacity | Highest limit of specified measuring range | Emax | See Ordering information table | kg | ||
| Safe load limit | Maximum load without irreversible damage | Elim | 150 | 150 | 150 | %Emax |
| Destructive load | Danger of mechanical destruction | Ed | > 300 | > 300 | > 300 | %Emax |
| Minimum load cell verification interval (OIML)
For NTEP, see separate table |
Minimum load cell verification interval, vmin = Emax/Y | Y | 5,000 | 14,000 | 20,000 | |
| Deadload output return | Factor for deadload output return after load (DR=1/2*Emax/Z) | Z | 1,000 | 3,000 | 8,000 | |
| Rated output | Relative output at maximum capacity | Cn | 2 | 2 | 2 | mV/V |
| Tolerance on rated output | Permissible deviation from rated output | dc | <0.25 | <0.07 | <0.07 | %Cn |
| Zero output signal | Load cell output signal under unloaded condition | Smin | 0±1.0 | 0±1.0 | 0±1.0 | %Cn |
| Reproducibility | Max. change in load cell output for repeated loading | eR | <0.01 | <0.005 | <0.005 | %Cn |
| Creep | Max. change of output signal at Emax for 30 min. | dcr | <0.03 | <0.015 | <0.008 | %Cn |
| Non-linearity1) | Max. deviation from best straight line through zero | dLin | <0.03 | <0.01 | <0.01 | %Cn |
| Hysteresis1) | Max. difference in LC output between loading and unloading | dhy | <0.04 | <0.015 | <0.008 | %Cn |
| Temperature effect on Smin | Max. change of Smin in BT | TKSmin | <0.028 | <0.01 | <0.007 | %Cn/10 K |
| Temperature effect on C1) | Max. change of C in BT | TKC | <0.03 | <0.01 | <0.005 | %Cn/10 K |
| Input impedance | Between supply terminals | RLC | 650 ± 6 | 650 ± 6 | 650 ± 6 | Ω |
| Output impedance | Between measuring terminals | RO | 610 ± 1 | 610 ± 0.5 | 610 ± 0.5 | Ω |
| Insulation impedance | Between measuring circuit and housing at 100 VDC | RIS | > 5,000 ×106 | > 5,000 ×106 | > 5,000 ×106 | Ω |
| Insulation voltage | Between circuit and housing (PR 6241/..E only) | 500 | 500 | 500 | V | |
| Recommended supply voltage | To hold the specified performance | Bu | 4 … 24 | 4 … 24 | 4 … 24 | V |
| Max. supply voltage | Permissible for continuous operation without damage | Umax | 28/(EX versions: 25) | V | ||
| Nominal ambient temp. range | To hold the specified performance | BT | -10 … +55 | -10 … +55 | -10 … +55 | °C |
| Usable ambient temp. range | Permissible for continuous operation without damage | BTu | -40 …+95 | -40 …+95 | -40 …+95 | °C |
| Storage temperature range | Without electrical and mechanical stress | BTi | -40 …+95 | -40 …+95 | -40 …+95 | °C |
| Permissible eccentricity | Permissible displacement from nominal load line | Sex | 5 | 5 | 5 | mm |
| Vibration resistance | Resistance against oscillations (IEC 68-2-6 Fc) | 20 g, 100 h, 10 …150 Hz | ||||
| Barometric pressure influence | Influence of barometric pressure on output | PKSmin | <0.005 | <0.0025 | <0.0025 | %Cn/kPa |
| Nominal deflection | Max. elastic deformation under maximum capacity | Snom | < 0.3 for Emax < 5 t/< 0.5 for Emax = 5 t | mm | ||
| Material (sensor) | Stainless steel 1.4542 | |||||
| Protection class | PR 6241: IP68*/IP69
Connexx®: IP65/IP68** |
|||||
| Cable | Length: 5 m
Diameter: 5 mm Cross section: 4 × 0.35 mm2 Material cable sheath: TPE |
|||||
| Bending radius | ≥ 25 mm at fixed installation
