설명
Single Point load cell LC aluminium
Accurate measurement results for scale production
Ideal for integration in bench scales, counting scales and checkweighers: with the LC made from aluminium Single Point load cells, you can rely on the tried-and-tested quality of a leading manufacturer of industrial weighing technology. Suitable for load ranges of 5 kg to 750 kg and a platform size of up to 800 mm × 800 mm.
Verifiable load cells for a variety of industrial applications
- The load cells developed in Germany guarantee accurate weighing results.
All load cells are verifiable according to OIML and NTEP. - Three different models cover a wide range of load levels – from 5 kg up to 750 kg.
- A comprehensive optional portfolio of transmitters, indicators and controllers ensures reliable continu- ous processing of the measurement signals as desired.
- Comprehensive expertise in scale production ensures high-quality advice for individual projects.
Technical specifications
| Parameters | Description | Abbr. | PR 40 C3MR | PR 43 C3MR | PR 47 C3MR | Unit |
| Accuracy class | 0.02 | %Emax | ||||
| Minimum dead load | Lowest limit of specified measuring range | Emin | 0 | %Emax | ||
| Maximum capacity | Highest limit of specified measuring range | Emax | 5 – 50 | 6 – 200 | 100 – 750 | kg |
| Maximum usable load | Upper limit for measurements | Elim | 150 | %Emax | ||
| Destructive load | Danger of mechanical destruction | Ed | 300 | %Emax | ||
| Minimum LC verification | Minimum load cell verification interval, vmin = Emax/Y | Y | 15,000 | |||
| Deadload output return | Factor for deadload output return after load (DR=1/2*Emax/Z) | Z | 3,000 | |||
| Rated output | Relative output at maximum capacity | Cn | 2 | mV/V | ||
| Tolerance on rated output | Permissible deviation from rated output | dc | < 10 | %Cn | ||
| Zero output signal | Load cell output signal under unloaded condition | Smin | 0 ± 5 | %Cn | ||
| Repeatability error | Max. change in load cell output for repeated loading | eR | < 0.0100 | %Cn | ||
| Creep | Max. change of output signal at Emax during 30 min. | dcr | < 0.0166 | %Cn | ||
| Non-linearity1) | Deviation from best straight line through zero | dLin | <0.0166 | %Cn | ||
| Hysteresis1) | Max. difference in LC output between loading and unloading | dhy | <0.0166 | %Cn | ||
| Temperature effect (TK) on Smin | Max. change related to Cn of Smin per 10K in BT | TKSmin | < 0.0093 | %Cn /10K | ||
| Temperature effect (TK) on parameter1) | Max. change related to Cn of C per 10K in BT | TKC | < 0.0117 | %Cn /10K | ||
| Corner load error | 0.0233 | %Cn | ||||
| Input impedance | Between supply terminals | RLC | 380 ± 38 | Ω | ||
| Output impedance | Between measurement terminals | RO | 350 ± 25 | Ω | ||
| Insulation impedance | Between measuring circuit and housing at 100 VDC | RIS | > 5,000 × 106 | Ω | ||
| Nominal supply voltage range | To hold the specified performance | Bu | ≤12 | V | ||
| Max. supply voltage | Continuous operation without damage | Umax | 15 | V | ||
| Nominal ambient temp. range | To hold the specified performance | BT | -10 to +40 | °C | ||
| Usable ambient temp. range | Continuous operation without damage | BTU | -20 to +65 | °C | ||
| Storage temperature range | Without electrical and mechanical stress | BTi | -25 to +70 | °C | ||
| Barometric pressure influence | Influence of barometric pressure on output | < 0.007 | < 0.007 | < 0.007 | %Cn /kPa | |
| Nominal deflection | Max. elastic deformation under maximum capacity | Snom | < 0.55 | < 0.5 | mm | |
| Cable length | 0.5 | 3 | m | |||
| Material | Aluminium | |||||
|
Max. platform size |
In compliance with the technical data according to OIML R76 |
350 × 350 |
450 × 450 for Emax = 15 to 30 kg 600 × 600 for Emax = 50 to 100 kg |
800 × 800 |
mm × mm |
|
| IP protection class | According to EN 60529: IP66 + IP67 | |||||
1) The data for non-linearity (dLin), hysteresis (dhy) and temperature effect on C (TKC) are typical values. For OIML R60 or NTEP approved load cells, the sum of these values is within the permissible cumulative error limits.
| Accuracy classes and minimum verification interval, vmin – PR 40 | ||||||||||
| Capacity | Maximum number of verification intervals, nmax | 5 kg | 7,5 kg | 10 kg | 15 kg | 20 kg | 30 kg | 40 kg | 50 kg | |
| C3MR | 3000 | 0,34 | 0,50 | 0,67 | 1,00 | 1,34 | 2,00 | 2,67 | 3,34 | g |
| NTEP III 5000 Single | 5000 | 0,34 | 0,50 | 0,67 | 1,00 | 1,34 | 2,00 | 2,67 | 3,34 | g |
| Accuracy classes and minimum verification interval, vmin – PR 43 | |||||||||||
| Capacity | Maximum number of verification intervals, nmax | 6 kg | 10 kg | 15 kg | 20 kg | 30 kg | 50 kg | 75 kg | 100 kg | 200 kg | |
| C3MR | 3000 | 0,40 | 0,67 | 1,00 | 1,34 | 2,00 | 3,34 | 5,00 | 6,67 | 13,34 | g |
| NTEP III 5000 Single | 5000 | 0,40 | 0,67 | 1,00 | 1,34 | 2,00 | 3,34 | 5,00 | 6,67 | 13,34 | g |
| Accuracy classes and minimum verification interval, vmin – PR 47 | |||||||||
| Capacity | Maximum number of verification intervals, nmax | 100 kg | 150 kg | 200 kg | 250 kg | 300 kg | 500 kg | 750 kg | |
| C3MR | 3000 | 6,67 | 10,00 | 13,34 | 16,67 | 20,00 | 33,34 | 50,00 | g |
| NTEP III 5000 Single | 5000 | 6,67 | 10,00 | 13,34 | 16,67 | 20,00 | 33,34 | 50,00 | g |

