설명
Load Cell Pendeo® Truck Digital weighing technology for reliable vehicle weighing
The digital load cells in the Pendeo® Truck series are specially designed for vehicle weighing. They are designed such that, when combined with mounting kits, they can compensate for movement of the bridge structure. In combination with “DAT – Digital Assistance Technology” from Minebea Intec, the Pendeo® Truck also allows for the recording of valuable data about the weighing process.
Proven Minebea Intec technology for a wide range of applications
- Robust design ensures insensitivity to vibration and enables load capacities from 20 to 75 tonnes.
- Faster commissioning and shorter service times thanks to digital data processing
- High corrosion resistance due to high quality steel alloys ensures extremely long service life
- Perfectly matched weighing electronics complete the digital measurement chain.
Technical specifications
| General technical data for load cell Pendeo® Truck PR 6224B | |||||
| Parameters | Description | Abbr. | C3 | C6 | Unit |
| Accuracy class | 0.015 | 0.008 | %Emax | ||
| Minimal dead load | Lowest limit of specified measuring range | Emin | 0 | %Emax | |
| Maximum capacity | Highest limit of specified measuring range | Emax | 25, 50, 75 | t | |
| Safe load limit | Maximum load possible without irreversible damage | Elim | 25 t, 50 t: 150 75 t: 100 |
%Emax | |
| Destructive load | Danger of mechanical destruction | Ed | 25 t, 50 t: >300 75 t: >200 |
%Emax | |
| Minimum LC verification | Minimum load cell verification interval, vmin = Emax/Y | Y | 14,000 | 20,000 | |
| Deadload output return | Factor for deadload output return after load (DR = 1/2*Emax/Z) | Z | 3,000 | 8,000 | |
| Rated output | Output signal at maximum capacity | Cn | Standardised to Emax in (t) | ||
| Tolerance on rated output | Permissible deviation from rated output | dc | < 0.07 | < 0.07 | %Cn |
| Zero output signal | Load cell output signal under unloaded condition | Smin | 0±1 | 0±1 | %Cn |
| Reproducibility | Max. change of output signal for repeated loading | R | < 0.005 | < 0.005 | %Cn |
| Creep | Max. change of output signal at Emax during 30 min. | dcr | < 0.015 | < 0.008 | %Cn |
| Non-linearity1) | Deviation from best straight line through zero | dLin | < 0.01 | < 0.01 | %Cn |
| Hysteresis1) | Max. difference in between loading and unloading | dhy | < 0.0165 | < 0.008 | %Cn |
| Temperature effect (TK) of Smin | Max. change of Smin in BT | TKSmin | < 0.01 | < 0.007 | %Cn/10 K |
| TK of parameter1) | Max. change of C in BT | TKc | < 0.01 | < 0.005 | %Cn/10 K |
| Insulation impedance | Between measuring circuit and housing at 50 VDC | RIS | > 1,000 × 106 | Ω | |
| Nominal supply voltage range | In compliance with the technical data | BU | 12 to 28 | VDC | |
| Nominal ambient temperature range | In compliance with the technical data | BT | -10 to +40 | °C | |
| Service temperature range | Continuous operation without damage | BTU | -30 to +70 | °C | |
| Storage temperature range | Without electrical and mechanical stress | BTI | -40 to +95 | °C | |
| Marginal eccentricity | Accepted distance from measuring axis | Sex | 5 | mm | |
| Vibration resistance | Resistance against oscillations (IEC 68-2-6-Fc) | 20 g, 100 h, 10 to 150 Hz | |||
| Barometric pressure influence | Barometric pressure influence on the output signal | PKSmin | <420 | g/kPa | |
| Nominal deflection | Max. elastic deforming under maximum capacity | Snom | 25 t: < 0.5 50 t: < 0.8 75 t: <1.1 |
mm | |
| Material (housing) | Stainless steel 1.4301, AISI 304 | ||||
| Protection class | IP66 / IP68 / IP69 (and IP6K6K / IP6K8 / IP6K9K acc. ISO 20653) | ||||
| Cables | Length: 16.5 m Diameter: 5.8 mm Cross section: 4 × 0.35 mm2 Material of cable sheathing: TPE |
||||
| Bending radius | ≥ 30 mm in case of fixed installation ≥ 70 mm in case of flexible installation |
||||
1) The data for non-linearity (dLin), hysteresis (dhy) and temperature effect on C (TKC) are typical values. For OIML R60- or NTEP-approved load cells, the sum of these values is within the permissible cumulative error limits.
| Mounting kits for load cell Pendeo® PR 6224B | |||||
| Maximum capaci- ty of the load cell PR 6224B | Mounting kit/accessories | Material | Description/ comments | Mounting screws | Height (mm) |
| 25 t–75 t | PR 6021/01N | Electrogalvanised steel, chromated and sealed (RoHS-compliant) | Mounting kit incl. Load disc and base component | M12-8.8 | 190.5 |
| PR 6021/03N | Mounting kit incl. Load disc and base component with anti-rotation protection | ||||
| PR 6021/05N | Mounting kit incl. Load disc (turbo load disc) and base component | ||||
| PR 6021/07N | Mounting kit incl. Load disc (turbo load disc) and base component with anti-rotation protection |
||||
| PR 6021/00N | Load disc and base component incl. ground strap | / | / | ||
| PR 6021/02N | Load disc and base component with anti-rotation protection | / | / | ||
| PR 6021/04N | Load disc (turbo load disc) and base component | / | / | ||
| Cable junction box PR 6024 | |
| Parameters | PR 6024/68S |
| Number of load cells | 1 to 8 |
| Material | 1.4404, AISI 316L |
| Protection class | IP66/IP68/IP69 |
| ATEX approval | Zone 2/22 |
| Service temperature range | -30°C to +80°C |
| Service temperature range in explosive atmospheres | -20 °C to +60 °C |
| Storage and transport | -30°C to +80°C |
| Supply voltage | 24 VDC |
| PR 6024/62S power supply unit | |
| Parameters | PR 6024/62S |
| Material | 1.4301, AISI 304 |
| Protection class | IP66/IP68/IP69 |
| ATEX approval | Zone 2/22 |
| Service temperature range | -30°C to +80°C |
| Service temperature range in explosive atmos- pheres | -20 °C to +50 °C |
| Storage and transport | -30°C to +80°C |
| Supply voltage | 100 to 240 VAC ±10%, 50/60 Hz |
| Power consumption | Max. 35 VA |
| Output voltage | 24 VDC |
| Supply and data cable PR 6124 | ||
| Parameters | PR 6124/xxD | PR 6124/xxP |
| Cable type | Data cable | Supply cable |
| Cable diameter | 5.8 mm | 5.2 mm |
| Cable inductance | A/C: 0.5 µH/km A/A: 0.7 µH/km |
/ |
| Bending radius | Fixed installation: 30 mm Repeated bending: 70 mm | Fixed installation: 25 mm Repeated bending: 60 mm |
| Cable capacity | A/C: <110 pF/m A/A: <60 pF/m |
/ |
| Conductivity resistance | ≤ 57 Ω/km | / |
| Temperature range for operation and storage | Operation: -30°C to +90 °C Storage: -40 °C to +90 °C Short term up to +125°C | Operation: -30°C to +90 °C Storage: -40 °C to +90 °C Short term up to +125°C |
| Test voltage | A/C: 800 V A/A: 1,200 V VDE 0472 part 509 test type B |
/ |
| Resistance to oil | VDE 0472 part 803 | VDE 0472 part 803 |
| Resistance to flames | EN 60332 1-2 | EN 60332 1-2 |

