Description
FN9620 HARSH ENVIRONMENT S-BEAM LOAD CELL
The FN9620 is a S-Beam load cell with ranges from 500N to 10kN, designed to operate in hostile environments from -40 to 90°C with IP68 ingress protection.
It provides high stiffness for high cycle use, low off-axis load sensitivity and high level of accuracy.
To ease its use for Process Control Automation equipment, the sensor’s sensitivity (in mV/V) is calibrated with
2% tolerance. On request, Instruction documents can be provided to ease the selection and use of our sensors and provide helpful tips.
FEATURES APPLICATIONS
– High tensile strength Stainless Steel
– Metric or Imperial thread
– Surcharge sans destruction 300%
– Safe over load 300%
– 3 meters Integral cable
– IP68-1m water column
– Structure Testing
– Test Benches
– Process Control & Automation
– Mechanical resistance of materials
– Laboratory and Research
PERFORMANCE SPECIFICATIONS (typical values at temperature 23°C)
| Specification | Unit | 0.5 kN | 1 kN | 2 kN | 5 kN | 10 kN |
|---|---|---|---|---|---|---|
| Range (FS) | kN | 0.5 | 1 | 2 | 5 | 10 |
| Over Range | % FS | 150 | 150 | 150 | 150 | 150 |
| Sensitivity (FSO)* | mV/V | 1 ±2% | 1 ±2% | 2 ±2% | 2 ±2% | 2 ±2% |
| Power Supply (regulated) | Vdc | 10 | 10 | 10 | 10 | 10 |
| Power Supply (min/max)** | Vdc | 1 to 10 | 1 to 10 | 1 to 10 | 1 to 10 | 1 to 10 |
| Bridge Resistance | Ω | 350 | 350 | 350 | 350 | 350 |
| Bridge Resistance (min/max) | Ω | 340 / 500 | 340 / 500 | 340 / 500 | 340 / 500 | 340 / 500 |
| Zero Offset | ±% FS | 2 | 2 | 2 | 2 | 2 |
| Insulation (under 50 Vdc) | MΩ | >5000 | >5000 | >5000 | >5000 | >5000 |
| Linearity | ±% FS | 0.05 | 0.05 | 0.05 | 0.05 | 0.05 |
| Hysteresis | ±% FS | 0.03 | 0.03 | 0.03 | 0.03 | 0.03 |
| Repeatability | ±% | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 |
| Symmetry | ±% | 0.25 | 0.25 | 0.25 | 0.25 | 0.25 |
| Creep (20 min) | % | 0.025 | 0.025 | 0.025 | 0.025 | 0.025 |
| Side Load Sensitivity** | % | 1 | 1 | 1 | 1 | 1 |
| Eccentric Load Sensitivity | %/mm | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 |
| Safe Overload | % | 300 | 300 | 300 | 300 | 300 |
| Deflection | mm | 0.033 | 0.065 | 0.075 | 0.08 | 0.13 |
| Stiffness | N/m | 1.5×10⁷ | 1.5×10⁷ | 2.6×10⁷ | 6.2×10⁷ | 7.6×10⁷ |
| Natural Frequency | kHz | 1 | 1 | 1.25 | 1.95 | 2.15 |
| Operating Temperature Range (OTR) | °C | -40 to +90 | -40 to +90 | -40 to +90 | -40 to +90 | -40 to +90 |
| Compensated Temperature Range (CTR) | °C | -10 to +45 | -10 to +45 | -10 to +45 | -10 to +45 | -10 to +45 |
| Thermal Zero Shift (CTR) | ±% FS/°C | 0.008 | 0.008 | 0.004 | 0.004 | 0.004 |
| Thermal Sensitivity Shift (CTR) | ±%/°C | 0.01 | 0.01 | 0.005 | 0.005 | 0.005 |
| Ingress Protection | IP68 – 1 m water column – 100 h | IP68 – 1 m water column – 100 h | IP68 – 1 m water column – 100 h | IP68 – 1 m water column – 100 h | IP68 – 1 m water column – 100 h | |
| Side Load Limit | % FS | 100 | 100 | 100 | 100 | 100 |
| Bending Moment Limit | N·m | 15 | 30 | 60 | 150 | 300 |
| Weight (without cable) | kg | 0.45 | 0.45 | 0.45 | 0.45 | 0.45 |
| Cable Length*** | m | 3 | 3 | 3 | 3 | 3 |
| Material | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
* Signal goes positive in traction with standard wiring configuration
** Load = 10% range
*** 4 conductors shielded Ø5 -neoprene jacket
DIMENSIONS (in mm) & WIRING



Reviews