≥ 75 mm at flexible installation |
|||||
| Connexx® | ||||
| Nominal ambient temp. range | To hold the specified performance | BT | -10 … +40 | °C |
| Usable temperature range | Permissible for continuous operation without damage | BTu | -30 … +60 | °C |
| Storage temperature range | Without electrical and mechanical stress | BTi | -30 … +70 | °C |
* The load cell can be submerged in water at a depth of 1.5 m for 10,000 hours.
** The module can be submerged in water at a depth of 1.5 m for 100 hours.
1) The data for Non-linearity, hysteresis and TKC are typical values. For OIML R60 or NTEP approved load cells the sum of these values is within the permissible cumulative error
| NTEP classification PR 6241 | |||||||||||
| NTEP | NTEP minimum load cell verification interval, vmin | ||||||||||
| Maximum capacity | with OIML class | divisions nmax | 100 kg | 200 kg | 300 kg | 500 kg | 1 t | 2 t | 3 t | 5 t | Unit |
| Class III Multiple | D1 | 2,000 | 20 | 40 | 60 | 100 | 200 | 400 | 600 | 1,000 | g |
| Class III Multiple | C3 | 5,000 | — | 14.3 | 21 | 36 | 71 | 143 | 214 | 357 | g |
| Class III Multiple | C6 | 8,000 | — | 10 | 15 | 25 | 50 | 100 | 150 | — | g |
| Class IIIL Multiple | D1 | 5,000 | 6.7 | 13.3 | 20 | 33 | 67 | 133 | 200 | 333 | g |
| Class IIIL Multiple | C3 | 10,000 | — | 5 | 7.1 | 12 | 24 | 48 | 71 | 119 | g |
| Class IIIL Multiple | C6 | 10,000 | — | 3 | 5 | 8 | 17 | 33 | 50 | — | g |
| Mounting kits PR 6041/PR 6043/PR 6044 | |||||||||
| Maximum capaci- ty of load cell
PR 6241 |
Mounting kit/ accessories |
Material |
Description/ comments |
Mounting screws |
Installation height (mm) | Max. permissible horizontal force (kN) |
Horizontal dest- ructive force [KN] |
Max. permissible lift-off force [kN] |
Max. permissible vertical load with- out load cell |
| 100 kg–
500 kg |
PR 6041/04N |
Elastomeric bearing |
M12 |
53 |
/ |
/ |
/ |
/ |
|
|
100 kg–2 t |
PR 6041/30N | Electrogalvanised steel S235, passivated and sealed | Plate mounting kit | M8-5.8 |
92 |
/ | / | / | / |
| PR 6041/30S | Stainless steel 1.4301
(AISI 304) |
Plate mounting kit | M8-A2-70 | / | / | / | / | ||
| PR 6043/30N | Electrogalvanised steel S235, passivated and sealed | MiniFLEXLOCK | M8-8.8 | 6 | 20 | / | 2 t | ||
| PR 6043/30S |
Stainless steel 1.4301 (AISI 304) |
MiniFLEXLOCK | M8-A2-70 | 6 | 20 | / | 2 t | ||
| PR 6044/00S | Plate mounting kit | M8-A2-70 | / | / | 10 | 2 t | |||
| PR 6044/10S | MaxiFLEXLOCK | M8-A2-70 | 6 | 20 | 10 | 2 t | |||
| PR 6041/51S | Platform base | / | 44 | / | / | / | / | ||
| PR 6043/31S | Load disc kit | / | / | / | / | / | / | ||
|
3 t–5 t |
PR 6041/40N | Electrogalvanised steel S235, passivated and sealed | Plate mounting kit | M12-5.8 |
130 |
/ | / | / | / |
| PR 6041/40S | Stainless steel 1.4301
(AISI 304) |
Plate mounting kit | M12-A2-70 | / | / | / | / | ||
| PR 6043/40N | Electrogalvanised steel S235, passivated and sealed | MiniFLEXLOCK | M12-8.8 | 18 | 50 | / | 5 t | ||
| PR 6043/40S |
Stainless steel 1.4301 (AISI 304) |
MiniFLEXLOCK | M12-A2-70 | 18 | 50 | / | 5 t | ||
| PR 6044/01S | Plate mounting kit | M12-A2-70 | / | / | 20 | 5 t | |||
| PR 6044/11S | MaxiFLEXLOCK | M12-A2-70 | 18 | 50 | 20 | 5 t | |||
Converter Connexx®