Technical diagrams
Single Point load cell LC – PR 40

Single Point load cell LC – PR 43

Single Point load cell LC – PR 47

Ex approval
Scope of validity:
Single Point load cell LC aluminium
| Certificates for Single Point load cell LC aluminium | |||
| Zone | Marking | Certificate number | For |
| 0 and 1 | II 1G Ex ia IIC T6/T4 Ga |
BVS 21 ATEX E 023 X IECEx BVS 21.0024X |
PR 4x/xx E only |
| 20 | II 1D Ex ia IIIC T200165°C Da | ||
| 2 | II 3G Ex ec IIC T6/T4 Gc |
All PR 4x without E |
|
Ordering information
| Single Point Wägezelle LC – PR 40 | |
| Typ | Order number |
| PR 40/5 kg C3MR | 9409 240 07005 |
| PR 40/7,5 kg C3MR | 9409 240 07007 |
| PR 40/10 kg C3MR | 9409 240 07010 |
| PR 40/15 kg C3MR | 9409 240 07015 |
| PR 40/20 kg C3MR | 9409 240 07020 |
| PR 40/30 kg C3MR | 9409 240 07030 |
| PR 40/40 kg C3MR | 9409 240 07040 |
| PR 40/50 kg C3MR | 9409 240 07050 |
| Single Point load cell LC – PR 43 | |
| Typ | Order number |
| PR 43/6 kg C3MR | 9409 243 07006 |
| PR 43/10 kg C3MR | 9409 243 07010 |
| PR 43/15 kg C3MR | 9409 243 07015 |
| PR 43/20 kg C3MR | 9409 243 07020 |
| PR 43/30 kg C3MR | 9409 243 07030 |
| PR 43/50 kg C3MR | 9409 243 07050 |
| PR 43/75 kg C3MR | 9409 243 07075 |
| PR 43/100 kg C3MR | 9409 2430 7110 |
| PR 43/200 kg C3MR | 9409 2430 7120 |
| Other accuracy classes and EX | |
| Typ | Order number |
| PR 4x/xx kg C6 | 9409 24x 06xxx |
| PR 4x/xx kg III 5000 S | 9409 24x 0Cxxx |
| PR 4x/xx kg C3MRE | 9409 64x 07xxx |
| PR 4x/xx kg C6E | 9409 64x 06xxx |
| Single Point load cell LC – PR 47 | |
| Type | Order number |
| PR 47/100 kg C3MR | 9409 247 07110 |
| PR 47/150 kg C3MR | 9409 247 07115 |
| PR 47/200 kg C3MR | 9409 247 07120 |
| PR 47/250 kg C3MR | 9409 247 07125 |
| PR 47/300 kg C3MR | 9409 247 07130 |
| PR 47/500 kg C3MR | 9409 247 07150 |
| PR 47/750 kg C3MR | 9409 247 07175 |



상품평