Revere Transducers / 9102 Single-Ended Beam Load Cell

The load cell model 9102 is a stainless steel, bending beam. The 9102 is available in the capacities 200-2500 lbs. The load cell is suitable for small and medium platform scales, overhead track scales and process weighing. Fully welded construction and water block cable-entry ensure that this product can be used successfully in harsh environments found in the food, chemical and allied industries. Hermetically sealed IP66 and IP68. Certified to OIML R-60, 5000d and NTEP class III, 5000d. The load cell is available in ATEX and FM approved versions for use in potentially hazardous areas.

Brand: ,

Description

9102 Single-Ended Beam Load Cell

FEATURES
• Capacities: 200–2500 lbs.
• Low profile, stainless steel construction
• Hermetically sealed, IP66 and IP68
• Certified to OIML R-60, 5000d and NTEP class III, 5000
divisions
• Current calibration output (SC version) ensures easy
and accurate parallel connection of multiple load cells
• Interchangeable with existing Model 5102
• Optional
 ATEX and FM certified versions are available for use
in potentially explosive atmospheres

APPLICATIONS
• Platform scales
• Belt scales
• Silo/hopper weighing
• Overhead track scales

SPECIFICATIONS
PARAMETER VALUE UNIT
Standard capacities (=Emax) 200, 500, 1000, 2500 lbs.
Accuracy class according to OIML R-60 / NTEP III Non- Approved C3 C5  
Max. no. of verification intervals (n) 5000   3000 5000  
Minimum verification interval (Vmin)   Emax/15000 Emax/15000  
Rated output (=S) 2 mV/V
Rated output tolerance 0.02 ±mV/V
Zero balance 1.0 ±% FSO
Combined error 0.0200 0.0500 0.0200 0.0100 ±% FSO
Non-repeatability 0.0100 0.0200 0.0100 0.0070 ±% FSO
Minimum dead load output return 0.0250 0.0500 0.0167 0.0100 ±% applied load
Creep error (30 minutes)   0.0600 0.0245 0.0147 ±% applied load
Creep error (20-30 minutes)   0.0200 0.0053 0.0032 ±% applied load
Temp. effect on min. dead load output (0.0008) 0.0250 0.0047 0.0047 ±% FSO/5°C (/°F)
Temp. effect on sensitivity (0.0010) 0.0250 0.0055 0.0035 ±% applied load/5°C (/°F)
Minimum dead load 0 % Emax
Maximum safe overload 150 % Emax
Ultimate overload 300 % Emax
Maximum safe side load 100 (50 for 200 lbs.) % Emax
Deflection at Emax 0.2/ 0.2/ 0.8/ 0.8 mm
Excitation voltage 5 to 12 V
Maximum excitation voltage 15 V
Input resistance 350±3.5 0
Output resistance 350±3.5 0
Insulation resistance >5000 M0
Compensated temperature range –10 to +40 °C
Operating temperature range –40 to +80 °C
Storage temperature range –40 to +90 °C
Element material Stainless steel 1.4542  
Sealing (DIN 40.050 / EN 60.529) IP66 and IP68  
SC-Version Standard  
Recommended torque on fixation bolts 80 (70 for 200 lbs.) N*m

FSO—Full Scale Output
SC-version: The rated output and the output resistance are balanced in such a way that the output current is calibrated to within 0.05%
of a reference value. This allows easy parallel connection of the load cells.
Correct mounting of the load cells is essential to ensure optimum performance. Further information is available on request.
All specifications are subject to change without notice.

Reviews

There are no reviews yet.

Be the first to review “Revere Transducers / 9102 Single-Ended Beam Load Cell”