설명
WAS Stainless steel force sasher/ through hole load cell
Key features
- Stainless steel construction (17-4PH)
- Ranges from 12.5 to 540 kN
- Environmentally sealed to IP66
- Optional ATEX versions for hazardous areas
- High overload capability (150%)
- Custom sizes and ranges available
About the WAS Stainless steel force washer
he WAS series is a robust and compact load cell range designed for through-hole applications. It ensures accurate force measurement in both tension and compression directions, with high overload tolerance up to 150% of the rated load. The stainless steel 17-4PH construction guarantees durability even in harsh environments.
Usage conditions
Operating reliably in temperatures from -20°C to +70°C, the WAS series offers protection to IP66 (optionally IP67). It supports ATEX-certified versions for hazardous areas, both intrinsically safe (Ex i) and explosion-proof (Ex d), making it suitable for critical applications in industrial zones.
Possible applications
- Bolt tension monitoring
- Forklift overload protection
- Press tool force measurement
- Tie rod or anchor point tension control
- Failsafe cable tensioning
Advantages of choosing this product
The WAS load cell offers precision and flexibility in one compact design. With a wide range of standard capacities and the possibility of customization, it can be tailored to unique application needs. LCM Systems’ expertise also ensures integration with complete measurement systems, reducing time-to-deploy.
Other important features
- Bridge resistance: 700Ω
- Excitation voltage: 10 VDC recommended
- Repeatability: ±1% max
- Zero offset: <±5% of rated load
- Temperature compensation range: -10 to +5
- Custom sizes & outputs on request
Technical Specifications
| Specification | Value |
|---|---|
| Range (kN) | 12.5, 25, 35, 50, 100, 160, 200, 250, 300, 360, 540 |
| Maximum overload range | 150% of rated load |
| Output sensitivity | 1.5mV/V nominal |
| Zero offset | <±5% of rated load |
| Linearity | <±1.5% of rated load (between 50% and 100% of rated load) |
| Repeatability | <±1% (if mounting position remains unchanged)<±10% (if mounting position is changed) |
| Excitation voltage | 10vdc recommended, 15vdc maximum |
| Bridge resistance | 700Ω |
| Insulation resistance | >500MΩ @ 100vdc |
| Operating temperature range | -20 to +70°C (-20 to +55°C for Ex d) |
| Compensated temperature range | -10 to +50°C |
| Zero temperature coefficient | <±0.03% of rated load/°C (<±0.01% of rated load/°C optional |
| Span temperature coefficient | <±0.03% of rated load/°C (<±0.01% of rated load/°C optional) |
| ATEX certification details Ex i / Ex d | II 2G Ex ib IIC T4 Gb / II 2D Ex ib IIIC T135°C DbII 2G Ex d IIC T6 Gb / II 2D Ex tb IIIC T85°C Db |
| Environmental protection level | IP66 (IP67 optional) |
| Connection type | 2 metre long 4-core PVC cable, exiting via cable gland |
| Wiring connections | +ve supply: Red -ve supply: excitation: Blue+ve signal: Green -ve signal: excitation: Yellow |


상품평