All dimensions in mm
| Mounting kits PR 6021 | ||
|
|
PR 6021/05N, ../07N |
|
Cable junction box PR 6024
Cable junction box PR 6024/68S

All dimensions in mm
Ex approval
Scope of validity:
PR 6224B/PR 6024
| Load cell Pendeo® Truck certificates | |||
| Zone | Marking | Certificate number | For |
| 2 | II 3G Ex nA IIC T5 Gc | Manufacturer’s declaration | All PR 6224B/xx PR 6024/6x |
| 22 | II 3D Ex tc IIIC T90 °C Dc | ||
Ordering information
| Load cell Pendeo® Truck (OIML R60, accuracy class C3= 0.015%, C6= 0.008%) | |
| Type | Order number |
| PR 6224B/25t C3 | 940522423325 |
| PR 6224B/25t C6 | 940522426325 |
| PR 6224B/50t C3 | 940522423350 |
| PR 6224B/50t C6 | 940522426350 |
| PR 6224B/75t C3 | 940522423375 |
| PR 6224B/75t C6 | 940522426375 |
| Mounting kits | |
| Type | Order number |
| PR 6021/00N | 940536021001 |
| PR 6021/01N | 940536021011 |
| PR 6021/02N | 940536021021 |
| PR 6021/03N | 940536021031 |
| PR 6021/04N | 940536021041 |
| PR 6021/05N | 940536021051 |
| PR 6021/06N | 940536021061 |
| PR 6021/07N | 940536021071 |
| Cable junction box, power supply | |
| Type | Order number |
| PR 6024/68S | 940536024684 |
| PR 6024/62S | 940536024624 |
| Data and electrical supply cable | |
| Type | Order number |
| PR 6124/01D (1 m) | 940536124013 |
| PR 6124/01P (1 m) | 940536124014 |
| PR 6124/31D (30 m) | 940536124313 |
| PR 6124/ 31P (30 m) | 940536124314 |
| PR 6124/51D (50 m) | 940536124513 |
| PR 6124/51P (50 m) | 940536124514 |
| PR 6124/12D (100 m) | 940536124123 |
| PR 6124/12P (100 m) | 940536124124 |
| PR 6124/15D (150 m) | 940536124153 |
| PR 6124/15P (150 m) | 940536124154 |
| PR 6124/22P (200 m) | 940536124224 |


PR 6021/01N, ../03N