AEP transducers / KAL / Force transducers

Force transducer suitable for the calibration of material testing machines and metrological comparisons between laboratories.
Excellent metrological features stated by the Metrological Research National Institute (I.N.RI.M.).
High stability given by monolithic structure.
Structure optimization thanks to the F.E.M. design.
Off-center loads compensation ±0.005% F.S.
Low sensitivity to supporting surfaces ±0.002% F.S.
Easy application for tension and compression.
Easy to handle thanks to its light weight (1MN about 36kg).

Category:

설명

Force transducers for the measurement of static and dynamic loads in COMPRESSION and TENSION.

Nominal Load from 10 kN to 2 MN
Class (ISO 376) 00, 0.5 and 1
Linearity and Hysteresis 0,03%
Output: 2mV/V

• Excellent metrological features stated by the Metrological Research National Institute (I.N.RI.M.).
• High stability given by monolithic structure.
• Structure optimization thanks to the F.E.M. design.
• Off-center loads compensation  ≤0.005% F.S.
• Low sensitivity to supporting surfaces  ≤0.002% F.S.
• Easy application for tension and compression.
• Easy to handle thanks to its light weight (2MN ~48kg).

Dimensions[mm]

KAL: A ÆB C D ÆE F ÆG H I L N P
5, 10, 25, 50 kN 142 65 25 40 57 M30×2 50 33 33 10 133 ~ 295
100 kN 182 166 ~ 380
200 kN 203 100 34 48 76 M42×3 62 42 42 10 187 ~ 400
300 kN 209 193 ~ 498
500 kN 272 269
750 kN 294 127 50 60 100 M80×2 100 72 72 20 291 /
1000 kN 297 294
2000 kN 364 145 57 68 127 M100×3 123.5 95 80 20 357 /
CODE (class 00) CODE (class 0.5) CODE (class 1) LOAD A B C D ØE ØF G H L M N Q P R
CKAL12710KN005 CKAL12710KN055 CKAL12710KN15 10 kN 152 127 / / 84 61 M42×3 92 33 10 R65 M30X2 1.5 20
CKAL12725KN005 CKAL12725KN055 CKAL12725KN15 25 kN
CKAL12750KN005 CKAL12750KN055 CKAL12750KN15 50 kN
CKAL165100KN005 CKAL165100KN055 CKAL165100KN15 100 kN 190 165 / / 112 71 M56×3 115 / 136 / 142 43 12 R160 M42X3 1.5 32
CKAL165200KN005 CKAL165200KN055 CKAL165200KN15 200 kN
CKAL165300KN005 CKAL165300KN055 CKAL165300KN15 300 kN
CKAL230500KN005 CKAL230500KN055 CKAL230500KN15 500 kN 255 230 24 M12 162 101 M80×2 179 / 201 / 204 72 15 R300 M80X2 3 46
CKAL230750KN005 CKAL230750KN055 CKAL230750KN15 750 kN
CKAL2301MN005 CKAL2301MN055 CKAL2301MN15 1000 kN
CKAL2302MN055 CKAL2302MN15 2000 kN 269 230 10 M8 165 125 M100×3 260 95 26 R200 M100×3 3 65

(1) ACCREDIA certification can NOT be performed by LAT 00120 Laboratory, on request it can be ordered to other Accredited Laboratories.

The transducers belonging to these series distinguish themselves for their excellent metrological characteristics, long-term stability and insensitivity to off-center loads.
Born from the need of estimating the uncertainties among force sample machines of ACCREDIA centers and national samples, these dynamometers are nowadays used as first line or transfer samples among laboratories, research bodies and companies working according to Quality standards. Thanks to their compact size and easy installation, they are applied as reference system, on force sampling machines, materials testing machines and test benches.

Technical Data

Accuracy class ISO 376 00 0.5 1
NOMINAL LOAD 10-25-50-100-200-300-500-750-1000 kN
2000 kN
RELATIVE ERROR (at reading)
a) repeatability 0°-120°-240° (b)
b) interpolation (fc)
c) reversibility (u)
d) zero (fo)
≤±0.020%(1)
≤±0.020%(1)
≤±0.030%(1)
±0.005% F.S.
≤±0.045%(1)
≤±0.040%(1)
≤±0.050%(1)
≤±0.010% F.S.
≤±0.080%(1)
≤±0.050%(1)
≤±0.090%(1)
≤±0.010% F.S.
LINEARITY
HYSTERESIS
≤±0.02% F.S. 2000kN: ≤±0.05%
≤±0.02% F.S. 2000kN: ≤±0.05%
TEMPERATURE EFFECT (10°C)
a) on zero
b) on sensitivity
≤±0.015% F.S.
≤±0.010% F.S.
NOMINAL SENSITIVITY SENSIVITY TOLERANCE 2mV/V
≤±0.1% F.S.
NOMINAL LOAD INPUT RESISTANCE OUTPUT RESISTANCE 10-25-50 kN
700±2Ω
705±2Ω
NOMINAL LOAD INPUT RESISTANCE OUTPUT RESISTANCE 100-200-300-500-750-1000-2000 kN
350±2Ω
352±2Ω
INSULATION RESISTANCE
ZERO BALANCE

RECOMMENDED SUPPLY VOLTAGE
NOMINAL SUPPLY VOLTAGE
MAXIMUM SUPPLY VOLTAGE
> 5 GW
±0.2 % F.S.
10 V
1-15 V
18 V
MECHANICAL LIMIT VALUES REFERRED TO NOMINAL LOAD:
a) service load
b) max permissible load
c) breaking load
d) max transverse load
e) max permissible dynamic load
DISPLACEMENT AT NOMINAL LOAD
120%
150%
>300%
100%
75%
~0.2 mm 2000kN: ~0.35mm
REFERENCE TEMPERATURE
TEMPERATURE NOMINAL RANGE
SERVICE TEMPERATURE
STORAGE TEMPERATURE
+23°C
-10/+40°C
-10/+70°C
-20/+80°C
WEIGHT
PROTECTION CLASS (EN 60529)
EXECUTION MATERIAL

CABLE LENGTH
~4.5 – 48 kg
IP67
Acciaio Inox / Stainless Steel
5 m

(1) Percentuale errors referred to reading, min. 1/10 of the nominal load.
(2)Tests and calibrations performed in COMPRESSION.
kg calibrations on request.
Classifications according ASTM E74 on request.

Electrical Connections

PVC 105°C shielded cable, Ø 5.2mm with 6 tinned Ø 0.25mm2 conductors.

*Connected to the body of the transducer

 

 