Description
FN3050 Load Cell Tension and Compression
The rugged FN3050 load cell is highly suited for process industryand test bench applications. Dimensions are identical instandard ranges from 0-100 N to 0-20000 N so during testing thesensor can be interchanged for another of a different rangewithout mechanical modifications. The sensor design minimizestransverse effects. For high-level output, a model with integratedamplifier is available as are numerous other options.With a long-standing experience as a designer andmanufacturer of sensors, TE CONNECTIVITY often works withcustomers to design or customize sensors for specific uses andtesting environments.To meet your needs, we also offer extensive turnkeysystems. The matched components (sensor, power, amplifierand digital display) are formatted, calibrated and ready forimmediate use.On request, Instruction documents can be provided toease the selection and use of our sensors and provide helpfultips.
FEATURES
– Same housing for all ranges
– Mechanical stops in option
– Optional: Tension Pull Plate, Load Button
– Integrated amplifier optional
APPLICATIONS
– Process control equipment
– Regulation load cell
– Robotics and effectors
– Laboratory and Research
– Dedicated to low and medium
quantity volume
CHARACTERISTICS (typical values at temperature 23°C)
| Ranges (FS) (N) | 100 | 200 | 500 | 1k | 2k | 5k | 10k | 20k |
| Ranges (lbf) | 22.48 | 44.96 | 112.4 | 224.8 | 449.6 | 1124 | 2248 | 4496 |
| Material | Aluminium | Stainless Steel | Aluminium | Stainless Steel | ||||
| Stiffness (N/m) | 1.2E+06 | 2.7E+06 | 9.9E+06 | 1.7E+07 | 3.9E+07 | 2.3E+08 | 5.4E+08 | 8.7E+08 |
| Stiffness (lbf/ft) | 8.4E+04 | 1.8E+05 | 6.8E+05 | 1.2E+06 | 2.7E+06 | 1.6E+07 | 3.7E+07 | 5.9E+07 |
| Linearity & hyteresis | < ±0.3% FS | – | ||||||
| Linearity | – | < ±0.1% FS | ||||||
| Hyteresis | – | < ±0.1% FS | ||||||
| Version | Standard | A1 | A2 |
| Power supply | 10Vdc | 10Vdc à 30Vdc | ±12Vdc à ±18Vdc |
| Sensitivity (FSO) | ±15mV | ±2Vdc ±0.2V | ±5Vdc ±0.25V |
| Offset | <±1 mV | 2.5Vdc ±0.2V | 0V ±0.25V |
| Input Impedance / Consumption | 700 ohms | <30mA | |
| Output Impedance | 700 ohms | 1000 ohms | |
| Overrange Without Damage | 1.5x FS | ||
| Overrange Without Destruction | 3x FS | ||
| Operating Temperature Range (OTR) | -20°C to +80°C (-4°F to 176°F) | ||
| Compensated Temperature Range (CTR) | 0°C to +60°C (32°F to 140°F) | ||
| Thermal Zero Shift in CTR | < 0.5% FS/50°C | ||
| Thermal Sensitivity Shift in CTR | < 1%/50°C | ||
| Insulation | > 1000 Mohms | ||
| Protection Index | IP50 | ||
Notes
- Signal goes positive in tension with standard wiring Other signal output on request
- Electrical Termination: Connector output including mate
- Body in stainless steel or aluminium alloy depending on S.
- Output impedance < 100Ω on request
- CE conformance according to EN 61010-1, EN 50081-1, EN 50082-1
DIMENSIONS & WIRING SCHEMATIC (IN METRIC AND IMPERIAL)
OPTIONS
| B2 | Mechanical stops (compression only, models ≤2000 N) Overrange Without Damage 10x FS |
| Z04 | CTR -40°C to +90°C (-40°F to 194°F) (OTR -40°C to +90°C (-40°F to 194°F)) |
| Z35 | CTR +20°C to +120°C (68°F to 248°F) (OTR -20°C to +120°C (-4°F to 248°F)) |
| Z36 | CTR +20 to +150°C (68°F to 302°F) (OTR -20°C to +150°C(-4°F to 302°F)) – not available with A1/A2 |
ORDERING INFO



Reviews