Fitted with the converter Connexx®, the load cell PR 6241 offers a whole host of possibilities:
- The digital version guarantees fast signalling times for reliable dosing processes.
- Thanks to the use of field bus communication, the cable junction box is no longer needed.
- The standard interface CANopen ensures straightforward installation and calibration.
- CANopen allows for extra-long communication paths of up to 200 m.
- Weight values can also be generated individual- ly – per load cell – meaning that defective load cells can be identified more easily.
Technical diagrams
Compression S-type load cell PR 6241

| Model | A [mm] | B [mm] | C [mm] | D [mm] | E [mm] |
| PR 6241/12…52 | 60 | 65 | 50 | 23 | M12 |
| PR 6241/13…23 | 60 | 65 | 50 | 30 | M12 |
| PR 6241/33 | 90 | 95 | 64 | 30 | M20 × 1.5 |
| PR 6241/53 | 90 | 95 | 64 | 35 | M20 × 1.5 |
Converter Connexx®

Mounting kits PR 6041/PR 6043/PR 6044

Elastomeric bearing PR 6041/04N

Plate mounting kit PR 6041/30N+S

Plate mounting kit PR 6041/40N+S
Platform base PR 6041/51 |
MiniFLEXLOCK PR 6043/30N+S |
|
MiniFLEXLOCK PR 6043/4 |
Plate mounting kit PR 6044/00S |
Plate mounting kit PR 6044/01S |
|
|
|
MaxiFLEXLOCK PR 6044/11S |
Ex approval
Scope of validity:
PR 6241 (100 kg…5 t)
| Certificates for compression S-type load cell PR 6241 | |||
| Zone | Labelling | Certificate number | For |
| 0 and 1 | II 1G Ex ia IIC T6 Ga
Ex ia IIC T6 Ga |
BVS 16 ATEX E 005
IECEx BVS 16.0005 |
PR 6241/..E only |
| 20 and 21 | II 1D Ex ta IIIC T160 °C Da Ex ta IIIC T160°C Da | TÜV 03 ATEX 2301X IECEx TUN 17.0025X | all PR 6241 without /..E |
| 2 | II 3G Ex nA IIC T6 Gc | Manufacturer’s declaration | all PR 6241 without /..E |
| 22 | II 3D Ex tc IIIC T85 °C Dc | Manufacturer’s declaration | all PR 6241 without /..E |
| FMus | IS CL I, II, III, DIV 1, GP A, B, C, D, E, F, G Entity – 4012 101 5688
NI CL I, II, III, DIV 2, GP A, B, C, D, E, F, G NIFW – 4012 101 5688 T4A Ta= -30 °C to 70 °C; T5 Ta= -30 °C to 55 °C |
FM17USO276 | all PR 6241 without /..E |
| FMca | IS CL I, II, III, DIV 1, GP A, B, C, D, E, F, G Entity – 4012 101 5688
NI CL I, II, III, DIV 2, GP A, B, C, D, E, F, G NIFW – 4012 101 5688 T4A Ta= -30 °C to 70 °C; T5 Ta= -30 °C to 55 °C |
FM17CA0138 | all PR 6241 without /..E |
Ordering information
| Compression S-type load cells OIML R60, accuracy class D1 = 0.04% | ||
| Type | Maximum capacity | Order number |
| PR 6241/12D1 | 100 kg | 940526241121 |
| PR 6241/22D1 | 200 kg | 940526241221 |
| PR 6241/32D1 | 300 kg | 940526241321 |
| PR 6241/52D1 | 500 kg | 940526241521 |
| PR 6241/13D1 | 1 t | 940526241131 |
| PR 6241/23D1 | 2 t | 940526241231 |
| PR 6241/33D1 | 3 t | 940526241331 |
| PR 6241/53D1 | 5 t | 940526241531 |
| Compression S-type load cells OIML R60, accuracy class D1 = 0.04%, ex-version | ||
| Type | Maximum capacity | Order number |
| PR 6241/12D1E | 100 kg | 940566241121 |
| PR 6241/22D1E | 200 kg | 940566241221 |
| PR 6241/32D1E | 300 kg | 940566241321 |
| PR 6241/52D1E | 500 kg | 940566241521 |
| PR 6241/13D1E | 1 t | 940566241131 |
| PR 6241/23D1E | 2 t | 940566241231 |
| PR 6241/33D1E | 3 t | 940566241331 |
| PR 6241/53D1E | 5 t | 940566241531 |
| Precision compression S-type load cells OIML R60, accuracy class C3 = 0.015% | ||
| Type | Maximum capacity | Order number |
| PR 6241/22C3 | 200 kg | 940526241227 |
| PR 6241/32C3 | 300 kg | 940526241327 |
| PR 6241/52C3 | 500 kg | 940526241527 |
| PR 6241/13C3 | 1 t | 940526241137 |
| PR 6241/23C3 | 2 t | 940526241327 |
| PR 6241/33C3 | 3 t | 940526241337 |
| PR 6241/53C3 | 5 t | 940526241537 |
