BLH NOBEL / KIS-9 Load Cell/Weigh Module

The KIS-9 load cell has several features that clearly distinguish it from other load cells. It is easy to install and extremely accurate, even when subjected to vibration forces and severe environmental conditions. Due to the rugged cantilever design and position of the floating yoke it is not affected by side forces up to 100%. This makes it non sensitive to thermal expansions, vibrations and disturbing side force. All KIS load cells can be ATEX/IECEx certified for use in explosive atmospheres.

브랜드:

설명

KIS-9 Load Cell/Weigh Module

Features
Capacity range: 5, 10, 20, 50, and 100 kN (1.12K, 2.25K, 4.5K, 11.2K, and 22.5K lb)
Simple installation
Moveable load point
Withstands very high lateral forces
Accurate and rugged
ATEX/IEXEx certified for hazardous locations
Application: Process Weighing & Batching,Hazardous Areas
Certificates: ATEX,IECEx
Combined Error: 0.06-0.1 %
Environment Protection Class: IP67,IP66,IP65,IP54,IP20
Industry: Chemical,Pharmaceutical,Food & Beverage
Material: Stainless Steel
Max Capacity: k lb: 0-25
Max Capacity: kN: 0-100
Max Capacity: ton: 0-10
Product Type: Weigh Modules & Load Cells

OUTLINE DIMENSIONS

RANGE kN L1 L2 L3 L4 L5 L6 ØA ØB
5–10–20 27 72 41 154 9 19 14 11
50 38 80 48 185 14 29 18 18
100 48 122 25 220 17 48 22 22
RANGE kN B1 B2 B3 B4 B5 H1 H2 H3 H4 H5 M
5–10–20 96 62 80 56 30 80 67 19 37 20.5 M10
50 128 88 128 88 48 115 93 33 48 28 M16
100 160 120 160 120 62 130 108 38 53 33 M20

Weigh Module

INSTALLATION EXAMPLES

Specifications

Parameter Value
PERFORMANCE
Rated load (RL) 5, 10, 20, 50, 100 kN
Combined error (terminal) ±0.1% RO
Repeatability 0.02% RO
Safe load 150% RL (1)
Ultimate load 200% RL (1)
Ultimate sideload 100% RL (1)
Creep at RL after 30 minutes ±0.03% RL
Rated output (RO) 1.020 mV/V
Tolerance of RO ±0.25% RO
Zero balance ±2% RO
Tolerance of shunt calibration values ±0.25% of value (2)
TEMPERATURE
Temperature range –40 to +80 °C (+100 °C) (3)
Temperature effect on output (–10 °C to +50 °C) ±0.003% of output / °C
Temperature effect on zero balance (–10 °C to +50 °C) ±0.003% of RO / °C
ELECTRICAL
Input voltage, recommended 5–10 VDC or VAC
Input voltage, maximum 18 VDC or VAC
Input resistance 350 Ω ±5 Ω
Output resistance 350 Ω ±1 Ω
Electrical connection 5 m shielded four conductor cable (5, 10, 20 kN)
10 m shielded four conductor cable (50, 100 kN)
Insulation resistance at 200 VDC > 4 GΩ
MECHANICAL / CONSTRUCTION
Material Stainless steel
Degree of protection IP67
APPROVALS
Certifications ATEX, IECEx certified versions available upon request
NOTES
(1) Referring to recommended loading point
  • Referring to recommended loading point
  • See calibration sheet of the load cell
  • –40 to +100°C on demand

BLH Nobel is continually seeking to improve product quality and performance. Speciications may change accordingly.

상품평

아직 상품평이 없습니다.

“BLH NOBEL / KIS-9 Load Cell/Weigh Module”의 첫 상품평을 남겨주세요