WIKA / Model F5802 Load pin

Applications
  • Crane systems and hoists
  • Industrial weighing technology
  • Machine building and plant construction
  • Manufacturing automation
Special features
  • Measuring ranges 20 … 10,000 kN [204 tf … 101,972 tf]
  • Corrosion-resistant stainless steel version
  • Existing non-measuring bolts are simply replaced by the load pins
  • For overload protection in cranes and hoists
  • Good reproducibility, easy installation
Category:
브랜드:

설명

Model F5802 Load pin

Rated force up to 10,000 kN

Load pins of the model F5802 are suitable for static and dynamic measuring tasks as a replacement for non-measuring bolts. They serve for determining tension and / or compression forces under harsh operating conditions.

The load pins are very often used in hoists and crane systems, e.g. used in construction cranes or in port and offshore cranes, as well as in the field of industrial weighing technology and special machine construction. There they are installed in particular in deflection pulleys, cable winches, fork or roller bearings.

Load pins of this model serve as reliable overload protection in mechanical and plant engineering.

The corresponding technical and regional approvals of these force transducers are, of course, available as options.

The load pins are made of high-strength, corrosion resistant 1.4542 stainless steel, the properties of which are ideal for the application areas.

As output signals, the common active current and voltage outputs are available (4 … 20 mA, 0 … 10 V).

Redundant output signals and CANopen® protocols are also possible.

Technical data in accordance with VDI/VDE/DKD 2638

Model F5802
Rated force Fnom kN [tf] 20 … 10,000 [204 … 101,972]
Relative linearity error dlin dlin1) 0.5 % … 1 % Fnom
Relative Umkehrspanne v 0.5 % … 1 % Fnom
Relative repeatability error in unchanged mounting position brg 0.5 % … 1 % Fnom
Temperature effect on
characteristic value TKC 0.2 % Fnom /10 K
zero signal TK0 0.2 % Fnom /10 K
Force limit FL 150 % Fnom
Breaking force FB 300 % Fnom
Material of measuring device Corrosion-resistant stainless steel
Rated temperature BT, nom -10 … +40 °C [14 … +104 °F]
Operating temperature BT, G -20 … +80 °C [-4 … +176 °F]
Electrical connection M12 x 1, 4-pin or 5-pin
Output signal (rated output) Cnom ■ 4 … 20 mA, 2-wire
■ 4 … 20 mA, 3-wire
■ 2 x 4 … 20 mA, redundant
■ DC 0 … 10 V, 3-wire
■ 2 x DC 0 … 10 V redundant
■ 1 … 2 mV/V
■ CANopen® Protocol in accordance with CiA®301, device profile CiA®404, communication services LSS (CiA®305), configuration of the instrument address and baud rate Sync/Async, Node/ Lifeguarding, heartbeat; zero and span ±10 % adjustable via entries in the object directory 2)
Input resistance Re 750 ± 30 Ω
Output resistance Ra 700 ± 5 Ω
Isulation resistance RiS ≥ 5,000 MΩ
Supply voltage UB ■ DC 9 … 36 V for current output
■ DC 13 … 36 V for voltage output
■ DC 5 … 10 V for mV/V
■ DC 9 … 36 V for CANopen®
Ingress protection (acc. to IEC/EN 60529) IP67

1) Relative linearity error accordance with VDI/VDE/DKD 2638 chapter 3.2.6.
2) Protocol in accordance with CiA®301, device profile CiA®404, communication service LSS (CiA®305)
CANopen® and CiA® are registered community trademarks of CAN® in Automation e. V.

Dimensions/mounting situation of the load pin

Exemplary illustration.
Dimensioning: The customer-specific load pin drawing of the respective order number has priority.

Pin assignment cable

Electrical connection
Supply voltage + Exc+ Red
Supply voltage – Exc- Black
Signal + Sig+ Green
Signal – Sig- White
Shield Shield Yellow-green