| Precision compression S-type load cells OIML R60, accuracy class C3 = 0.015%, ex-version | ||
| Type | Maximum capacity | Order number |
| PR 6241/22C3E | 200 kg | 940566241227 |
| PR 6241/32C3E | 300 kg | 940566241327 |
| PR 6241/52C3E | 500 kg | 940566241527 |
| PR 6241/13C3E | 1 t | 940566241137 |
| PR 6241/23C3E | 2 t | 940566241327 |
| PR 6241/33C3E | 3 t | 940566241337 |
| PR 6241/53C3E | 5 t | 940566241537 |
| Precision compression S-type load cells OIML R60, accuracy class C6 = 0.008% | ||
| Type | Maximum capacity | Order number |
| PR 6241/22C6 | 200 kg | 940526241228 |
| PR 6241/32C6 | 300 kg | 940526241328 |
| PR 6241/52C6 | 500 kg | 940526241528 |
| PR 6241/13C6 | 1 t | 940526241138 |
| PR 6241/23C6 | 2 t | 940526241238 |
| PR 6241/33C6 | 3 t | 940526241338 |
| Precision compression S-type load cells OIML R60, accuracy class C6 = 0.008%, ex-version | ||
| Type | Maximum capacity | Order number |
| PR 6241/22C6E | 200 kg | 940566241228 |
| PR 6241/32C6E | 300 kg | 940566241328 |
| PR 6241/52C6E | 500 kg | 940566241528 |
| PR 6241/13C6E | 1 t | 940566241138 |
| PR 6241/23C6E | 2 t | 940566241238 |
| PR 6241/33C6E | 3 t | 940566241338 |
| Precision compression S-type load cells OIML R60, converter Connexx® | ||
| Type | Description | Order number |
| PR 6241/DIGITAL KIT | The converter Connexx® can only be ordered with the above-mentioned load cells from the PR 6241 series. When ordering, both order numbers need to be given. | 940514100000 |
Additional information:
The converters Connexx® can be used with the Indicator X3.
To do this, the indicator X3 must be equipped with a CANopen interface card PR 5510/05 (940535510051).
| Precision compression S-type load cells OIML R60, converter Connexx® – application sets | ||
| Type | Description | Order number |
| PR 6154/03 | Application set for 3 load cells.
Includes: 2 × PR 6155/05, 1 × PR 6152/25, 1 × PR 6153/99 |
940536154031 |
| PR 6154/04 | Application set for 4 load cells.
Includes: 3 × PR 6155/05, 1 × PR 6152/25, 1 × PR 6153/99 |
940536154041 |
| Precision compression S-type load cells OIML R60, converter Connexx® – load cell accessories | ||
| Type | Description | Order number |
| PR 6152/10 | Connection cable between Connexx® and X3 (10 m) | 940536152101 |
| PR 6152/25 | Connection cable between Connexx® and X3 (25 m) | 940536152251 |
| PR 6152/40 | Connection cable between Connexx® and X3 (40 m) | 940536152401 |
| PR 6153/98 | Divided cable gland | 940536153981 |
| PR 6153/99 | Terminal resistor for Connexx®, M12 | 940536153991 |
| PR 6155/05 | Connection cable between Connexx® and Connexx® (5 m) | 940536155051 |
| PR 6155/10 | Connection cable between Connexx® and Connexx® (10 m) | 940536155101 |
|
Mounting kits PR 6041 without constrainer |
|
| Type | Order number |
| PR 6041/04N | 940536041041 |
| PR 6041/30N | 940536041301 |
| PR 6041/30S | 940536041302 |
| PR 6041/40N | 940536041401 |
| PR 6041/40S | 940536041402 |
| PR 6041/51S | 940536041512 |
| Mounting kits PR 6043 –
MiniFLEXLOCK with integrated constrainer |
|
| Type | Order number |
| PR 6043/30N | 940536043301 |
| PR 6043/30S | 940536043302 |
| PR 6043/40N | 940536043401 |
| PR 6043/40S | 940536043402 |
| Mounting kits PR 6044 – MaxiFLEXLOCK with additional functions | |
| Type | Order number |
| PR 6044/00S | 940536044002 |
| PR 6044/10S | 940536044102 |
| PR 6044/01S | 940536044012 |
| PR 6044/11S | 940536044112 |
|
Mounting kits PR 6043 – load discs |
|
| Type | Order number |
| PR 6043/31S | 940536043312 |


0N+S
MaxiFLEXLOCK PR 6044/10S
Reviews