WIKA / Model F4822 Load cell For mobile elevating work platforms

Applications
  • Overload protection in mobile elevating work platforms
  • Industry
  • Logistics sector
  • Facility cleaning and maintenance
  • Energy utilities in indoor and outdoor areas
Special features
  • Measuring ranges 0 … 2,000 kg [0 … 4,409 lb]
  • Diverse redundant electronics
  • Easy mounting by means of a defined hole pattern
  • Special protective circuit for high EMC
  • Fatigue-proof measuring body
Category:
브랜드:

설명

Model F4822 Load cell For mobile elevating work platforms

Fatigue-proof measuring body
The model F4822 load cell for mobile elevating work platforms (MEWP) is designed for static and dynamic measuring requirements in both tension and compression force direction.
It is made from coated aluminium, which has particularly suitable properties for overload protection in mobile elevating work platforms.

Diverse redundant electronics
Due two redundant, opposing channels, the model F4822 ensures precise and reliable load monitoring of the cages of mobile elevating work platforms.

Special protective circuit for high EMC (electromagnetic compatibility)
Through a special protective circuit, harmful high electrical voltages, which can occur in electromagnetic instruments through self-induction, are limited and the voltage rise rate
is reduced. This contributes to the increase of reliability, service life and immunity – EMC – and reduction of emitted interference. Its safe operation is crucial for the safety of personnel and machinery.

The model F4822 load cell enables carefree use of mobile elevating work platforms in the industry, logistics sector, facility cleaning and maintenance in public spaces as well as for energy utilities and buildings in indoor and outdoor areas.

The measured force is output as a diverse redundant opposing electrical output signal (4 … 20 mA/20 … 4 mA, 3-wire) to reduce possible sources of errors to an absolute minimum.

Depending on the application, corresponding technical and regional approvals are available.

Technical data

Basic information / Version per standard
Standard In accordance with directive VDI/VDE/DKD 2638
Material of the measuring body Aluminium
Ingress protection (per IEC/EN 60529) IP67 and IP69K
Screw quality 10.9 / M16 x 1.5 galvanized or chromated
Weight Approx. 4 kg [8.82 lb]
Measuring element / Measurement principle / Sensor element
Type of measuring element Measuring spring (aluminium) with strain gauges
Force introduction Compression force
Accuracy specifications / Repeatability
Relative linearity error dlin ≤ 0.5 % Fnom
Influence of torque on the measuring signal ≤ 10 % Fnom
Temperature effect on zero signal TC0 ≤ ± 0.2 % Fnom/10 K
Temperature effect on characteristic value TCC ≤ ± 0.2 % Fnom/10 K
Reference conditions
Load ■ ≤ (UB – 10 V) / 0.02 A (channel 1) ■ ≤ (UB – 7 V) / 0.02 A (channel 2)
Rated load Fnom
kg lb
2,000 4,409
Further information to rated load Fnom
Force limit FL → See chapter „Work load limit (WLL)“
Breaking force FB → See chapter „Work load limit (WLL)“
Output signal
Rated characteristic value Cnom 4 … 20 mA /20 … 4 mA, 3-wire, diverse redundant opposing
Auxiliary power
Supply voltage UB DC 9 … 32 V
Current/power consumption Voltage output: < 8 mA per channel
Time response/Dynamic behaviour
Response time < 2 ms (within 10 % … 90 % Fnom) → Further response times on request
Voltage supply and performance data
Electrical safety Reverse polarity and surge protection and short-circuit resistance
Electrical connection
Connection type Cable outlet, flying leads
Cable diameter 6.6 mm [0.260 in]
Cable length 3 m [9.84 ft]
Insulation resistance Ris > 2 GΩ / 100 V
Material PUR

Pin assignment
Electrical connection: cable outlet, flying lead
Output signal: 4 … 20 mA/20 … 4 mA, 3-wire, diverse redundant opposing

Signal channel Cable colour
UB(CH1) Sensor voltage supply (+) 1 Brown
UB(CH2) Sensor voltage supply (+) 2 White
0 V/S– (CH1) 0-V-potential/output signal (-) 1 Green
0 V/S– (CH2) 0-V-potential/output signal (-) 2 Grey
S(CH1) Output signal (+) 1 Yellow
S(CH2) Output signal (+) 2 Pink
Shield Grounding Green-yellow
Operating conditions
Rated temperature range BT, nom -20 … +80 °C [-4 … +176 °F]
Operating temperature range BT, G -40 … +80 °C [-40 … +176 °F]
Storage temperature range BT, S -40 … +85 °C [-40 … +185 °F]
Humidity 35 … 85 % relative humidity (non-condensing)
Vibration resistance Frb (per DIN 50100) 50 % Fnom
Operating altitude Up to 2,500 m [6,562 ft] above sea level
Pollution degree in accordance with UL certification Degree 4: “Electrical equipment for outdoor use”
Packaging and instrument labelling
Packaging ■ Individual packaging ■ Multiple packaging (up to 20 pieces possible)
Instrument labelling (product label) ■ WIKA product label, glued ■ Customer-specific product label on request

Work load limit (WLL)
The instrument‘s permissible working load was determined based on the safety against breaking load. A factor of 2 was assumed for this, meaning that the equivalent stress in the critical cross-section is at most half the tensile strength of the material.
This results in the WLL as follows: