Model 240 Fluid-Damped Single-Point Load Cell
FEATURES
• Capacities 2–50 kg
• Painted steel construction
• OIML R60 and NTEP approved
• IP66 protection
• Available with metric and UNC threads
• Optional
-Stainless steel construction
APPLICATIONS
• Multi-head illing machines
• Check weighing
• Grading machines
• Liquid illing
• Dynamic weighing

| SPECIFICATIONS | ||||
| PARAMETER | VALUE | UNIT | ||
| Rated capacity—R.C. (Emax) | 2, 3, 5, 7, 10, 15, 20, 30, 50** | kg | ||
| OIML accuracy class | NTEP | Non-Approved | C3* | |
| Maximum no. of intervals (n) | 5000 | 1000 | 3000 | |
| Y = Emax/Vmin | 12000 | 1750 | 9000 | Maximum available |
| Rated output—R.O. | 2.0 | mV/V | ||
| Rated output tolerance | 0.2 | ±mV/V | ||
| Zero balance | 0.1 | ±mV/V | ||
| Zero return, 30 min. | 0.033 | 0.050 | 0.015 | ±% of applied load |
| Total error | 0.050 | 0.025 | 0.015 | ±% of rated output |
| Temperature effect on zero | 0.0026 | NA | 0.0026 | ±% of rated output/°C |
| Temperature effect on output | 0.0010 | NA | 0.0010 | ±% of rated output/°C |
| Temperature range, compensated | –10 to +40 | °C | ||
| Temperature range, safe | –30 to +70 | °C | ||
| Maximum safe central overload | 150 | % of R.C. | ||
| Ultimate central overload | 300 | % of R.C. | ||
| Excitation, recommended | 10 | VDC or VAC RMS | ||
| Excitation, maximum | 15 | VDC or VAC RMS | ||
| Input impedance | 415±15 | Ω | ||
| Output impedance | 350±3 | Ω | ||
| Insulation resistance | >1000 | MΩ | ||
| Cable length | To suit | m | ||
| Cable type | 6-wire, braided, polyurethane, silicone gel impregnation | Standard | ||
| Construction | Painted mild steel*** | |||
| Environmental protection | IP66 | |||
* 50% utilization
** 2 and 3 kg are not approved by NTEP or OIML
*** Stainless steel available
All speciications subject to change without notice.