Minebea Intec / Single Point load cell LC aluminium

Reliable weighing through accurate
measurement results
Three different models for easy
integration
Versatile optional weighing electronics
Design-in support from specialists

Category:
Brand:

Description

Single Point load cell LC aluminium
Accurate measurement results for scale production

Ideal for integration in bench scales, counting scales and checkweighers: with the LC made from aluminium Single Point load cells, you can rely on the tried-and-tested quality of a leading manufacturer of industrial weighing technology. Suitable for load ranges of 5 kg to 750 kg and a platform size of up to 800 mm × 800 mm.
Verifiable load cells for a variety of industrial applications

  • The load cells developed in Germany guarantee accurate weighing results.
    All load cells are verifiable according to OIML and NTEP.
  • Three different models cover a wide range of load levels – from 5 kg up to 750 kg.
  • A comprehensive optional portfolio of transmitters, indicators and controllers ensures reliable continu- ous processing of the measurement signals as desired.
  • Comprehensive expertise in scale production ensures high-quality advice for individual projects.

Technical specifications

Parameters Description Abbr. PR 40 C3MR PR 43 C3MR PR 47 C3MR Unit
Accuracy class     0.02 %Emax
Minimum dead load Lowest limit of specified measuring range Emin 0 %Emax
Maximum capacity Highest limit of specified measuring range Emax 5 – 50 6 – 200 100 – 750 kg
Maximum usable load Upper limit for measurements Elim 150 %Emax
Destructive load Danger of mechanical destruction Ed 300 %Emax
Minimum LC verification Minimum load cell verification interval, vmin = Emax/Y Y 15,000  
Deadload output return Factor for deadload output return after load (DR=1/2*Emax/Z) Z 3,000  
Rated output Relative output at maximum capacity Cn 2 mV/V
Tolerance on rated output Permissible deviation from rated output dc < 10 %Cn
Zero output signal Load cell output signal under unloaded condition Smin 0 ± 5 %Cn
Repeatability error Max. change in load cell output for repeated loading eR < 0.0100 %Cn
Creep Max. change of output signal at Emax during 30 min. dcr < 0.0166 %Cn
Non-linearity1) Deviation from best straight line through zero dLin <0.0166 %Cn
Hysteresis1) Max. difference in LC output between loading and unloading dhy <0.0166 %Cn
Temperature effect (TK) on Smin Max. change related to Cn of Smin per 10K in BT TKSmin < 0.0093 %Cn /10K
Temperature effect (TK) on parameter1) Max. change related to Cn of C per 10K in BT TKC < 0.0117 %Cn /10K
Corner load error     0.0233 %Cn
Input impedance Between supply terminals RLC 380 ± 38 Ω
Output impedance Between measurement terminals RO 350 ± 25 Ω
Insulation impedance Between measuring circuit and housing at 100 VDC RIS > 5,000 × 106 Ω
Nominal supply voltage range To hold the specified performance Bu ≤12 V
Max. supply voltage Continuous operation without damage Umax 15 V
Nominal ambient temp. range To hold the specified performance BT -10 to +40 °C
Usable ambient temp. range Continuous operation without damage BTU -20 to +65 °C
Storage temperature range Without electrical and mechanical stress BTi -25 to +70 °C
Barometric pressure influence Influence of barometric pressure on output   < 0.007 < 0.007 < 0.007 %Cn /kPa
Nominal deflection Max. elastic deformation under maximum capacity Snom < 0.55 < 0.5 mm
Cable length     0.5 3 m
Material Aluminium        
 
 
 
Max. platform size
 
 
In compliance with the technical data according to OIML R76
   
 
 
350 × 350
450 × 450
for Emax = 15 to 30 kg
600 × 600
for Emax =
50 to 100 kg
 
 
 
800 × 800
 
 
 
mm × mm
IP protection class According to EN 60529: IP66 + IP67

1) The data for non-linearity (dLin), hysteresis (dhy) and temperature effect on C (TKC) are typical values. For OIML R60 or NTEP approved load cells, the sum of these values is within the permissible cumulative error limits.

Accuracy classes and minimum verification interval, vmin – PR 40
Capacity Maximum number of verification intervals, nmax 5 kg 7,5 kg 10 kg 15 kg 20 kg 30 kg 40 kg 50 kg  
C3MR 3000 0,34 0,50 0,67 1,00 1,34 2,00 2,67 3,34 g
NTEP III 5000 Single 5000 0,34 0,50 0,67 1,00 1,34 2,00 2,67 3,34 g
Accuracy classes and minimum verification interval, vmin – PR 43
Capacity Maximum number of verification intervals, nmax 6 kg 10 kg 15 kg 20 kg 30 kg 50 kg 75 kg 100 kg 200 kg  
C3MR 3000 0,40 0,67 1,00 1,34 2,00 3,34 5,00 6,67 13,34 g
NTEP III 5000 Single 5000 0,40 0,67 1,00 1,34 2,00 3,34 5,00 6,67 13,34 g
Accuracy classes and minimum verification interval, vmin – PR 47
Capacity Maximum number of verification intervals, nmax 100 kg 150 kg 200 kg 250 kg 300 kg 500 kg 750 kg  
C3MR 3000 6,67 10,00 13,34 16,67 20,00 33,34 50,00 g
NTEP III 5000 Single 5000 6,67 10,00 13,34 16,67 20,00 33,34 50,00 g


Technical diagrams
Single Point load cell LC – PR 40

Single Point load cell LC – PR 43

Single Point load cell LC – PR 47

Ex approval
Scope of validity:
Single Point load cell LC aluminium

Certificates for Single Point load cell LC aluminium
Zone Marking Certificate number For
0 and 1 II 1G Ex ia IIC T6/T4 Ga  
 
BVS 21 ATEX E 023 X IECEx BVS 21.0024X
 
PR 4x/xx E only
20 II 1D Ex ia IIIC T200165°C Da
2 II 3G Ex ec IIC T6/T4 Gc  
All PR 4x without E

Ordering information

Single Point Wägezelle LC – PR 40
Typ Order number
PR 40/5 kg C3MR 9409 240 07005
PR 40/7,5 kg C3MR 9409 240 07007
PR 40/10 kg C3MR 9409 240 07010
PR 40/15 kg C3MR 9409 240 07015
PR 40/20 kg C3MR 9409 240 07020
PR 40/30 kg C3MR 9409 240 07030
PR 40/40 kg C3MR 9409 240 07040
PR 40/50 kg C3MR 9409 240 07050
Single Point load cell LC – PR 43
Typ Order number
PR 43/6 kg C3MR 9409 243 07006
PR 43/10 kg C3MR 9409 243 07010
PR 43/15 kg C3MR 9409 243 07015
PR 43/20 kg C3MR 9409 243 07020
PR 43/30 kg C3MR 9409 243 07030
PR 43/50 kg C3MR 9409 243 07050
PR 43/75 kg C3MR 9409 243 07075
PR 43/100 kg C3MR 9409 2430 7110
PR 43/200 kg C3MR 9409 2430 7120
Other accuracy classes and EX
Typ Order number
PR 4x/xx kg C6 9409 24x 06xxx
PR 4x/xx kg III 5000 S 9409 24x 0Cxxx
PR 4x/xx kg C3MRE 9409 64x 07xxx
PR 4x/xx kg C6E 9409 64x 06xxx
Single Point load cell LC – PR 47
Type Order number
PR 47/100 kg C3MR 9409 247 07110
PR 47/150 kg C3MR 9409 247 07115
PR 47/200 kg C3MR 9409 247 07120
PR 47/250 kg C3MR 9409 247 07125
PR 47/300 kg C3MR 9409 247 07130
PR 47/500 kg C3MR 9409 247 07150
PR 47/750 kg C3MR 9409 247 07175

 

Reviews