설명
Model F1101 Hydraulic compression force transducer
Closing force test instrument up to 36 kN
The hydraulic force transducer model F1101 is used in applications with little mounting space to easily capture and display forces. The very small dimensions allow for installation even in applications with limited mounting space.
The hydraulic transducer is especially suited to measuring compression forces exerted during the closing of automatic doors and gates or similar bodies. Hydraulic force measurement is a simple way to capture and display the forces occurring in various applications.
The force measurement is made using the principle of hydraulics: The force acting on a piston leads to a pressure increase which can be visualised on a connected display instrument. The scale of the display instrument can be defined in various units (e.g. N, kN, kg, t).
Leak-tightness warranty
The warranty on leak tightness of the hydraulic force measuring unit was extended to 5 years. A force transducer that starts to leak within this period will be repaired free of charge.
Use of the force measuring unit as intended is a prerequisite for the extended 5-year warranty.
Specifications per VDI/VDE/DKD 2638
| Model F1101 | |
| Rated force Fnom | 0 … 100 N to 0 … 36 kN |
| Nominal size | NS 6 |
|
Display |
Pressure gauge 213.40 (NS 63) Digital pressure gauge DG-10 Pressure sensor (on request) |
| Relative linearity error dlin ■ Standard ■ Option |
≤ ±1.6 % Fnom (analogue display)1) ≤ ±0.5 % Fnom (pressure sensor/digital pressure gauge)1) |
| Limit force FL | 100 % Fnom |
| Breaking force FB | > 130 % Fnom |
| Rated displacement snom | < 0.5 mm |
| Rated temperature range BT, nom | -25 … +50 °C |
| Ingress protection (per EN/IEC 60529) | IP65 |
| Case | Stainless steel |
| Piston | Stainless steel |
| Mounting type ■ Standard ■ Option |
Adapter L = 50 mm Capillary Measuring hose for “separation without any losses” |
| Fill fluid | Glycerine/water 70 %/30 % |
| Weight in kg ■ with pressure gauge 213.40 (NS 63) ■ with digital pressure gauge DG-10 |
0.6 1 |
1) For rated forces below 500 N, the relative linearity error is ±1.6 % Fnom for all connected measuring instruments.
Dimensions in mm

| Version | Display | Options | ||||
| Rated force | System pressure | 213.40 | DG-10 | Measuring hose DN2 [max. L 1)] | Capillary [max. L 1)] | |
| N/kN | bar | m | ||||
| 100 | N | 1.6 | n | – | – | – |
| 160 | 2.5 | n | – | – | – | |
| 250 | 4 | n | – | – | 1.0 | |
| 400 | 6 | n | – | 0.5 | 1.0 | |
| 600 | 10 | n | – | 1.0 | 2.0 | |
| 1 | kN | 16 | n | – | 1.0 | 2.0 |
| 1.2 | 20 | – | n 2) | 1.5 | 2.0 | |
| 1.6 | 25 | n | – | 1.5 | 2.0 | |
| 2.5 | 40 | n | – | 1.5 | 2.0 | |
| 3.2 | 50 | – | n | 2.0 | 2.0 | |
| 4 | 60 | n | – | 2.0 | 2.0 | |
| 6 | 100 | n | n | 2.0 | 2.0 | |
| 10 | 160 | n | n | 2.0 | 4.0 | |
| 16 | 250 | n | n | 3.2 | 4.0 | |
| 20 | 315 | n | – | 3.2 | 4.0 | |
| 25 | 400 | n | n | 3.2 | 6.0 | |
| 36 | 600 | n | n | 3.2 | 6.0 | |
| Other rated loads and versions on request | ||||||
= possible selection
1) For a rated force below 500 N, the relative linearity error is ±1.6 % Fnom for all connected measuring instruments.
2) Relative linearity error < ±1.0 % Fnom