Description
F327 Canister Loadcell
The F327 is a robust canister loadcell that is ideally suited to compression force measurement applications in harsh conditions.
The loadcell is deliberately over engineered to achieve a low contact surface pressure under high loading.
Smaller column type loadcells, such as the F218, are available and we can cover the F327 load ranges with smaller designs. Please consult our engineering department.
The loadcell is deliberately over engineered to achieve a low contact surface pressure under high loading.
Smaller column type loadcells, such as the F218, are available and we can cover the F327 load ranges with smaller designs. Please consult our engineering department.
Specification
| Parameter | Value | Unit |
|---|---|---|
| Non-linearity – Terminal | ±0.05 (10 – 50kN) / ±0.1 (100 – 1000kN) / ±0.4 (2000kN) | % RL |
| Hysteresis | ±0.05 (10 – 50kN) / ±0.4 (100 – 1000kN) / ±0.4 (2000kN) | % RL |
| Creep – 20 minutes | ±0.05 (10 – 50kN) / ±0.05 (100 – 1000kN) / ±0.05 (2000kN) | % AL |
| Repeatability (excluding rotational effects)* | ±0.02 (10 – 50kN) / ±0.03 (100 – 1000kN) / ±0.03 (2000kN) | % RL |
| Rated output – Nominal | 1.2 (10 – 50kN) / 1.2 (100 – 1000kN) / 1.2 (2000kN) | mV/V |
| Rated output – Rationalised | 1.0 (10 – 50kN) / 1.0 (100 – 1000kN) / 1.0 (2000kN) | mV/V |
| Rationalisation tolerance | ±0.5 (10 – 50kN) / ±0.5 (100 – 1000kN) / ±0.5 (2000kN) | % RL |
| Zero load output | ±4 (10 – 50kN) / ±4 (100 – 1000kN) / ±4 (2000kN) | % RL |
| Temperature effect on rated output per °C | ±0.005 (10 – 50kN) / ±0.005 (100 – 1000kN) / ±0.005 (2000kN) | % AL |
| Temperature effect on zero load output per °C | ±0.01 (10 – 50kN) / ±0.01 (100 – 1000kN) / ±0.01 (2000kN) | % RL |
| Temperature range – Compensated | -10 to +50 | °C |
| Temperature range – Safe | -10 to +80 | °C |
| Excitation voltage – Recommended | 10 (10 – 50kN) / 10 (100 – 1000kN) / 10 (2000kN) | V |
| Excitation voltage – Maximum | 20 (10 – 50kN) / 20 (100 – 1000kN) / 20 (2000kN) | V |
| Bridge resistance | 700 (10 – 50kN) / 700 (100 – 1000kN) / 700 (2000kN) | Ω |
| Insulation resistance – Minimum at 50Vdc | 500 (10 – 50kN) / 500 (100 – 1000kN) / 500 (2000kN) | MΩ |
| Overload – Safe | 50 (10 – 50kN) / 50 (100 – 1000kN) / 50 (2000kN) | % RL |
| Overload – Ultimate | 200 (10 – 50kN) / 200 (100 – 1000kN) / 200 (2000kN) | % RL |
| Sealing | IP67 | |
| Weight – Nominal (excluding cable) | 1.6 (10 – 50kN) / 8 to 24.1 (100 – 1000kN) / 28.3 (2000kN) | kg |
Order Codes
| Code | Description |
|---|---|
| F327CFS0K0 | Compression, IP67, unrationalised |
| F327CFS0KN | Compression, IP67, rationalised |
| Change the F to a P for the connector version. |
Structural Stiffness
| Range (kN) | Stiffness (N/m) |
|---|---|
| 10 | 2.2 x 108 |
| 20 | 4.3 x 108 |
| 50 | 1.1 x 109 |
| 100 | 1.6 x 109 |
| 200 | 3.2 x 109 |
| 500 | 8.1 x 109 |
| 1000 | 8.3 x 109 |
| 2000 | 8.7 x 109 |
Notes
- AL = Applied load.
- RL = Rated load.
- Temperature coefficients apply over the compensated range.
- The load must be applied directly through the central loading axis.
Connections
The loadcell is fitted with 2 metres of PVC insulated 4 core screened cable type 16-2-4C or a 4 pin Binder 723 series chassis plug.
Excitation + = Red or pin 1, Excitation – = Blue or pin 2, Signal + = Yellow or pin 3, Signal – = Green or pin 4, Screen = Orange.
The screen is not connected to the loadcell body.